Simultaneous detection method for pesticide residues in meat by gas chromatograph-mass selective detector

Gas chromatograph-mass selective detector를 이용한 식육 중 잔류농약의 동시분석

  • Hong In-Suk (Seoul Metropolitan Health & Environment Research Institute) ;
  • Choi Yoon-Hwa (Seoul Metropolitan Health & Environment Research Institute) ;
  • Kweon Taek-Boo (Seoul Metropolitan Health & Environment Research Institute) ;
  • Lee Jung-Hark (Seoul Metropolitan Health & Environment Research Institute)
  • 홍인석 (서울특별시 보건환경연구원) ;
  • 최윤화 (서울특별시 보건환경연구원) ;
  • 권택부 (서울특별시 보건환경연구원) ;
  • 이정학 (서울특별시 보건환경연구원)
  • Published : 2005.09.01

Abstract

This study was conducted to investigate the extraction method for the determination of organochlorine, organophosphorus and synthetic pyrethroid pesticide residues in beef fat by gas chromatography-mass selective detector(GC-MSD). Twenty one pesticide residues in fat were determined using a simple and rapid procedure based on solid- phase extraction(SPE) clean-up cartridges with octadecyl $(C_{18})-bonded$ porous silica, florisil, $10\%$ deactivated florisil. a tandem $C_{18}$ and florisil and a tandem $C_{18}$ and $10\%$ deactivated florisil. Solvent-solvent extraction using acetonitrile was not satisfied to eliminate fat interference for pesticide residue analysis by GC-MSD, and the recoveries of the method in fat ranged from 16.2 to $57.3\%$ except DDT$(83.2\%)$. The recoveries of SPE methods using a tandem $C_{18}$ and Florisil was $59.6\~123.8\%$ except fenitrothion $(135.2\%)$. the SPE method was verified the satisfactory performance of pre-treatment for pesticide residues analysis in fat by GC-MSD. The efficiency of florisil deactivated with $10\%$ water has been not proved significantly on recoveries of pesticide residues in fat.

Keywords

References

  1. 박준조, 김정임, 김재관 등. 1996. 식육중 잔류농약추출방법과 잔류량에 관한 연구. 수의공중보건학회지 20(3):231-240
  2. 식품의약품안전청, 2004. 식품공전 : 954-961
  3. 농림부. 2003. 식육중잔류물질검사요령 및 식육중미생물검사요령; 농림부고시 제 2003-27호:5-15
  4. Vazquez ml, Langure A, Orantes C, et al. 1999. Incidence of pesticide residues in adipose tissue of beef, pork and poultry from plants located in Northwestern Mexico. J Muscle Foods 10(4):295-303 https://doi.org/10.1111/j.1745-4573.1999.tb00404.x
  5. Argauer RJ, Lehotay SJ, Brown RT. 1997. Determining lipophilic pyrethroids and chlorinated hydrocarbons in fortified ground beef using ion-trap mass spectrometry. J Agri Food Chem 45(10):3936-3939 https://doi.org/10.1021/jf9701953
  6. Sun F, Lin FY, Wong S. 2003. The screening of organophosphorus, organochlorine and synthetic pyrethroid pesticides residues in beef fat by tandem solid-phase extraction technique. J Food Dr${\mu}g$ Anal 11(3):258-265
  7. Kuivinen J, Bengtsson S. 2002. Solid- phase extraction and cleanup of organophosphorus pesticide residues in bovine muscle with gas chromatographic detection. J Chromatographic Sci 40(7):392-396 https://doi.org/10.1093/chromsci/40.7.392
  8. Doong RA, Lee CY. 1999. Determination of organochlorine pesticide residues in foods using solid-phase extraction clean- up cartridges. Analyst 124(9):1287-1289 https://doi.org/10.1039/a902722j
  9. Schenck FJ, Calderon L, Podhorniak LV. 1996. Determination of organochlorine pesticide and polychlorinated biphenyl residues in fatty fish by tandem solid-phase extraction cleanup. J AOAC Int 79(5):1209-1214
  10. Gillespie AM, Walters SM. 1991. Rapid clean-up of fat extracts for organophosphorus pesticide residue determination using C*d1*d8 solid-phase extraction cartridges. Anal Chimica Acta 245(2):259-265 https://doi.org/10.1016/S0003-2670(00)80230-5
  11. Armishaw P, Millar RG. 1993. Comparison of gel permeation chromatography, sweep codistillation, and Florisil column adsorption chromatography as sample cleanup techniques for the determination of organochlorine pesticide residues. J AOAC Int 76(6):1317-1322