A Study on Improvement of Shear Test Apparatus in the Direct Shear Test Under Constant Pressure

정압(CD)조건 직접전단시험에 있어서 시험기의 개선에 관한 연구

  • Published : 2005.03.01

Abstract

A direct shear test is classified roughly by one side simple shear test of confining horizontal displacement type and torsional shear test of non-confining one. Direct shear test that has been widely used so far has some problems with test apparatus, testing and the analysis, and in particular that its strength value is everestimated in sandy soils. Also, progressive failure of shearing process happens from shear apparatus restriction and because the shear strain and shear stress are erratic in specimen, we can not define the shear strain value. In the meantime, a simple shear test having advantage of direct shear test is an ideal test method that can get stress-strain relation on shear because it can deliver constant shearing deformation to specimen. However, simple shear test cannot be used practically, because its structure makes tester manufacturing difficult. This paper described a on outline of test apparatus, improvement of test method, and constant pressure test results based on the obtained from improved direct shear apparatus and the standardization of JGS soil testing method.

직접전단시험은 측방변위 구속형의 일면·단순전단시험과 측방변위 비구속형의 비들림 전단시험으로 대별된다. 현재까지도 가장 많이 사용되고 있는 직접전단시험은 시험기 및 시험방법과 결과의 해석 등에 몇 가지의 문제점이 있었으며, 특히 사질토에서는 강도가 과대하게 평가되는 등의 지적이 있었다. 또한 시험기구상의 제약으로부터 전단과정 중 진행성 파괴를 일으키는 점, 공시체내의 전단변형량과 전단응력이 일정하지 않기 때문에 전단변형량을 정의할 수 없는 점 등이 있다. 한편 단순전단시험은 직접전단시험의 장점을 그대로 가지면서, 공시체에 일정한 전단변형을 전달할 수 있기 때문에 전단에 대한 응력-변형량 관계를 얻을 수 있는 이상적인 시험법이라고 할 수 있다. 그러나 단순전단시험은 그 구조상, 시험기제작이 어려운 점 등 아직도 실용적인 시험기의 완성에는 도달하지 못하고 있는 실정이다. 본 논문에서는 간이 전단시험방법 및 시험기의 문제점을 개선한 개량형 일면전단 시험기의 제작과 일본 지반공학회 토질시험법의 기준화과정에서 얻은 시험결과를 바탕으로 시험기의 개요와 시험법의 개선, 정압조건의 시험결과에 대해 서술하였다.

Keywords

References

  1. Kim J., So C., Ohshima A., and Takada N. (2004), 'A study on shear test of the condition of consolidated constant pressure with improvement one-dimension shear test and strength properties', Proc. of annual convention of KSCE, Fall Conference, pp.1434-1438. (in Korean)
  2. Mikasa M. (1960), New One-Dimension Shear Testing Structure, Proc. of annual convention of JSCE, pp.45-48. (in Japanese)
  3. Takada N., Ohshima A., and Sakamoto K. (1996), 'Comparison of simplified shear test and a true one-dimensional shear test of constant pressure', Proc. of annual convention of JGS, pp.665-666. (in Japanese)
  4. New Standards and Commentary by Japanese Geotechnical Society IV (1997), One side Shear Test Method of Soils, Japanese Geotechnical Society (in Japanese)
  5. Methods and Commentary of Soil Testing (2000), Japanese Geotechnical Society, pp.563-574. (in Japanese)
  6. Soil Test (2000), Japanese Geotechnical Society, pp.121-134. (in Japanese)
  7. Ohshima A. and Morimoto K. (2002), 'Comparison of strength character one-dimension shear test with condition of consolidated constant pressure of sand', Proc. of annual convention of JSCE, III-295, pp.589-590. (in Japanese)
  8. Yang T, Kim J, and Koh Y. (2004), 'An application of soil properties in port Construction Project', Proc. of annual convention of KSCE, Fall Conference, Special Committee, pp.1434-1438. (in Korean)