Evaluation of Performance of a Residential Air-Conditioning System Using Microchannel and Fin-and-Tube Heat Exchanger

마이크로채널과 핀 튜브 열교환기를 적용한 가정용 에어컨디셔너의 성능 평가

  • Yun, Rin (Department of Mechanical Engineering, Hanbat Notional University)
  • 윤린 (한밭대학교 기계공학과)
  • Published : 2007.01.10

Abstract

In this study the seasonal performance of a residential air conditioning system having either a fin-and-tube condenser or a microchannel condenser is experimentally investigated. A commercially available 7 kW capacity residential air conditioning system having a fin-and-tube condenser served as the base system. The test results show that the system with a microchannel heat exchanger has a reduced refrigerant charge amount of 10%, the coefficient of performance is increased by 6% to 10%, and the SEER is increased by 7% as compared with those of the base system. Moreover, the condensing pressure of the system is decreased by 100 kPa and the pressure drop across the condenser is decreased by 84%. The microchannel heat exchanger enhances the SEER of the residential air conditioning system by providing better heat transfers at reduced pressure drops.

Keywords

References

  1. Pettersen, J., Hafner, A. and Skaugen, G.,1998, Development of compact heat exchangers for CO2 air-conditioning systems, International Journal of Refrigeration, Vol.21, pp. 180-193 https://doi.org/10.1016/S0140-7007(98)00013-9
  2. Beaver, A. C., Yun, M. J., Bullard, C. W. and Hrnjak, P. S., 1999, An experimental investigation of transcritical carbon dioxide systems for residential air conditioning, ACRCCR-18
  3. Kirkwood, A. C., 1996, Modeling, design, and testing of a microchannel spilt-system air conditioner, MS Thesis, University Illinois, Urbana, IL, USA
  4. Hrnjak, P. S., 2000, Microchannel heat exchangers as evaporators, USNC/IIR Short Course on Analysis and Design of Microchannel Heat Exchangers, Purdue University
  5. Kim, J. H. and Groll, E. A, 2003, Performance comparison of a unitary split system using microchannel and fin-tube outdoor coils, ASHRAE Transactions, Vol. 109, Pt. 2, pp. 219-229
  6. Kim, M. H. and Bullard, C. W., 2002, Performance evaluation of a window room air conditioner with microchannel condensers, Journal of Energy Resources Technology, Vol. 124, pp.47-55 https://doi.org/10.1115/1.1446072
  7. Cho, J. P., Choi, Y. H., Kim, N. H. and Kim, J. H., 1999, Performance evaluation of PF-condenser adopted to package air-conditioner, Proceedings of the SAREK 1999 Winter Annual Conference, pp. 46-51
  8. Jeong, J. H., Chang, K. S., Kim, H., Kil, S. H. and Kim, H. K, 2004, Performance assessment of aluminum parallel flow condenser . applied to residential air-conditioner, Proceedings of the SAREK 2004 Winter Annual Conference, pp. 636-641
  9. Bae, T. S. and Han, C. S., 1996, A feasibility study on room air conditioner with parallel flow condenser, Proceedings of the SAREK 1996 Summer Annual Conference, pp. 402-407
  10. ARI, 1989, ARI Standard 210/240-89, Unitary air-conditioning and air-source heat pump equipment, Arlington, Va., Air-Conditioning and Refrigeration Institute