DOI QR코드

DOI QR Code

Disinfection of harmful organisms for sea water using electrolytic treatment system

전해처리를 통한 해수의 유해생물 살균처리

  • Park Sang-Ho (Division of Civil and Environmental System Engineering, Korea Maritime University) ;
  • Kim In-Soo (Division of Civil and Environmental System Engineering, Korea Maritime University)
  • 박상호 (한국해양대학교 토목환경시스템공학부) ;
  • 김인수 (한국해양대학교 토목환경시스템공학부)
  • Published : 2004.12.01

Abstract

The treated ballast water from previous treatment contains microorganisms and pathogenic organisms in an electrolytic treatment system. The experimental methods included using a peristaltic flow pump placed upward on an electrode pole. Due to the reaction time, the hydraulic retention time indicated unlike microorganisms on the flow rate. In electrolysis, dioxide iridium-coated titanium (Ti/Ir02) and stainless steel plates were used for the anode and cathode, respectively. Current density controls make use of a DC power supply on 250V, 100Amper. Experimental use of a current density between 0.1 and 1.0A/dm2 was able to disinfect the microorganism (E. coli, Bacteria, Bacillus sp.) in seawater for 5 seconds of reaction time. The removal rate was approximately $90\%,$ while the current density was 2.0A/dm2 and the electrode distance was 75mm. This study shows that the electrolytic treatment system has a potential for the sterilization of ballast water.

선박에서 발생되는 밸러스트수를 전처리하기 위하여 수중에 포함되어 있는 미생물을 복극전해처리시스템을 이용하여 살균처하였다. 전해처리시스템에 유입되는 시료는 정량펌프를 사용하여 상향류로 전극판 사이를 통과하도록 하였으며, 반응시간별로 유량을 조절하여 체류시간을 다르게 하였다. 양극판은 티타늄에 이산화이리듐을 전착한 Ti/Ir02 극판으로 하였으며, 음극판은 스테인리스 스틸판을 사용하였다. 전원공급은 최대 전압이 250V, 전류가 100Amper의 맥류가 전혀 없는 트랜지스트 평활회로를 사용한 D.C. Power Supply를 사용하여 전류밀도를 조절하여 운전하였다. 반응시간에 따라 전류밀도를 0.1$\~$1.0A사이로 변화를 주어 실험한 결과 5초 이내에 E. coli, Bacteria, Bacillus sp.의 미생물이 사멸됨을 확인할 수 있었고, 전극간격은 75mm, 전류밀도 2.0A/dm2, 체류시간을 5초로 하였을 때 제거율이 $90\%$이상이였다. 연구결과를 통하여 밸러스트수 처리에 적용 가능한 기술임을 알 수 있었다.

Keywords

References

  1. 길대수, 이병헌, 이제근 (2000) 전기분해에 의한 고농도 유기물질 제거 특성, 대한환경공학회지, Vol. 22, No. 2, pp.251-264
  2. 김인수 (1994) DSA 전극에 의한 선박오폐수의 전해처리(I), 회분식 전해처리, 해양안전학회지, Vol. 3, No. 2, pp.69-76
  3. 정진웅, 김종훈, 김병삼, 정승원 (2003) 전기분해 격막 및 전해액에 따른 전해수의 특성 비교, 한국식품저장유통학회지, Vol. 10, No. 1, pp.99-105
  4. Albrich, J.M., Gilbaugh III, J.H., Callahan, K.B., Hurst, J.K. (1986) Effects of the putative neutrophil-generated toxin, hypochlorous acid, on membrane permeability and transport systems of Escherichia coli. J. Clin Invest. 78, pp.177-184 https://doi.org/10.1172/JCI112548
  5. Barrette Jr.,W.C., Hannum, D.M., Wheeler, W.D., Hurst, J.K. (1989) General mechanism for the bacterial toxicity of hypochlorous acid: abolition of ATP production. Biochemistry 28, pp.9172-9178 https://doi.org/10.1021/bi00449a032
  6. Cenkin. V. E. and Belevtsev. A. N. (1985) Electrochemical treatment of industrial wastewater, Effluent and Water Treatment Journal, 25, pp.243-247
  7. Christopher M. and Richard L. (1995) Oxidation behavior of aqueous contaminants in the presence of hydrogen peroxide and filter media. J. Hazardous Mater. 41, 105.116 https://doi.org/10.1016/0304-3894(94)00098-2
  8. Chyer Kim, Yen-Con Hung , Robert E. Brackett. (2000) Efficacy of electrolyzed oxidizing (EO) and chemically modified water on different types of foodborne pathogens
  9. Costaz. P., Miquel. J. and Reinbold (1983) Si-multaneous electroflotation and disinfection of sewage, Water Research, Vol. 17, No. 3, pp.255-262 https://doi.org/10.1016/0043-1354(83)90178-1
  10. Hayes, K.R, Sliwa, C., (2003) Identifying potential marine pests a deductive approach applied to Australia. Mar. Pollut. Bull. 46, pp.91-98 https://doi.org/10.1016/S0025-326X(02)00321-1
  11. Hurst, J.K., Barrette Jr., W.C., Michel, B.R., Rosen, H., (1991) Hypochlorous acid and myeloperoxidase-catalyzed oxidation of iron-sulfur clusters in bacterial respiratory dehydrogenase. Eur. J. Biochem. 202, pp.1275-1282 https://doi.org/10.1111/j.1432-1033.1991.tb16500.x
  12. International Maritime Organisation (IMO), (2003) Marine Environmental Protection Committee (MEPC), Draft International convention for the control of management of ships' ballast water and sediments. MEPC 49/2/3, 24 March
  13. Jolley R., Cumming R., Lee N. and Lewis L. (1982) Micropollutants produced by disinfection of wastewater e.uents. Water Sci. Techol. 14, pp45.59
  14. Leyer, G.J., Johnson, E.A., (1997) Acid adaptation sensitizes Salmonella typhimuhum to hypochlorous acid. Appl. Environ. Microbiol. 63, pp.461-467
  15. P. Drogui, s. Elmaleh, m. Rumeau, c. Bemard and a. Rambaud (2001) Oxidising and Disinfecting by Hydrogen Peroxide Produced in a two-electrode cell Wat. Res. Vol. 35, No. 13, pp.3235.3241
  16. Scarpino, P.V., G.Berg,S.L. Chand, D.Dhling and M.Lucas (1972) Bacterial air pollution from sewage treatment plants Water. Res. Vol. 26, pp.959