Application of Rechlorination for Adequate Disinfection Ability in Water Distribution System

관로 내 적정소독능 확보를 위한 재염소 기법의 적용

  • Received : 2006.06.20
  • Accepted : 2006.10.11
  • Published : 2006.10.15

Abstract

Disinfectant residual should be maintained to achieve biological stability during distribution of treated water. The wide distribution of retention times associated with storage and transport of water in a network and the reactivity of disinfectants make it difficult to maintain adequate residuals at critical locations. Rechlorination at some intermediate locations may reduce the total disinfectant dose while keeping residuals within specified limits throughout the water distribution system. In order to select the adequate location of rechlorination for achieving to maintain of residual chlorine throughout the distribution system, EPANET was used in this study. EPANET was well predicted chlorine transport and residual loss in the distribution system. Location of rechlorination was selected to maintain 0.4mg/L of residual chlorine throughout a water distribution system by field investigation and model simulation. The quantity of chlorine may reduced 36.7% and provided smooth residual between 0.42 and 0.60mg/L, when rechlorination would be used continuously at strategic location within the distribution system.

Keywords

References

  1. Biswas P. and Clark R.M. (1993) A Model for Chlorine Concentration Decay in Pipes, Wat. Res., 27(12), pp. 1715-1724 https://doi.org/10.1016/0043-1354(93)90108-T
  2. Boccelli, D.L., Trybv, M.E., Uber, J.G., Rossman, L.A., Zierolf, M.L., and Polycarpou, M.M. (1998) Optimal Scheduling of Booster Disinfection in Water Distribution Systems. J. Water Resour. Plan. Manage., 124(2), pp. 99-111 https://doi.org/10.1061/(ASCE)0733-9496(1998)124:2(99)
  3. Chambers V.K., Creasy J.D. and Joy J.S. (1995) Modelling Free and Total Chlorine Decay in Potable Water Distribution Systems, Aqua, 44(2), pp. 60-69
  4. Clark, R.M. and Haught, R.C. (2005) Characterizing Pipe Wall Demand: Implications for Water Quality Modeling, J. Water Resour. Plan. Manage., 131(3), pp. 208-217 https://doi.org/10.1061/(ASCE)0733-9496(2005)131:3(208)
  5. Haas, C.N. (1999) Benefits of Employing a Disinfection Residual, Aqua, 48(1), pp. 11-15
  6. Hallama, N.B., Westa, J.R., Forstera, C.F., Powell, J.C. and Spencer, I. (2002) The Decay of Chlorine associated with the Pipe Wall in Water Distribution Systems, Wat. Res., 36(14), pp.3479-3488 https://doi.org/10.1016/S0043-1354(02)00056-8
  7. Hua, F., West, J.R., Barker, R.A. and Forster, C.F. (1999) Modeling of Chlorine Decay in Municipal Water Supplies, Wat. Res., 33(12), pp. 2735-2746 https://doi.org/10.1016/S0043-1354(98)00519-3
  8. Jadas-Hecart A., El Moher A., Stitou M., Bouillot P. and Legube B. (1992) The Chlorine Demand of a Treated Water, Wat. Res., 26(8), pp. 1073-1084 https://doi.org/10.1016/0043-1354(92)90143-R
  9. LeChevallier, M.W. (1999) The Case for Maintaining a Disinfectant Residual, AWWA, 91(1), pp. 86-94
  10. Powell, J.C., Hallam, N.B., West, J.R., Forster, C.F. and Sirnms. J. (2000) Factors which Control Bulk Chlorine Decay Rates, Wat. Res., 34(1)pp. 117-126 https://doi.org/10.1016/S0043-1354(99)00097-4
  11. Prasad, T. D., Walters, G. A. and Savic, D. A. (2004) Booster Disinfection of Water Supply Networks: Multiobjective Approach, J. Water Resour. Plan. Manage., 130(5), pp. 367-376 https://doi.org/10.1061/(ASCE)0733-9496(2004)130:5(367)
  12. Propato, M. and Uber, J.G. (2004) Linear Least-squares Formulation for Operation of Booster Disinfection Systems, J. Water Resour. Plan. Manage., 130(1), pp. 53-62 https://doi.org/10.1061/(ASCE)0733-9496(2004)130:1(53)
  13. Rossman, L. A. (2000) EPANET Version 2 User's Manual, Drinking Water Research Division, USEPA, Cincinnati
  14. Tryby, M.E., Boccelli, D.L., Uber, J.G. and Rossman L.A. (2002) Facility Location Model for Booster Disinfection of Water Supply Networks, J. Water Resour. Plan. Manage., 128(5), pp. 322-333 https://doi.org/10.1061/(ASCE)0733-9496(2002)128:5(322)
  15. Vasconcelos, J.J., Boulos, P.F., Grayman, W.M., Kiene, L., Wable O., Biswas, P., Bhari, A., Rossman, L.A., Clark, R.M., and Goodrich, J. A. (1996) Characterisation and Modeling of Chlorine Decay in Distribution Systems, AWWARF
  16. Zhang G.R., Kiene L., Wable O., Chan U.S. and Duguet J.P. (1992) Modelling of Chlorine Residual in the Water Distribution Network of Macao, Enuiron. Technol., 13(10), pp.937-946