Evaluation of Static Strength of Mixed Stud Shear Connection in Double Composite Bridges

이중합성 교량의 복합스터드 전단연결부의 정적강도 평가

  • Received : 2005.05.30
  • Accepted : 2005.09.05
  • Published : 2005.10.27

Abstract

A railway bridge with a double composite section is proposed to enhance the structural performance of existing two-girder bridges because the governing design parameter of railway bridges is the flexural stiffness. The concrete deck in negative moment regions is neglected in the design of continuous composite bridges assuming the concrete slab has no resistance to tension. Therefore, the flexural stiffness of the composite section in the negative moment region is reduced resulting in the increase of the depth of the steel section. In order to resolve this disadvantage, several methods are suggested and the double composite section is one of the excellent solutions for extending the span length and increasing the flexural stiffness. In this study, push-out tests on lying studs and mixed stud shear connection with lying and vertical studs were performed to investigate the behavior of the shear connection in the double composite section. Static strength of the shear connection was evaluated through the test results and numerical analyses.

철도교는 강성이 주요한 설계인자이기 때문에 기존의 2거더 교량의 구조적 효율성을 높이기 위해서 이중합성 구조를 가진 철도교를 제안하였다. 일반적으로 강합성 연속교를 설계할 경우, 부모멘트 구간에 존재하는 콘크리트 바닥판은 인장에 저항하지 못한다고 가정하고 바닥판 단면을 무시하게 된다. 부모멘트 구간에서는 합성단면의 강성이 감소하게 되므로 이를 보완하기 위해 강재단면이 커지게 되는데, 이러할 경우 변단면의 적용이 불가피하게 되고 강합성형으로서의 장점이 반감된다고 할 수 있다. 이와 같은 문제점을 해결하기 위한 다양한 접근법이 존재하지만 그 중에서도 경간을 확대하고 강성이 중요한 설계인자가 되는 경우에 적절하게 사용될 수 있도록 제안된 교량의 형태가 이중합성구조이다. 따라서 본 연구에서는 이중합성 전단연결부의 거동을 파악하기 위하여 수평스터드, 수평스터드와 수직스터드가 함께 배치된 복합스터드 부재에 대한 push-out 실험을 수행하였다. 실험결과의 분석을 통하여 기존의 설계식과의 비교를 수행하고 정적 거동을 평가하였다.

Keywords

References

  1. 김현호, 심창수, 윤광중, 이필구 (2004), 이중합성 구조를 갖는 강합성고속철도교의 설계에 관한 연구, 대한토목 학회 학술발표회 논문집, pp. 4624-4627
  2. 도로교설계기준, 도로교통협회, 2005
  3. AASHTO LRFD Bridge Design Specifications, Third Edition, 2004
  4. Breuninger & Kuhlmann (2000) : Behaviour of Lying Studs with Longitudinal Shear Force, Engineering Foundation Conference, ASCE, Composite Construction in Steel and Concrete IV, Banff
  5. Eurocode 4 (1994), Design of composite Steel and Concrete Structures, Part 1-1 : General rules and rules for buildings, ENV 1994-1-1
  6. Eurocode 4 (2002), Design of composite steel and concrete structures, Part 2: Composite bridges (ENV 1994-2), CEN
  7. Francisco, Millanes (2004), The Spanish Experience in Double Composite Bridges: evolution and application to some exceptional bridges, Steel Bridge 2004, pp. 1-15
  8. Kai Kurschner (2003), Trag-und Ermudungsverhalten liegender kopfbolzendubel im Verbundbau, Institut fur Konstruktion und Entwurf der Universitat Stuttgart
  9. Kuhlmann, U.; Kurschner, K.(2001), Design of Lying Studs with Longitudinal Shear Force, Symposium on Connections between Steel and Concrete, 55th Rliem Annual Week in Stuttgart, Germany
  10. Kuhlmann, U.; Kurschner, K.(2001), Behaviour of Lying Shear Studs in Reinforced Concrete Slabs, Symposium on Connections between Steel and Concrete, 55th Rliem Annual Week in Stuttgart, Germany
  11. Oehlers, D.J, Bradford, M.A (1995), Composite steel and concrete structural members, PERGAMON
  12. Saul, R. (1996) Bridges with Double Composite Action, Journal of the IABSE, Structural Engineering International, Vol. 6, pp. 32-36
  13. 大山 里, 栗田 章光. (2000) 鋼․コンクリ一ト二重合成連 續箱桁僑の乾燥收縮擧動關する解析および實驗的硏究, 日本鋼構造論文集, 第7卷 第27號, pp. 71-84