Comparative Biocompatibility of Metal Implants in Connective Tissue of Abdominal Wall of the Mouse

마우스의 복벽에서 결합조직에 대한 금속 이식체의 생체적합성 비교

  • 김국렬 (순천대학교 자연대학 생물학과) ;
  • 이민호 (전북대학교 치과대학 재료학교실) ;
  • 김병일 (순천대학교 공과대학 금속재료공학과) ;
  • 민병운 (광양보건대학 임상병리학과) ;
  • 김명훈 (광주보건대학 물리치료과) ;
  • 최은상 (부사대학교 생명과학부) ;
  • 조현욱 (순천대학교 자연대학 생물학과)
  • Published : 2004.03.01

Abstract

The purpose of this study is to compare the biocompatibility of commercial purity Ti, Ti-6AI-4V and Ti-6AI-7Nb alloy specimens with and without surface treatment in mouse abdominal connective tissue in vivo. Each metal was implanted into specific abdominal subdermal tissue site of female mouse. After 4 weeks, the implants were removed and abdominal tissues were fixed, dehydrated and embedded in glycol methacrylate resin. And the tissues were histologically prepared for microscopical evaluation. It was characterized by the presence of connective tissue with fibrous capsule surrounding the implant. The fibrous tissue surrounding the implant was studied to determine the biocompatibility of implanted metals. The average thickness of the fibrous capsule formed around the implant was much thinner for the hydrogen peroxide added hydrochloric acid solution-treated specimen than for the others. The results of this evaluation indicate that modification of the surface properties of titanium and titanium alloy implants changes the biological properties in the abdominal connective tissue. In conclusion, these observations suggest that the proper surface treatment performed in the study is effective for the improvement of biocompatibility.

