Flexural Analysis of Reinforced Concrete Members Strengthened with FRP Systems Based on Strength Method

FRP 시스템으로 보강한 철근콘크리트 부재의 휨 해석

  • Received : 2006.01.05
  • Published : 2006.03.30

Abstract

Strength method for determining nominal moment capacity of reinforced concrete members is also assumed to be suitable for strengthened members with FRP system. If the internal tensile forces of the strengthened member from steel and FRP is insufficient, the FRP system strain might become greater than its ultimate tensile strain which makes the strength method a contradiction and unapplicable. The experimental results of 27 strengthened beams with carbon fiber sheets which have relatively lower tensile forces from steel and FRP show that not only concrete compressive strain is lower than 0.003 but also measured ultimate moment was lower than nominal moment using the strength method.

FRP 시스템으로 보강된 철근콘크리트 단면 대부분이 철근콘크리트로 구성되어 있어 휨해석 및 휨설계를 직사각응력블록을 이용한 강도설계법에 의존하는 경향이 있다. 그러나, 보강단면의 인장철근 및 FRP시스템에 의한 인장력이 부족한 단면의 FRP 시스템의 변형률이 인장파단변형률을 초과하면 강도설계법을 적용할 수 없는 해석상 모순에 빠져든다. 인장철근과 탄소섬유시트에 의한 인장력이 낮은 탄소섬유시트 보강보 실험에서 콘크리트 최대압축변형률이 0.003보다 낮은 것으로 측정되었을 뿐 아니라 최대휨모멘트는 강도설계법으로 산정된 공칭휨모멘트보다 작은 것으로 측정되어, FRP 시스템 보강단면의 공칭휨모멘트 산정에 강도설계법의 적용한계가 있는 것으로 나타났다.

Keywords

References

  1. 박대효, 부준성, "밑면 및 옆면 섬유시트로 보강된 철근콘크리트 보의 휨 해석," 대한토목학회논문집, 22권 5A호, 2002, pp. 1045-1057.
  2. 박정일, 조백순, 안상호, 유영찬, "섬유시트-강판 복합플레이트 보강 철근콘크리트 보의 휨성능에 관한 실험적 연구," 2004년 대한토목학회학술발표회논문집, pp. 3144- 3149.
  3. 정진환, 김성도, 조백순, 이우철, "탄소섬유시트로 보강된 RC 보의 공칭휨모멘트 - 1. 실험적 연구," 대한토목학회논문집, 23권 5A호, 2003. 9, pp. 921-929.
  4. 한국건설기술연구원, "건축구조물 보수.보강공법의 성능 평가에 관한 연구," R&D/99-건축07, 2001, pp. 545.
  5. 홍건호, 신영수, "RC 구조물에 적용된 부착식 휨보강공법의 보강성능 평가," 한국콘크리트학회논문집, 2003, 15권, 1호, pp. 78-86.
  6. ACI Committee 440, Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures, American Concrete Institute, Detroit, Michigan, 2002, pp. 79.
  7. Bencardino, F., Spadea, G., and Swamy, N., "Strength and Ductility of Reinforced Concrete Beams Externally Reinforced with Carbon Fiber Fabric," ACI Structural Journal, V. 99, No. 2, 2002. March-April, pp. 163-171.
  8. Brena, S. F., Bramblett, R. M., Wood, S. L., and Kreger, M. E., "Increasing Flexural Capacity of Reinforced Concrete Beams Using Carbon Fiber-Reinforced Polymer Composites," ACI Structural Journal, V. 100, No. 1, 2003. Jan-Feb., pp. 36-46.
  9. El-Mihilimy, M. T. and Redesco, J. W., "Analysis of Reinforced Concrete Beams Strengthened with FRP Laminates," Journal of Structural Engineering, Vol. 126, No. 6, 2000, pp. 684-691. https://doi.org/10.1061/(ASCE)0733-9445(2000)126:6(684)
  10. Grace, N. F., Ragheb, W. F., and Abdel-Sayed, G., "Flexural and Shear Strengthening of Concrete Beams Using New Triaxially Braided Ductile Fabric," ACI Structural Jouranl, V. 100, No. 6, 2003. Nov.-Dec., pp. 804-814.
  11. Ziraba, Y. N., Bsluch, M. H., Sharif, A. M., Azad, A. K., and Al-Sulaimani, G. J., "Guidelines toward the Design of Concrete Beams with External Plates," ACI Structural Journal, Vol. 91, No. 6, pp. 639-646.