An Analysis of the Internal Deformation Behaviors of Geosynthetic Reinforced Soil Walls used Clayey Soil as Backfills

뒤채움재로 점성토를 사용한 보강토벽의 내적 거동 분석

  • 김흥기 (호원대학교 공과대학 건축토목공학부) ;
  • 김유성 (전북대학교 공과대학 토목환경공학부)
  • Received : 2005.02.22
  • Published : 2005.06.01

Abstract

In this study, the fifteen month behavior of two geosynthetic reinforced walls which was constructed on the shallow weak ground was measured and analyzed. The walls were backfilled with clayey soil obtained from the construction site nearby, and the safety factors obtained from general limit equilibrium analysis were less than 1.3 in both wall. The measured and analyzed data were horizontal earth pressures, strain of reinforcements, and excess pore water pressures. The used reinforcements were nonwoven geotextile, woven geotextile and geogrid. Although the length of reinforcement was only 30% of wall height and the safety factors of the walls were less than 1.3, the walls were constructed without any problems on the such weak ground. The analysis results showed that the maximum strain of reinforcements were negligible and the strain was between 2.3 and 6.0% according to tensile characteristic of the reinforcements. The excess pore water pressure was not changed due to the rainfall and the horizontal earth pressures in upper and lower part of the walls were larger than the active and the rest pressure.

보강토벽의 안정성을 증명하고, 경제성의 극대화를 도모하기 위해, 본 연구에서는 뒤채움재로 현지 점성토를 사용하고 보강재로 부직포와 직포 그리고 부직포와 지오그리드를 혼합 배치하여 일반적인 한계평형해석으로는 안전율이 1.3미만인 2개의 실물 보강토벽을 얕은 연약지반 상에 구축하여 보강재, 수평토압, 그리고 간극수압 등의 거동을 약 15개월 동안 계측 및 분석하였다. 보강재의 길이를 보강토벽 높이의 30%로 설계하였고, 그에 따라 일반적인 한계평형해석에 의한 보강토벽의 안전율이 1.3미만 임에도 불구하고 2개의 실물보강토벽이 얕은 연약지반 상에 안전하게 구축되었고, 분석결과 보강재의 최대변형은 보강재의 특성에 따라 2.3~6.0%로 안전하고, 간극수압은 강우의 영향을 거의 받지 않는 것으로 나타났으나 수평토압은 안전율과 부등침하 등의 영향으로 보강토벽의 상 하부에서 주동토압과 정지토압보다 큰 것으로 나타났다.

Keywords