산업용 전기집진기 내 유동 균일성에 대한 입구 디퓨저 확장각의 영향

Effect of Inlet Diffuser-Angle for Flow Uniformity of Industrial Electrostatic Precipitators

  • 권현구 (연세대학교 대학원 기계공학과) ;
  • 박석환 (연세대학교 대학원 기계공학과) ;
  • 조형희 (연세대학교 기계공학과) ;
  • 박기서 ((주)한국코트렐)
  • Kwon Hyun-Goo (Graduate School of Mechanical Engineering, Yonsei University) ;
  • Park Suk-Hwan (Graduate School of Mechanical Engineering, Yonsei University) ;
  • Cho Hyung-Hee (School of Mechanical Engineering, Yonsei University) ;
  • Park Ki-Seo (Korea Cottrell Co., Ltd.)
  • 발행 : 2006.04.01

초록

Industrial electrostatic precipitators require a highly uniform velocity distribution in the collecting chamber. Increasing divergence angle of a diffuser makes a non-uniformity flow distribution characteristics on the diffuser exit. This paper provides CFD results of optimum positions and opening rates of perforated plates which were installed in the electrostatic precipitator. The considered divergence angels were 60 degree and 90 degree. In 90 degree diffuser, a blanking method was used.

키워드

참고문헌

  1. Ward-Smith, A. J., Lane, D. L., Reynolds, A. J., Sahin, B. and Shawe, D. J., 1991, Flow regime in wide-angle screen diffusers, Int. J. Mech. Sci., Vol.33, No.1, pp. 41-54 https://doi.org/10.1016/0020-7403(91)90026-Y
  2. Sahin, B. and Ward-Smith, A. J., 1990, Effect of perforated plates on wide-angle diffuserexit velocity profiles, J. Wind Eng. and Industrial Aero., Vol. 34, pp. 113-125 https://doi.org/10.1016/0167-6105(90)90139-4
  3. Noui-Mehidi, M. N., Wu, J., Sutalo, I. D. and Grainger, C, 2005, Velocity distribution downstream of an asymmetric wide-angle diffuser, Exp. Thermal and Fluid Sci., Vol. 29-6, pp. 649-657
  4. Schubauer, G. B. and Spangenberg, W. G., 1943, Effect of screens in wide-angle diffusers, National Advisory Committee for Aeronautics, TN No. 1610
  5. Sahin, B. and Ward-Smith, A. J., 1987, The use of perforated plates to control the flow emerging from a wide-angle diffuser, with application to electrostatic precipitator design, Heat and Fluid Flow, Vol. 8, No.2, pp. 124-13l https://doi.org/10.1016/0142-727X(87)90011-7
  6. Sahin, B., 1989, Pressure losses in an isolated perforated plate and jets emerging from the perforated plate, Int. J. Mech. Sci., Vol. 31, No.1, pp, 51-61 https://doi.org/10.1016/0020-7403(89)90118-5
  7. Sahin, B. and Ward-Smith, A J., 1993, The pressure distribution in and flow characteristics of wide-angle diffusers using perforated plates for flow control with application to electrostatic precipitators, Int. J. Mech. Sci., Vol. 35, No.2, pp.117-127 https://doi.org/10.1016/0020-7403(93)90070-B
  8. Sahin, B., Ward-Smith, A. J. and Lane, D., 1995, The pressure drop and flow characteristics of wide-angle screen diffuser of large area ratio, J. Wind Eng. and Industrial Aero., Vol. 58, pp, 33-50 https://doi.org/10.1016/0167-6105(95)00018-M
  9. Speziale, C. G. and Thangamn, S., 1992, Analysis of an RNG based turbulence model for separated flows, Int. J. Eng. Sci., Vol. 30, No. 10, pp. 1379-1388 https://doi.org/10.1016/0020-7225(92)90148-A
  10. EP2 Industrial Gas Cleaning Institute Specifications, U.S.A, 1973