Experimental Study on Natural Ventilation Performance of Double Facade System in Heating Period

난방기 중 이중외피 시스템의 자연환기 성능분석에 관한 실험적 연구

  • 이건호 (한국건설기술연구원 건축연구부) ;
  • 김현수 (한국건설기술연구원 건축연구부) ;
  • 고영우 (삼성물산 건설부문 건축기술팀) ;
  • 손영주 (삼우EMC 외장사업부)
  • Published : 2006.06.30

Abstract

A Double Facade System(DFS) is well known as an innovative solution of ecological facade in the west european countries. There are more than 200 various realized DFS in Germany. At the same time, the korean engineers have researched to find out the physical advantages of DFS in the moderate korean climate, which has a very humid summer with high temperature and a dry winter with low temperature. For example, the monthly mean temperature in Korea comes up to 28K, while that in Germany comes up to only 19K. That is, why a other solution of DFS is needed in Korea. This study has experimented the physical performance of the natural ventilation in the heating period. The preheating function of the cold air by DFS can improve no doubt the performance of the natural ventilation at the cold season as well as spring and autumn. The physical difference between single and double facade on natural ventilation has been tested at the newly constructed laboratory, which can turn $360^{\circ}$ to confirm the characteristic of a facade with the various directions. The results show the natural ventilation of the DFS has definitely much more comfortable than that of the single facade system. The air velocity of the inflow as well as the air temperature in the DFS provide a more stable condition than in the SFS. The theoretical limit(air velocity max 0.2m/s, air temperature min. $18^{\circ}C$, temperature difference between 100mm and 1700mm height max. 3K) on the indoor comfortableness doesn't go over in the DFS. On the other hand, the SFS showed an unstable condition with an excess of comfortableness limit on air velocity as well as temperature. In view of the researching results so far achieved, the research came to a conclusion, that the DFS can provide a more comfortable indoor condition by the preheating in the heating period than a SFS, and the period of natural ventilation in winter time could be definitely increased at the DFS.

Keywords

References

  1. 김현수 외, 복합기능 생태적 건물외피 조성 기술 개발 I, II, III, 한국건설기술연구원, 2003, 2004, 2005
  2. Daniels K., Technologie des oekologischen Bauens, Birkhaeuser, Berlin, 1999
  3. Oesterle 외, Doppelschalige Fassaden, Ganzheitliche Planung, Callwey, Muenchen, 1999
  4. Lee K., Untersuchung zur Einsatzmoeglichkeit von Doppelfassaden bei hohen Verwaltungsbauten mit Glas- fassaden im extremgemaessigten Klimagebiet, Berlin, 2003
  5. Olaf Z., Grenzen der thermischen Last bei Fenster-lueftung in Buerogebaeude, TU-Berlin, 2000
  6. Blum 외, Doppelfassaden, Ernst & Sohn Verlag, Berlin, 2001