An Experimental Study on the Application of Polypropylene Capillary Tube Cooling System

폴리프로필렌 모세유관 냉방시스템의 적용에 관한 실험적 연구

  • 이영주 (서울대학교 건축학과 대학원) ;
  • 김오봉 (서울대학교 건축학과 대학원) ;
  • 김광우 (서울대학교 건축학과) ;
  • 여명석 (서울대학교 건축학과)
  • Published : 2005.09.01

Abstract

In this study, we made RFC, RCC and NCC according to the method by which polypropylene capillary tube was adopted, and evaluated cooling performance of each system through model experiments. We also investigated an applicability of the combined use of radiant cooling and dehumidification system. The results are as follows: In case of normal cooling load, RFC and RCC maintained set temperature without a condensation. But, in case of peak cooling load, RFC and RCC resulted in the lack of cooling performance and caused a condensation at the radiation surface. Consequently, the only use of polypropylene capillary tube is considered not to be enough for cooling in real application. Using the combination of a dehumidification and radiant cooling system maintained the set temperature without a condensation. NCC kept the set temperature at anytime without a condensation. It is more economic than packaged air-conditioner system due to the cooling effect of the floor surface.

Keywords

References

  1. Koo, S. Y., Kim, Y. Y., Seok, H. T., Lee, H. W. and Kim, K. W., 2000, A study on the applicability of radiant cooling using Ondol, Korea Journal of Air-conditioning and Refrigeration Engineering, Vol. 12, No.2, pp. 200-208
  2. Kim, Y. Y, Yoon, H. L. and Yeo, M. S., 2001, A study on the control of water flow and temperature in the radiant cooling system through simulations, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 13, No.6, pp. 532-540
  3. Lee. S. Y, Hwang, S. H., Kim, K. H. and Leigh, S. B., 2002, An experimental study for evaluation performance of radiant floor cooling system integrated with dehumidification, Korean Journal of Air-conditioning and Refrigeration Engineering, Vol. 14, No.2. pp. 142-152
  4. Kim, Y. Y., Lim, J. H., Yeo, M. S. and Kim, K. W., 2001, An experimental study on control performance of radiant floor cooling using Ondol, Korean Journal of Air-conditioning and Refrigeration Engineering, Vol. 13, No. 11, pp. 1165-1173
  5. Song, G. S., Jeon, B. K., Kim, K. H. and Jeon, S. W., 2001, A study on the comfort comparison based on thermal characteristics of the floor materials-steel, urethane rubber, pine tree, clay at the seating life style, Journal of the Architectural Institute of Korea, Vol. 17, No.2, pp.207-216