Cost Accounting of Heat and Electricity of a Combined Cycle Cogeneration System

복합열병합 시스템에 대한 열과 전기의 원가산정

  • Published : 2005.06.01

Abstract

The cost accounting of electricity and heat produced from an energy system is important in evaluating the economical efficiency and deciding the reasonable sale price. The OECOPC method, suggested by the author, was applied to a 650 MW combined cycle cogeneration system having 4 operating modes, and each unit cost of electricity and heat products was calculated. In case that a fuel cost is ${\\}400/kg$ and there are no direct and indirect cost, they were calculated as follows; electricity cost of ${\\}23,700/GJ$ at gas-turbine mode, electricity cost of ${\\}15,890/GJ$ at combined cycle mode, electricity cost of ${\\}14,146/GJ$ and heat cost of ${\\}6,466/GJ$ at cogeneration mode, and electricity cost of ${\\}14,387/GJ$ and heat cost of ${\\}4,421/GJ$ at combined cycle cogeneration mode. Further, these unit costs are applied to account benefit on this system. Since the suggested OECOPC method can be applied to any energy system, it is expected to contribute to cost accounting of various energy systems.

Keywords

References

  1. Lozano, M. A. and Valero, A., 1993a, Theory of the exergetic cost, Energy, Vol. 18, pp. 939-960 https://doi.org/10.1016/0360-5442(93)90006-Y
  2. Lozano, M. A. and Valero, A., 1993b, Exergoeconomic analysis of gas-turbine cogeneration systems, Proceedings of the ASME Advanced Energy Systems Division, AES-Vol. 30, pp. 311-320
  3. Valero, A., Lozano, M. A., Serra, L., Tsatsaronis, G., Pisa, J., Frangopoulos, C. A. and von Spakovsky, M. R., 1994, CGAM problem: Definition and conventional solution, Energy, Vol. 19, No. 3, pp. 279-286 https://doi.org/10.1016/0360-5442(94)90112-0
  4. Lazzaretto, A. and Tsatsaronis, G., 1996, A general process-based methology for exergy costing, in Duncan, A. B., Fiszdon, J., O'Neal, D. and Den Braven, K.(eds.), Proceedings of the ASME Advanced Energy Systems Division, AES-Vol. 36, ASME, New York, pp. 413-428
  5. Oh, S. D., Pang, H. S., Kim, S. M. and Kwak, H. Y., 1996, Exergy analysis for a gas turbine cogeneration system, Journal of Engineering for Gas Turbine and Power, Vol. 118, pp. 781-791
  6. Kim, D. J., Jeon, J. S. and Kwak, H. Y., 1999, Exergetic and thermoeconomic analysis of combined cycle plant, Proceeding of the ASME Advanced Energy Systems Division, AES-Vol. 39, pp. 397-405
  7. Kwak, H. Y., Kim, D. J. and Jeon, J. S., 2003, Exergetic and thermoeconomic analyses of power plants, Energy, Vol. 28, pp. 343-360 https://doi.org/10.1016/S0360-5442(02)00138-X
  8. Kim, D. J., 2003, Suggestion of power and heat costing for a energy system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 15, No. 5, pp. 360-371
  9. JANAF Thermochemical Tables, 1971, National Bureau of Standards Publications, Washington, DC
  10. JSME Steam Tables, 1968, Japanese Society of Mechanical Engineers