DOI QR코드

DOI QR Code

The Vibration Velocity and Vibration Level of Near-field Blasting Vibration in an Urban Blasting Site

근접장 발파진동에서 진동속도와 진동레벨의 비교

  • 이연수 (서울시보건환경연구원) ;
  • 장서일 (서울시립대학교 환경공학부)
  • Published : 2005.08.01

Abstract

The vibration level (dB(V)) and vibration velocity (cm/sec) on the ground and buildings due to the differences of the measuring sites from the blasting source was investigated. To compare with vibration level and vibration velocity theirs magnitude was not surely directly proportional and vibration velocity 0.1 cm/sec was $45\~50$ dB(V). The difference between the measured vibration level and the calculated vibration level by Ejima's equation using vibration velocity PVS(peak vector sum) showed $21.0\~30.9$ dB(V) on the ground, $15.3\~23.6$ dB(V) on the apartment, respectively. And the correlation of vibration velocity and nitration level at the measuring sites of lower altitude showed higher than that of higher altitude.

Keywords

References

  1. 류창하, 선우춘 외, 1994, '안전관련 구조물 근접 공사시 발파진동 허용기준의 적용성에 관하여 ', 한국암반역학회, 제 4 권, pp. 287 -297
  2. 우재윤, 1995, '우리나라 지반진동 허용기준의 제정 및 적용에 관한 제안( I)', 한국지반공학회, pp. 117-141
  3. (社)日本騒音制御工學會技術部會編. 1996.發破による音と振動,山海堂,東京. pp. 72-75
  4. 김남수, 양형식, 2000, '발파소음의 예측기법과 환경규제기준으로의 변환연구', 화약발파, 제 18권 제 2 호, 한국화약기술협회, pp 14:-22
  5. 김재영, 홍응기 외, 2001, '주민생활환경에 있어서 진동레벨에 의한 발파진동의 평가', 대한환경공학회 2001 춘계학술연구발표회 논문집(II), pp.141-144
  6. 이연수, 장서일, 2004, '도심지 발파공사장의 발파진동 특성', 한국소음진동공학회논문집, 제 14권, 제 7 호, pp. 632 -638