착상을 고려한 가정용 냉동/냉장고 증발기의 열전달 성능

Heat Transfer Performance of Evaporator Used in a Domestic Refrigerator/Freezer Under Frosting Condition

  • 이장석 (한양대학교 대학원 기계공학과) ;
  • 이관수 (한양대학교 기계공학부)
  • Lee Jang-Seok (Graduate School, Department of Mechanical Engineering, Hanyang University) ;
  • Lee Kwan-Soo (School of Mechanical Engineering, Hanyang University)
  • 발행 : 2005.01.01

초록

In this study, the air-side heat transfer coefficients of several types of evaporators in the household freezer/refrigerators are investigated. The types considered in this work are: discrete flat plate fin-and-tube type(in-lined tube array), continuous flat plate fin-and-tube type(staggered tube array), and spine fin-and-tube type(in-lined tube array). The heat transfer correlations obtained from this study for each heat exchangers could expect heat transfer coefficients less than $5\%$ of errors. The result indicates that the air-side heat transfer performance of spine fin-and-tube type evaporator shows the highest value under dry conditions, but discrete flat plate fin-and-tube type evaporator shows the highest value among these three evaporators under frosting conditions.

키워드

참고문헌

  1. Kim, N-H., Youn, J-H., and R. L. Webb, 1997, Heat transfer and friction correlations for wavy plate fin-and-tube heat exchangers, J. Heat Transfer, Vol. 119, pp. 560-567 https://doi.org/10.1115/1.2824141
  2. Wang, C. C., Lee, W. S., Sheu, W. J.. and Chang, Y. J., 2001, Parametric study of air-side performance of slit fin-and-tube heat exchangers in wet conditions, J Mechanical Engineering Science(Part C), Vol. 214, No. 9, pp. 1111-1121
  3. Wang, C. C., Lee, C. J.. Chang, C. T., and Lin, S. P., 1999, Heat transfer and friction correlation for compact louvered fin-and- tube heat exchangers, J. Heat Mass Transfer, Vol. 42, pp. 1945-1956 https://doi.org/10.1016/S0017-9310(98)00302-0
  4. Jhee, S., Lee, K. S. and Kim, W. S., 2002, Effect of surface treatments on the frosting/defrosting behavior of a fin-tube heat exchanger, Int, J. Refrigeration, Vol. 25, No. 8, pp. 1047-1053 https://doi.org/10.1016/S0140-7007(02)00008-7
  5. Yun., J. Y. and Lee, K. S., 1999, Investigation of heat transfer characteristics on various kinds of fin-and-tube heat exchangers with-interrupted surfaces, Int. J. of Heat and Mass Transfer, Vol. 42, No. 13, pp. 2375-2385 https://doi.org/10.1016/S0017-9310(98)00310-X
  6. Cheong, A. S., 1989, Prediction of heat transfer performance of a heat exchanger based on test of a small sample, SAE Paper No. 890227
  7. Domanski, P. A., 1991, Simulation of an evaporator with nonuniform one-dimensional air distribution, ASHRAE Transactions : Symposia, pp. 793-802
  8. Schmidt, T. E., 1949, Heat transfer calculations for extended surfaces, Refrigerating Engineering, Vol. 57, pp. 351-357
  9. Rich. D. G., 1973, The effect of fin spacing on the heat transfer and friction performance of multi-row, smooth plate fin-and-tube heat exchangers, ASHRAE Transactions, Vol. 79. No. 2, pp. 137-145