A Study on the Emission Characteristics and Prediction of VOCs (Volatile Organic Compounds) using Small Chamber Method

소형챔버법을 이용한 휘발성유기화합물(VOCs) 방출특성 및 예측에 관한 연구

  • Published : 2004.12.30

Abstract

In this study, the measurement system was developed for the measurement of pollutants from building materials, and specimens were made with concrete, gypsum board, mortar and wall paper. Characteristics of VOCs and TVOC concentration and Emission Factor as a function of time were assessed, and the conclusion was drawn as follows. (1) From predicting TVOC concentration decrease of specimen 7 with the wall paper attached to the concrete, the graph may become linear by converting the value of y-axis into the log function, and the prediction equation can be expressed as $y=34906{\ast}e^{-0.0093{\ast}time}$. Moreover, chi-square value was 0.83 which is relatively high value, indicating that TVOC concentration can be properly predicted if the same materials are used indoors. (2) From predicting VOCs Emission Factor decrease of specimen 7, the prediction equation can be expressed as $EF=15111{\ast}e^{-0.0093{\ast}time}$, and chi-square value was 0.83. (3) From predicting TVOC concentration decrease of specimen 7, prediction equation can be considered to be $y=254323{\ast}(1-e^{-0.1046{\ast}time})$, and chi-square was 0.994 which is significantly high value, indicating that indoor TVOC concentration can be properly predicted if the same materials are used indoors. Furthermore, the prediction of concentration decrease using cumulative value of hourly measured concentration is considered to be more accurate than that using just hourly measured value directly. (4) From predicting Emission Factor decrease with cumulative hourly data of Emission Factor, chi-square appeared to be higher than that by just using hourly data of Emission Factor directly. Therefore, the prediction of Emission Factor with cumulative hourly data can provide more reliable prediction equation than the case by using just hourly concentration directly.

Keywords

References

  1. Heward Grafftey 저, 갈원모 외 3인 공역, 안전과 생활, 기문당, 2002
  2. 이민아, 주거 안전 사고의 실태분석, 한양대 석사논문, 1993
  3. 강인호.백혜선, 초고층 아파트 거주자의 건강에 관한 조사연구, 대한주택공사, 2003
  4. 강인호.최병숙, 주거 고층화와 아동의 신체적 병리현상에 대한 실증적 연구, 대한건축학회 논문집, 17권 5호, 대한건축학회, 2001
  5. 손부순.양원호, 실내공기오염, 신광문화사, 2003. 1
  6. 정종훈, 의료보험 체계에서 한국의 질병빈도에 관한 연구, 고려대 대학원 의학과 석사논문, 1992. 12
  7. 한국실내공기.산소연구회, 실내공기와 건강, 신광문화사, 2004. 3
  8. 池田耕一저, 박미진 역, 실내공기오염의 메카니즘, 동화기술, 2004. 1
  9. 유형규.박진철.이언구, 실내건축자재 폼알데히드 및 휘발성유기화합물 방출특성에 관한 연구, 대한건축학회 논문집 21권7호, 대한건축학회, 2005
  10. 안태경, 아파트의 최소필요환기횟수 산정에 관한 연구, 대한건축학회 논문집 21권 12호, 대한건축학회, 2005
  11. George Romney, A design guide for home safety, U.S. dep artment of housing and urban development, Washington, 1972
  12. HMSO, Safety in domestic buildigs, building research stati on digest 43 (2nd series), 1966
  13. E. Maurice backett, Domestc Accidents, Public Health Papers No.26 World Health Organization, Geneva, 1965
  14. 日本建築學會, Strategies to prevent sick house syndrome - design principlesa for healthy life, 2005