Decoupling Control Design for Variable Speed Refrigeration System of a Ship

  • Hua, Li (Department of Refrigeration and Air-Conditioning Engineering, Graduate School, Pukyong University) ;
  • Jeong, Seok-Kwon (Division of Mechanical Engineering, Pukyong National University) ;
  • Yoon, Jung-In (Division of Mechanical Engineering, Pukyong National University)
  • Published : 2006.11.30

Abstract

In this paper, we suggest decoupling control method based on general PI control law to control variable speed refrigeration system of the ship effectively. In the variable speed refrigeration system, the capacity and the superheat are controlled by inverters and electronic expansion valves respectively for saving energy and improving cost performance. Thus, we propose decoupling model to eliminate the interfering loop between capacity and superheat at first. Next, we design PI controller to control capacity and superheat independently and simultaneously. Finally the control performance was investigated through some experiments. The experimental results show that the PI control design can obtain good control performance under the adjustable control reference and thermal load variation.

Keywords

References

  1. Jongmin Choi, Yongchan Kim and Jinho Ha, 'Experimental study on superheat control of a variable speed heat pump' SAREK, Vol. 13, No. 4, pp. 233-241, 2001(in Korean)
  2. A. Outtagarts, P. Haberschill, M. Lallemand, 'The Transient Response of an Evaporator Fed Through an Electronic Expansion Valve', International Journal of Energy Research, Vol. 21, pp. 793-807, 1997 https://doi.org/10.1002/(SICI)1099-114X(199707)21:9<793::AID-ER297>3.0.CO;2-P
  3. Yoon, S. H. and Chang, H. W., 'Empirical modeling and control performance simulation of an inverter heat pump system', Proceedings of the SAREK, pp. 725-730, 2001(in Korean)
  4. LI HUA and S. K. Jeong, 'An experimental model for decoupling control of a variable speed refrigeration system', KSPSE, Vol. 10, No. 3, pp. 81-87, 2006(in Korean)