Abstract

In this study, the PSC girder bridge retrofitted with external tendons is tested to verify the strengthening effects. We measure the variations of the displacement and strain at mid-span of each beam as external tendons are removed in sequence. The structural behavior of the bridge are examined using controlled truck load tests for the systems before and after all external tendons were removed. From the test results, the characteristics of structural behavior of the bridge do not change significantly, but the natural frequency is decreased after the external tendons are removed. The strengthening effects of bridges can be exactly estimated by analytical methods some extent. As a result of this study, when a PSC girder bridge is deteriorated, the bridge can be retrofitted effectively by External Prestressing Strengthening Method, and the strengthening effects can be predicted through accurate structural analysis.

본 연구에서는 장기공용 중 외부강선보강공법에 의하여 보강된 PSC Beam교량에 대한 강선 파단 시험을 통하여 보강효과를 분석하였다. 외부강선 보강효과를 분석하기 위하여 기 보강된 강선을 인위적으로 절단하면서, 교량의 처짐과 변형률을 측정하였다. 또한 강선절단 전과 후에 재하시험을 실시하여 교량의 거동변화를 평가하였다. 실험결과에 의하면 외부강선 절단 전과 후의 재하시험을 통하여 보강효과가 교량의 거동특성을 크게 변화시키지는 않지만, 보강시의 긴장력에 의하여 고유진동수는 증가하였다. 외부강선 절단시의 처짐과 응력 계측결과로부터 보강효과가 충분히 유지되고 있다는 것을 확인할 수 있었으며, 구조해석 결과와도 잘 일치하였다. 따라서 외부강선을 이용하여 노후교량을 보강할 경우 정밀구조해석을 통하여 그 효과를 예측할 수 있을 것으로 판단된다.