평판관 열교환기 내 공기-물 2상류 분지

Distribution of Air-Water Two-Phase Flow in a Flat Tube Heat Exchanger

  • 발행 : 2006.09.01

초록

The air and water flow distribution are experimentally studied for a heat exchanger composed of round headers and 10 flat tubes. The effects of tube protrusion depth as well as mass flux, and quality are investigated, and the results are compared with the previous 30 channel results. The flow at the header inlet is annular. For the downward flow configuration, the water flow distribution is significantly affected by the tube protrusion depth. For flush-mounted geometry, significant portion of the water flows through frontal part of the header. As the protrusion depth increases, more water is forced to the rear part of the header. The effect of mass flux or quality is qualitatively the same as that of the protrusion depth. Increase of the mass flux or quality forces the water to rear part of the header. For the upward flow configuration, different from the downward configuration, significant portion of the water flows through the rear part of the header. The effect of the protrusion depth is the same as that of the downward flow. As the protrusion depth increases, more water is forced to the rear part of the header. However, the effect of mass flux or quality is opposite to the downward flow case. As the mass flux or quality increases, more water flows through the frontal part of the header. Compared with the previous thirty channel configuration, the present ten channel configuration yields better flow distribution. Possible explanation is provided from the flow visualization results.

키워드

참고문헌

  1. Watanabe, M., Katsuda, M. and Nagata, K., 1995, Two-phase flow distribution in multipass tube modeling serpentine type evaporator, ASME/JSME Thermal Engineering Conf., Vol. 2, pp. 35-42
  2. Tompkins, D. M., Yoo, T., Hrnjak, P., Newell, T. and Cho, K., 2002, Flow distribution and pressure drop inmicro-channel manifolds, 9th Int. Refrigeration and Air Conditioning Conference at Purdue, R6-4
  3. Vist, S. and Pettersen, J.. 2004, Two-phase flow distribution in compact heat exchanger manifolds, Exp, Thermal Fluid Sci., Vol. 28, pp. 209-215 https://doi.org/10.1016/S0894-1777(03)00041-4
  4. Lee, J. K. and Lee, S. Y., 2004, Distribution of two-phase annular flow at header-channel junctions, Exp. Thermal Fluid Sci., Vol. 28, pp. 217-222 https://doi.org/10.1016/S0894-1777(03)00042-6
  5. Cho, R., Cho, K. and Kim, Y., 2003, Mass flow rate distribution and phase separation of R-22 in multi-rnicrochannel tubes under adiabatic condition, 1st Int. Conf. Microchannels and Minichannels, pp.527-533
  6. Kim, N. R., Shin, T. R. and Sim, Y. S., 2006, Distribution of air-water two-phase flow in a header of aluminum flat tube evaporator, J. SAREK, Vol. 18, No.1, pp.55-66
  7. Rong, X., Kawaji, M. and Burgers, J. G., 1995, Two-phase header flow distribution in a stacked plate heat exchanger, FED-Vol. 225, Gas Liquid Flows, pp. 115-122
  8. Bernoux, P., Mercier, P. and Lebouche, M., 2001, Two-phase flow distribution in a compact heat exchanger, Proc. 3rd Int. Conf. Compact Heat Exchangers, pp.347-352
  9. Baker, O., 1954, Design of pipe lines for simultaneous flow of oil and gas, Oil and Gas Journal, Vol. 26, July