DOI QR코드

DOI QR Code

Measurement of Wavefront Aberrations in Off-Axis Parabolic Mirrors and its Dependence on the Misalignment

레이저 빔의 파면 측정을 통한 비축 포물 거울의 성능 평가 및 정렬 오차 민감도에 관한 연구

  • Jeong, Tae-Moon (Femtoscience Lab, Advanced Phhotonics Research Institute, GIST) ;
  • Choi, Il-Woo (Femtoscience Lab, Advanced Phhotonics Research Institute, GIST) ;
  • Ko, Do-Kyeong (Femtoscience Lab, Advanced Phhotonics Research Institute, GIST) ;
  • Lee, Jong-Min (Femtoscience Lab, Advanced Phhotonics Research Institute, GIST)
  • 정태문 (광주과학기술원 고등광기술연구소 펨토과학 연구실) ;
  • 최일우 (광주과학기술원 고등광기술연구소 펨토과학 연구실) ;
  • 고도경 (광주과학기술원 고등광기술연구소 펨토과학 연구실) ;
  • 이종민 (광주과학기술원 고등광기술연구소 펨토과학 연구실)
  • Published : 2006.03.01

Abstract

Wavefront aberrations of a laser beam that was reflected from an off-axis parabolic (OAP) mirror were measured to evaluate the optical performance of the OAP mirror. For a diamond turned OAP mirror, the root-mean-square (rms) value of higher-order aberrations was only $0.03{\mu}m$ for the laser beam size of about 34 mm. The other OAP mirror which was polished at a domestic company had the rms value of higher-order aberrations of $2.07{\mu}m$ for the same beam size. Although the diamond turned OAP mirror was well fabricated to have a small amount of aberrations, the aberrations were induced by the misalignment of the OAP mirror. Especially, 0 degree astigmatism increased with the sensitivity of $0.372{\mu}m/mrad$ when the OAP mirror was tilted in the tangential plane, which agreed well with the calculated results using a commercial ray tracing software.

본 논문에서는 비축 포물 거울을 통과한 레이저 빔의 파면을 측정하는 방식으로 국내 및 국외에서 제작된 비축 포물 거울을 평가하였으며, 이로부터 비축 포물 거울의 집속 성능 및 정렬 민감도를 측정하였다. 국외에서 제작된 비축 포물 거울은 직경 약 34 mm의 레이저 빔에 대해 고차 파면 수차(higher-order aberration)의 rms 값이 $0.03{\mu}m$ 정도로 작아 광학적으로 좋은 품질을 갖는 것으로 판명되었다. 국내에서 제작된 비축 포물 거울은 같은 34 mm의 레이저 빔에 대해 고차 파면 수차의 rms 값이 $2.01{\mu}m$나 관측되어 아직 개선이 필요한 것으로 보인다. 또한, 비축 포물 거울의 회전 정렬 오차에 대한 비점수차(astigmatism)의 민감도를 측정한 결과 회전 정렬 오차에 대한 비점수차의 민감도는 $0.371{\mu}m/mrad$인 것으로 관측되었다. 이는 광선 추적 소프트웨어를 사용하여 계산한 값과 거의 같은 양으로 이러한 비점수차의 정렬 민감도 측정은 비축 포물 거울을 정렬하는데 도움을 줄 것으로 생각된다.

Keywords

References

  1. R.A. Snavely et al., 'Intense High-Energy Proton Beams from Petawatt-Laser Irradiantion of Solids,' Phys. Rev. Lett., vol. 85, no. 14, pp. 2945-2948, 2000 https://doi.org/10.1103/PhysRevLett.85.2945
  2. V. Malka et al., 'Electron Acceleration by a Wake Field Forced by an Intense Ultrashort Laser Pulse,' Science vol. 298, pp. 1596-1600, 2002 https://doi.org/10.1126/science.1076782
  3. M.A. Lieb and A.J. Meixner, 'A high numerical aperture parabolic mirror as imaging device for confocal microscopy,' Opt. Express vol. 8, no. 7, pp. 458-474, 2001 https://doi.org/10.1364/OE.8.000458
  4. P. Varga and P. Torok, 'Focusing of electromagnetic waves by paraboloid mirror. I. Theory,' J. Opt. Soc. Am. A, vol. 17, no. 11, pp. 2081-2089, 2000 https://doi.org/10.1364/JOSAA.17.002081
  5. P. Varga and P. Torok, 'Focusing of electromagnetic waves by paraboloid mirror. II. Numerical results,' J. Opt. Soc. Am. A, vol. 17, no. 11, pp. 2090-2095, 2000 https://doi.org/10.1364/JOSAA.17.002090
  6. R. Tyson, Principles of Adaptive Optics (Academic Press, San Diego, USA, 1998), pp. 141-173
  7. T.M. Jeong, M. Menon, and G. Yoon, 'Measurement of wave-front aberration in soft contact lenses by use of a Shack-Hartmann wavefront sensor,' Appl. Opt. 44, pp. 4523-4527, 2005 https://doi.org/10.1364/AO.44.004523
  8. J. Primot and N. Guerineau, 'Extended Hartmann test based on the pseudoguiding property of a Hartmann mask completed by a phase chessboard,' Appl. Opt., 39, no. 31, pp. 5715-5720, 2000 https://doi.org/10.1364/AO.39.005715
  9. J. Goodman, Introduction to Fourier Optics (McGraw-Hill Singapore, 1996), pp. 104-106
  10. A. Guirao, D. Williams, and I. Cox, 'Effect of rotation and translation on the expected benefit of an ideal method to correct eye's higher-order aberrations,' J. Opt. Soc. Am. A, vol. 18, no. 5, pp. 1003-1015, 2001 https://doi.org/10.1364/JOSAA.18.001003
  11. D. Malacara, Optical shop testing (Wiley-Interscience, New York, USA, 1992), chap. 13
  12. L. Thibos, R. Applegate, J. Schwiegerling, R. Webb, and VSIA standard taskforce members, 'Standards for reporting the optical aberrations of eyes,' in Vision Science and Its Applications, V. Lakshminarayanan, ed., Vol 35 of OSA Trends in Optics and Photonics Series (Optical Society of America, Washington, D.C., 2000), pp. 232-244
  13. M. Born and E. Wolf, Principles of optics (Cambridg University Press, Cambridge, UK, 1999), pp. 518-520