Performance of High Temperature Filter System for Radioactive Waste Vitrification Plant

방사성폐기물 유리화 플랜트 고온여과시스템의 성능 특성

  • Published : 2004.09.01

Abstract

Important operation parameters and performance of a high temperature ceramic candle filter system were evaluated through a series of demonstration tests at a pilot-scale vitrification plant. At the initial period of each test, due to the growth of dust cake on the surface of ceramic candles, the pressure drop across the filter media increased sharply. After that it became stable to a certain range and varied continuously proportion to the face velocity of off-gas. On the contrary, at the initial period of each test, the permeability of filter element decreased rapidly and then it became stable. Back flushing of the filter system was effective under the back flushing air pressure range of 3∼5 bar. Based on the dust concentrations measured by iso-kinetic dust sampling at the inlet and outlet point of HTF, the dust collection efficiency of HTF evaluated. The result met the designed performance value of 99.9%. During the demonstration tests including a hundred hour long test, no specific failure or problem affecting the performance of HTF system were observed.

파일럿 규모의 유리화플랜트에서 일련의 시험을 통해 고온 세라믹 캔들 필터 시스템의 주요 운전 변수 및 성능을 평가하였다. 실증 시험결과 매 시험초기에는 필터 표면 먼지층(Dust cake)의 생성으로 인해 필터 매질에 걸리는 차압이 급격히 상승하였다. 그런 다음 차압은 곧 일정한 범위에서 안정되었고, 표면유속(Face velocity)에 비례하여 계속적으로 변화하였다. 이와 반대로, 필터 투과율(Permeability)은 매시험 초기에 급격히 감소하였다. 필터표면 먼지의 역세정은 공기압 3~5 bar범위 일때 효율적이었다. 필터 입구 및 출구에서 동시에 등속으로 채취한 먼지농도를 바탕으로 필터의 먼지 포집율(Dust collection efficiency)을 평가한 결과 필터 성능은 설계값인 99.9%과 같은 것으로 나타났다. 100시간의 장기시험을 포함한 일련의 실증시험을 수행하는 동안 고온 필터 시스템의 성능에 영향을 주는 특별한 문제점은 발견되지 않았다.