Keywords

References

  1. Benghuzzi, H. (1996): Cytological evaluation of capsular tis-sue surrounding TCPL implant in adult rats. Biomed. Sci. Instrum., 32, 81-86
  2. Butler, K., Benghuzzi, H. and Puckett, A. (2001a): Cytologi-cal evaluation of the tissue-implant reaction associated with S/C and l/P implantation of ALCAP and HA bioceramics in vivo. Pathol. Res. Pract., 197, 29-39
  3. Butler, K., Benghuzzi, H. and Puckett, A. (2001b): Morpho-metric evaluation of tissue-implant reaction associated with ALCAP and TCP bioceramics in vivo. J. Invest. Surg., 14, 139-152
  4. Butler, K., Benghuzzi, H. and Tucci, S. (2001c): Tissue-implant response following soft tissue implantation of poly-L-lysine coated UHMW-polyethylene into adult male rats. Biomed. Sci. Instrum., 37, 19-24
  5. Butler, K., Benghuzzi, H., Tucci, M. and Cason, Z. (1997): A comparison of fibrous tissue formation surrounding intrap-eritoneal and subcutaneous implantation of ALCAP, HA, and TCP ceramic devices. Biomed. Sci. Instrum., 34, 1823
  6. Gotman, I. (1997): Characteristics of metals used in implants. J. Endoural., 11, 383-389 https://doi.org/10.1089/end.1997.11.383
  7. Groot, KD. (1991): Medical applications of calciumphos-phate bioceramics. J. Ceram. Soc. Japan, 99, 943-953
  8. Groot, KD., Geesink, R.G.T., Klein, C.P.A.T. and Serekian, P. (1987): Plasma-sprayed coating of hydroxyapatite. J. Biomed. Mater. Res., 21, 1357-1387
  9. Hanawa, T., Asami, K. and Asaoka, K. (1996): Microdissolu-tion of calcium ions from calcium-ion-implanted titanium. Corros. Sci., 38, 1579-1594
  10. Holgers, K.M., Thomsen, P., Tjellstrom, A. and Ericson, L.E. (1995): Electron microscopic observation on the soft tissue around clinical long-term percutaneous titanium implants. Biomaterials, 16, 83-90 https://doi.org/10.1016/0142-9612(95)98267-I
  11. Jansen, J.A., Dhert, W.J., van der Waerden, J.P. and von Recum, A.F. (1994): Semi-quantitative qualitative histologic analysis method for the evaluation of implant bio-compatibility. J. Invest. Surg., 7, 123-134 https://doi.org/10.3109/08941939409015356
  12. Johnson, R., Harrison, D., Tucci, M., Tsao, A., Lemos, M., Puckett, A., Hughes, J.L. and Benghuzzi, H. (1997): Fibrous capsule formation in response to ultra high molecular weight polyethylene treated with peptides that influence adhesion. Biomed. Sci. Instrum., 34, 47-52
  13. Kim, B.I., Lee, M.H., Chon, W.Y., Yoon, D.J., Bae, T.S., Park, H.H. and Cho, H.W. (2001): Biocompatibility of surface-treated pure titanium and Ti-6AI-4V alloy. Materials Transactions, 42, 2590-2596
  14. Kokubo, T. (1991): Recent progress in glass-based materials for biomedical application. J. Ceram. Soc. Japan, 99, 965973
  15. Kokubo, T, Mijaji, F., Kim, H.M. and Nakamura, T. (1996): Spontaneous apatite formation on chemically surface treated Ti. J. Am. Ceram. Soc., 79, 1127-1129 https://doi.org/10.1111/j.1151-2916.1996.tb08561.x
  16. Li, P., Ohtsuki, C., Kokubo, T, Nakanishi, K., Soga, N. and Groot, K.D. (1994): The role of hydrated silica, titania and alumina in inducing apatite on implants. J. Biomed. Mater. Res., 28, 7-15 https://doi.org/10.1002/jbm.820280103
  17. Mery, C.C., Grunert, G., Plaza, J.C. and Pizzi, T. (1996): Ultrasound characteristics of connective tissue around porous hydroxyapatite implants in rats. Biol. Res., 29, 361-367
  18. Morehead, J.M. and Holt, G.R. (1994): Soft-tissue response to synthetic biomaterials. Otolaryngol. Clin. North. Am., 27, 195-201
  19. Salthouse, T.N. (1984): Some aspects of macrophage behavior at the implant interface. J. Biomed. Mater. Res., 18, 395-401 https://doi.org/10.1002/jbm.820180407
  20. Schreiber, H., Keller, E, Kinzl, H.P., Hunger, H., Knofler, W, Rubling, U. and Merten, W (1990a): The question of the transmissibility of the result of subcutaneous tests of bio-materials from animals to humans. Z. Exp. Chir. Trans-plant Kunstliche Organe, 23, 23-25
  21. Schreiber, H., Kinzl, H.P. and Thieme, J. (1990b): Computer-ized microscopic image analysis method in tissue-bioma-terials interaction. Biomater. Artif. Cells Artif. Organs, 18, 637-641
  22. Shannon, C., Thull, R. and von Recum, A. (1997): Types I and III collagen in the tissue capsules of titanium and stainless-steel implants. J. Biomed. Mater. Res., 34, 401-408 https://doi.org/10.1002/(SICI)1097-4636(19970305)34:3<401::AID-JBM15>3.0.CO;2-I
  23. Tang, L. and Eaton, J.W. (1995): Inflammatory response to biomaterials. Am. J. Clin. Pathol., 103, 466-471
  24. Tengvall, P., Elwing, H. and Lundstrom, I. (1989): Titanium gel made from metallic titanium and hydrogen peroxide. J. Colloid. Interlace Sci., 130,405-413 https://doi.org/10.1016/0021-9797(89)90117-3
  25. Thomsen, P. and Gretzer, C. (2001): Macrophage interactions with modified material surfaces. Current Opinion Solid State and Materials Sci., 5, 163-176
  26. Turner, R.F., Harrison, D.J. and Rajotte, R.V. (1991): Prelimi-nary in vivo biocompatibility studies on perfluorosulphonic acid polymer membranes for biosensors applications. Bio-materials, 12, 361-368
  27. van Mullem, P.J., Vaandrager, J.M., Nicolai, J.P. and de Wijn, J.R. (1990): Implantation of porous acrylic cement in soft tissues: an animal and human biopsy histological study. Biomaterials, 11, 299-304 https://doi.org/10.1016/0142-9612(90)90105-Y
  28. Van, N.R. (1987): Titanium: the implant material of today. J. Mater. Sci., 22, 3801-3811 https://doi.org/10.1007/BF01133326
  29. von Recum, A.F. and van Kooten, T.G. (1995): The influence of micro-topography on cellular response and the implica-tions for silicone implants. J. Biomater. Sci. Polymer Ed., 7,181-198
  30. von Recum, A.E., Opitz, H. and Wu, E. (1993): Collagen type I and III at the implant/tissue interface. J. Biomed. Mater. Res., 27, 757-761 https://doi.org/10.1002/jbm.820270608
  31. Williams, S.K., Berman, S.S. and Kleinert, L.B. (1997): Differ-ential healing and neovascularization of ePTFE implants in subcutaneous versus adipose tissue. J. Biomed. Mater. Res., 35, 473-481 https://doi.org/10.1002/(SICI)1097-4636(19970615)35:4<473::AID-JBM7>3.0.CO;2-E
  32. Wolfaardt, J.F., Cleaton-Jones, P., Lownie, J. and Acker-mann, G. (1992): Biocompatibility testing of a silicone maxillofacial prosthetic elastomer: soft tissue study in primates. J. Prosthet. Dent., 68, 331-338 https://doi.org/10.1016/0022-3913(92)90340-G