DOI QR코드

DOI QR Code

Telemetry capsule for pressure monitoring in the gastrointestinal tract

소화관 내 압력 측정을 위한 텔레메트리 캡슐 구현

  • Yoon, Ki-Won (School of Electrical Engineering and Computer Science, Kyungpook National Univ.) ;
  • Woo, Sang-Hyo (School of Electrical Engineering and Computer Science, Kyungpook National Univ.) ;
  • Lee, Jyung-Hyun (School of Electrical Engineering and Computer Science, Kyungpook National Univ.) ;
  • Moon, Yeon-Kwan (School of Electrical Engineering and Computer Science, Kyungpook National Univ.) ;
  • Park, Hee-Joon (School of Electrical Engineering and Computer Science, Kyungpook National Univ.) ;
  • Won, Chul-Ho (Department of Control and Instrumentation Engineering, Kyungil University) ;
  • Kim, Byung-Kyu (Korea Institute of Science and Technology (KIST)) ;
  • Choi, Hyun-Chul (School of Electrical Engineering and Computer Science, Kyungpook National Univ.) ;
  • Cho, Jin-Ho (School of Electrical Engineering and Computer Science, Kyungpook National Univ.)
  • 윤기원 (경북대학교 전자전기컴퓨터학부) ;
  • 우상효 (경북대학교 전자전기컴퓨터학부) ;
  • 이정현 (경북대학교 전자전기컴퓨터학부) ;
  • 문연관 (경북대학교 전자전기컴퓨터학부) ;
  • 박희준 (경북대학교 전자전기컴퓨터학부) ;
  • 원철호 (경일대학교 제어계측공학과) ;
  • 김병규 (한국과학기술연구원) ;
  • 최현철 (경북대학교 전자전기컴퓨터학부) ;
  • 조진호 (경북대학교 전자전기컴퓨터학부)
  • Published : 2005.07.30

Abstract

As the cause and the treatment about gastrointestinal disease has been issued recently, the importance of measuring the pressure in the gastrointestinal tract has been increased. However, the conventional measurement methods of the pressure in the gastrointestinal tract cause the patients' pain and inconvenience as well as an inaccurate pressure measurement. In this paper, the pressure monitoring telemetry system has been designed and implemented for an accurate pressure measurement inside the gastrointestinal tract with minimizing pain and inconvenience. The pressure monitoring telemetry system is composed of a pressure measurement capsule and an external receiver. The capsule has been miniaturized into the same size of a vitamin tablet so that the capsule can be swallowed through the oral cavity. After the capsule acquires and encodes the pressure data in the gastrointestinal tract, the encoded pressure data are modulated by frequency shift keying (FSK) and transmitted with ultrahigh frequency (UHF) band signal to the outside of a body. The performance of the telemetry capsule for monitoring pressure in the gastrointestinal tract is demonstrated by the results of animal in-vivo experiments.

Keywords

References

  1. A. Sonnenberg, Esophageal diseases Digestive Diseases in the United States: Epidemiology and Impact, National Institutes of Health publication 941447. Washington, D.C., 1994
  2. D. Brown and J. Everhart, Cost of digestive care in the United States Digestive Diseases in the United States: Epidemiology and Impact, National Institutes of Health publ ication 94-1447, Washington, D.C., 1994
  3. M. Jain, Q. Cai, and C. Grimes, 'A wirele ss microsensor for simultaneous measurement of pH, temperature, and pre ssure', Institute of Physics - Smart Materials and Structures, vol. 10, pp. 347-353, 2001 https://doi.org/10.1088/0964-1726/10/2/322
  4. H. J. Park, H. W. Nam, B. S. Song, J. L. Choi, H. C. Choi, J. C. Park, M. N. Kim, and J. H. Cho, 'De sign of Bi-directional and multi-channel miniaturized telemetry module for wireless endo scopy', International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine & Biology, pp. 273-276, 2002
  5. http://www.gastro .org/clinicaIRes/brochures/hemorrhoids. html, American Gastroenterological Association , U.S.A.
  6. P. Kahrilas, S. Lin, J. Chen , and M. Manka, 'The effect of hiatus hernia on gastro-oesophageal junction pressure', Gut, vol. 44, pp. 476-482, 1999 https://doi.org/10.1136/gut.44.4.476
  7. H. Skinner, N. Bedforth, K. Girlin g, and R. Mahajan, 'Effect of cricoid pressure on gastrooesophageal reflux in awake subjects', Anaesthesia, vol. 54, pp. 798-800, 1999 https://doi.org/10.1046/j.1365-2044.1999.00906.x
  8. F. Gudmundsson, H. Gislason, A. Dicko, A. Hom, A. Viste, K. Grong, and K. Svanes, 'Effects of prolonged increased intra-abdominal pressure on gastrointestinal blood flow in pigs', Surgical Endoscopy - Ultrasound and Interventional Techniques, vol. 15, pp. 854-860, 2001 https://doi.org/10.1007/s004640090090
  9. http://www.adinstruments.com/research/rapps/gasstud. html, ADlnstruments, U.S.A
  10. R. S. Mackay, 'Bio-medical telemetry : sensing and transmitting biological information from animals and man', IEEE press, 2nd ed., New York, 1993
  11. G Bistue, J. Elizalde, I. Garci a-Alonso, S. Olaizola, E. Castano, F. Gracia, and A. Garcia-Alonso, 'A micromachined pressure sensor for biomedical applications', Journal of Micromechanics and Microengineering, vol. 7, pp. 244-246, 1997 https://doi.org/10.1088/0960-1317/7/3/044
  12. 장경만, 문연관, 류원열, 윤영섭, 조진호, 최현철, '초소형 무선 내시경용 FSK 송신기 설계 및 제작', 한국전자파학회지, 제14권, 제9호, pp. 936-943, 2003
  13. 박종철, 박희준, 이정우, 송병섭, 이승하, 조진호, '체외 제어 가능한 소화관 자극용 초소형 캡슐 구현', 센서학회지, 제12권, 제4호, pp. 175-184, 2003
  14. 박종철, 남혜원, 박희준, 송병섭, 원철호, 이승하, 최현철, 조진호, '비선형 연립방정식에 의한 체내 삽입형 초소형 텔레메트리 모듈의 3차원 위치 추적 방법', 센서학회지, 제12권, 제6호 pp. 249-257, 2003