실물대모형 및 1/5, 1/10축소모형의 자연채광 성능평가에 관한 비교분석

Comparative Daylighting Performance Analysis of Offices in 1/10, 1/5 Scale Models and Mock-up Model

  • 백승헌 (경희대학교 대학원) ;
  • 김정태 (경희대학교 건축공학과(산학협력기술연구원))
  • 발행 : 2006.12.30

초록

Mock-up model can be applied to measure accurate performance data but difficult to apply the variables in experiment. There can be a slight experiment errors in Scale model, but various parameters can be applied for a objective experiment. This paper aims to compare the daylighting performance in 1, 1/5, 1/10 scale model of offices and analyze the experiment errors to certificate the influence of model experiment. To analyse daylighting performance, a comparison of a Mock-up model, sized $12.0m(w){\times}7.2m(l){\times}3.7m(h)$, designed for experimentation of daylighting systems and its 1:5, 1:10 scale model. It has an identical configuration of reference room and the test room. For the test room, the lightshelf system was designed as Micro-4 reflective material. To assess work plane illuminance and light factor, photometric sensors of each room were installed at work-plane(6 points) and exterior horizontal illuminance (1 point). And luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio and luminance are discussed.

키워드

참고문헌

  1. Schiler, M. (Ed.), 1987. Simulating Daylight with Architectural Models, Daylighting Network of North America. University of Southern California, Los Angeles, USA
  2. Love, J.A., Navvab, M., 1991. Daylighting estimation under real skies: a comparison of full-scale photometry and computer simulation. Journal of Illuminating Engineering Society 20 (1), 140. 156, IESNA (USA)
  3. Cannon-Brookes, S.W.A., 1997. Simple scale models for daylighting design: analysis of sources of error in illumination prediction. Lighting Research and Technology 29, 135. 142, CIBSE (UK) https://doi.org/10.1177/14771535970290030901
  4. Thanachareonkit, A., Comparing daylighting performance assessment of buildings in scale models and test modules, Solar Energy 79, 2005, pp.168-182 https://doi.org/10.1016/j.solener.2005.01.011
  5. 김정태 외, Mock-up model을 이용한 경사형광선반 채광시스템의 개발 및 채광성능평가에 관한 연구, 한국태양에너지학회 논문집, Vol.24, No.2, 2004, pp.39-50
  6. 정인영, 최상현, 김정태, 첨단채광시스템 실험용 Mock-up 모형의 형상 및 모니터링 프로토콜 시스템에 관한 비교분석, 한국생태환경건축학회 논문집, Vol.4, No.1, 2004.3, pp.11-20
  7. 정인영, 김정태, 축소모형을 이용한 분할형 유리투과체 창호시스템의 채광성능실험, 한국생태환경건축학회 논문집, Vol.4, No.4, 2004.12, pp.61-68
  8. 백승헌, 신화영, 한현주, 김정태, 모형축척에 따른 사무소 공간의 자연채광 성능에 관한 비교분석, 한국생태환경건축학회 추계학술발표대회 논문집, 제6권 제2호, 2006.11, pp.191-194