This study was carried out to develop enzyme biosensor for lactic acid bacteria. Lactic acids produced by lactic acid bacteria (LAB) was measured and good correlation $R^2=0.98$ between LAB count and lactic acids concentration was found. Hydrogen ion produced by L-lactate dehydrogenase (L-LDH) was measured by a potentiometer. Glutamic-pyruvic transminase (GPT) was used for eliminating inhibitor in the reaction. Polyacrylamide gel was used for immobilizing matrix of the sensor. The biosensor was tested and showed good feasibility with $R^2=0.99$ on validation.

Keywords

References

  1. Casimiri, W. and C. Burstein. 1996. Co-immobilized L-lactate oxidase and L-lactate dehydrogenase on a film mounted on oxygen electrode for highly sensitive L-lactate determination. Biosensors & Bioelectronics. 11(8):783-789 https://doi.org/10.1016/0956-5663(96)85929-X
  2. Clark, Jr. L. C. and C. Lyons. 1962. Electrode systems for continuous monitoring in cardiovascular surgery. Ann. N.Y. Acad. Sci. 102:29 https://doi.org/10.1111/j.1749-6632.1962.tb13623.x
  3. Eggins, B. R. 2002. Chemical sensors and biosensors. John Wiley & Sons Ltd. England
  4. Kim, J. H., D. H. Rhie, T. J. Kim and B. S. Noh. 1998. Development of Biosensor for Simultaneous Determination of Glucose, Lactic Acid and Ethanol. Korean J. Food Sci. Technol. 30(1):22-34. (In Korean)
  5. Ko, Y. D., H. Y. Chung, K. S. Kim, K. H. Lee, Y. W. Kim, S. S. Chun and N. K. Sung. 1994. Effect on Fermentation and Storage of Yogurt Using Control System of Refrigerator. Korean J. Food Sci. Technol. 26(6):814-818. (In Korean)
  6. Mizutani, F., S. Yabuki and Y. Hirata. 1995. Amperometric L-lactate-sensing electrode based on a polyion complex layer containing lactate oxidase. Application to serum and milk samples. Analytica Chimica Acta. 314:233-239 https://doi.org/10.1016/0003-2670(95)00278-8
  7. Mizutani, F., S. Yabuki and Y. Hirata. 1996. Flow injection analysis of L-lactic acid using an enzyme-polyion complex-coated electrode as the detector. Talanta. 43:1815-1820 https://doi.org/10.1016/0039-9140(96)01952-2
  8. Sivakesava, S., J. Irudayaraj and D. Ali. 2001. Simultaneous deter mination of multiple components in lactic acid fermentation using FT-MIR, NIR, and FT-Raman spectroscopic techniques. Process Biochemistry. 37:371-378 https://doi.org/10.1016/S0032-9592(01)00223-0
  9. Yoon, H. C. 1995. Thick-film amperometric L-Lactate biosensor using L-lactate dehydrogenase. M.S. thesis. Korea Advanced Institute of Science and Technology
  10. Zhang, J., Y. Xie, X. Dai and W. Wei. 2001. Monitoring of Lactobacillus fermentation process by using ion chromatography with a series piezoelectric quartz crystal detector. J. Microbiological Methods. 44:105-111 https://doi.org/10.1016/S0167-7012(00)00238-4
  11. 김민곤. 2002. 바이오센서 기술동향. 한국생명공학연구원 보건산업기술동향. 25-33
  12. 김현욱. 1988. 낙농 및 식품 미생물학 실험. 유한문화사
  13. 백영진. 1997. 국내 드링크 요구르트의 종류와 특성. 우유. 1997(71):15-19