The wall of thermal vacuum chamber which is used for the satellite thermal balance test doesn't absorb satellite's IR emission perfectly and reflects some part of that. It is estimated that small thermal vacuum chamber has relatively larger wall effect than the big one. The small thermal vacuum chamber is required for the small satellite test to reduce the test cost. A quantitative analysis was carried out to investigate the chamber wall effect. As a result, temperature errors caused by chamber wall effect was calculated, and the temperature data acquired in the thermal balance test have been compensated. By defining the optimized area ratio between chamber surface and satellite surface area, the baseline to be able to determine the minimum size of thermal vacuum chamber was established to minimize the wall effect. Also, theoretical analysis about transparent material coating which can reduce the chamber wall effect is conducted.

위성 열평형 시험에 사용하는 열진공 챔버의 벽은 흑체 거동을 하는 우주공간과는 달리 위성의 복사 에너지를 완벽하게 흡수하지 못하고 일부를 반사한다. 챔버의 크기가 작을수록 이러한 챔버 벽 효과는 커지는 것으로 알려져 있다. 이것은 시험비용을 줄이기 위해 대형 챔버를 사용하기 힘든 소형위성의 개발에 걸림돌이 된다. 본 연구에서는 챔버 벽 효과를 예측하고 이를 보정하기 위한 정량적인 분석을 진행하였다. 그 결과로 챔버 벽 효과에 의한 온도 오차를 계산하여 시험 데이터를 보정할 수 있게 하였다. 또, 최적 면적비를 정의하여 소형위성의 열평형 시험용 열진공 챔버의 크기를 정하는데 기준을 마련하였다. 덧붙여 챔버 벽을 투명한 재질로 코팅하여 챔버 벽 효과를 줄일 수 있는 방안에 대해 이론적인 분석을 수행하였다.

Keywords

References

  1. 장영근, 이동호 '인공위성 시스템 설계공학', 경문사, 1997, p. 451
  2. 김지영, 이동호, 최준민, 최석원, '열진공 시험의 가속화와 수치모사에 관한 연구', 한국항공우주학회지, 28권, 2호, 2000, pp 145-153
  3. Robert Siegel, John R. Howell, 'Thermal Radiation Heat Trasnfer', McGraw-Hill, 1972, pp. 59-62
  4. Frank P. Incropera, David P. Dewiit, 'Fundamentals of Heat and Mass Transfer', 5th Ed., WILEY & SONS, 2003, pp. 800-812
  5. 일반물리학 교재 연구회, '일반물리학', 광림사, 2000,pp. 613-616.
  6. 정기수, '물리의 이해', http://lphysica.gsnu.ac.kr/