Abstract

This paper dealt with the performance evaluation and the diagnostic techniques of lightning arresters for DC electric traction vehicle. Field Measurements on the protective operation of lightning arresters against surge currents were carried out on running vehicles to acquire the data necessary for the diagnosis. The frequency and the magnitude of surge events were analyzed. Surge currents of $1\sim3$ times were recorded in one running service route and their magnitudes were ranges of $150A\sim2kA$. Also, an acceleration experiment on a lightning arrester by the standard lightning impulse current of 8/20 us and 5 kA was performed to know the aging characteristics. After the surge current application of 3,000 times, the reference voltage decreased by 4.5 %, and the leakage current was below 10 uA at the continuous operating voltage and about 50 uA at the rated voltage. From the experimental results, we propose a decision level of leakage current for the arrester used in this paper and designed an arrester tester which analyzes arrester condition by the magnitude of leakage current.

Keywords

References

  1. Mazen Abdel-Salam et al., 2000, High-Voltage Engineering Theory and Practice, pp.447-453
  2. W.C.Hart, E.W.Malone, 1998, Lightning and Lightning Protection, pp.1.1-2.15
  3. Peter Hasse1, 2004, Overvoltage protection of low-voltage systems, The Institution of Electrical Engineers, pp.67-125
  4. P. P. Barker et al., 1993, 'Characteristics of Lightning Surge Measured at Metal Oxide Distribution Arresters', IEEE Transactions on Power Delivery, Vol.8, No.1, pp.301-310 https://doi.org/10.1109/61.180350
  5. T. K. Gupta, 1990, 'Application of zinc oxide varistors', Journal of the American Ceramic Society, Vol.73, No.7, pp.1817-1840 https://doi.org/10.1111/j.1151-2916.1990.tb05232.x
  6. O. Nigol, 1992, 'Methods for Analyzing the Performance of Gapless Metal Oxide Surge Arresters', IEEE Transaction on Power Delivery, Vol.7, No.3, pp.1256-1262 https://doi.org/10.1109/61.141839
  7. 길경석, 한주섭, 한문섭, 2004, '철도용 피뢰기의 열화진전에 관한 연구', 한국철도학회논문집, 제7권, 제4호, pp.307-311
  8. IEC 60099-4, 2003, Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems, International Electrotechnical Commission, pp.61-77
  9. 길경석, 한주섭, 김정배, 2003, '피뢰기 열화진단을 위한 저항분 누설전류의 측정장치', 대한전기학회논문지, 제52C권, 제10호, pp.469-476
  10. 길경석 외, 2002, '뇌충격전류에 의한 산화아연형 피뢰기 소자의 전기적 특성과 피뢰기 열화진단전문가 시스템', 대한전기학회논문지, 제51C권, 제4호, pp.152-157
  11. 길경석, 송재용, 박진길, 1999, '가스튜-브와 산화아연 바리스터의 PSpice 모델', 한국마린엔지니어링학회논문지, 제23권, 제2호, pp.150-158
  12. IEEE Working group 3.4.11, 1992, 'Modeling of Metal Oxide Arresters', IEEE Transaction on Power Delivery, Vol.7, No.1, pp.302-310 https://doi.org/10.1109/61.108922
  13. 길경석, 한주섭, 2000, '다중 뇌충격전류에 의한 산화아연형 피뢰기 소자의 특성변화', 대한전기학회논문지, 제51C권, 제4호, pp.685-690