A Study on the Shaping Ability of Three Different Rotary Nickel-Titanium Instruments in Simulated Curved Root Canal

만곡 근관에서 다양한 엔진 구동형 Nickel-Titanium 파일의 근관 성형능력에 대한 연구

  • Kim, Kyoung-A (Department of Dentistry, School of Dentstry, Chonbuk National University) ;
  • Chon, Seong-Min (Department of Dentistry, School of Dentstry, Chonbuk National University) ;
  • Kwon, Su-Mi (Department of Dentistry, School of Dentstry, Chonbuk National University) ;
  • Lee, Kwang-Won (Department of Dentistry, School of Dentstry, Chonbuk National University) ;
  • Yu, Mi-Kyung (Department of Dentistry, School of Dentstry, Chonbuk National University)
  • 김경아 (전북대학교 치과대학 치과보존학교실) ;
  • 전성민 (전북대학교 치과대학 치과보존학교실) ;
  • 권수미 (전북대학교 치과대학 치과보존학교실) ;
  • 이광원 (전북대학교 치과대학 치과보존학교실) ;
  • 유미경 (전북대학교 치과대학 치과보존학교실)
  • Published : 2007.12.30

Abstract

I. Objectives The purpose of this study was to compare the shaping ability between the single length technique performed with Mtwo instruments (VDW, Munich, Germany) and the crown-down technique using K3 (SybronEndo, West Collins, CA, USA) and RaCe (FKG, La Chaux-de-Fonds, Switzerland) instruments. II. Materials & Methods Forty five curved canals in resin blocks were equally divided in to three groups. Group 1 (Mtwo) was instrumented used the full length of canal according to the manufacturer's instructions. The simulated canals was prepared to an instrument size of 35, 0.04 taper canal terminus. In group 2 (Race) and group 3 (K3) was instrumented in a crown-down manner and prepared to an instrument size of 30, 0.06 taper canal terminus. Pre- and post-instrumentation images were scanned and assessment of canal shape was completed with a computer image analysis program. Material removal was measured at 7 measuring points, beginning 1mm from the end point of preparation. Differenced of centering ratio were statistically analyzed using One-way ANOVA followed by Duncan's test. II. Results & Conclusion There was no significant difference on 1, 2, 3 and 7mm measuring point. At 4 and 5 measuring point, significant difference showed between the Mtow instruments and other two instruments. (p<0.05)

Keywords

References

  1. Schilder H. Cleaning and shaping the root canal. Dent Clin North Am 1974;18:269-296
  2. Schilder H. Filling root canals in three dimensions. Dent Clin North Am 1967;11:723-744
  3. Wildey WL, Senia ES, Montgomery S. Another look at root canal instrumentation. Oral Surg Oral med Oral Pahtol Oral Radial Endod 1992; 74:499-507 https://doi.org/10.1016/0030-4220(92)90303-8
  4. Skidmore AE, Bjorondal AM, Iowa IC. Root canal morphology of the human mandibular first molar. Oral Surg Oral med Oral Pahtol Oral Radial Endod 1971;32:778-784 https://doi.org/10.1016/0030-4220(71)90304-5
  5. Schneider SW. A comparison of canal preparation in straight and curved root canals. Oral Surg Oral med Oral Pahtol Oral Radial Endod 1971;2:271-275
  6. Walia HM, Brantley WA, Gerstein H. An initial investigation of the bending and torsional properties of Nitinol root canal files. J Endod 1988;14:346-351 https://doi.org/10.1016/S0099-2399(88)80196-1
  7. Espito Pt, Cunningham CJ. A comparison of canal preparation with nickel-titanium and stainless steel instruments. J Endod 1995;21:173-176 https://doi.org/10.1016/S0099-2399(06)80560-1
  8. 박한수, 이민구, 김종진, 이종엽. Profile을 이용한 만곡근관 형성시 근관형태에 관한 연구. 대한치과보존학회지 1999;24:633-637
  9. 고현정, 백승호. 수종의 Engine-driven Ni-Ti file과 stainless steel K-file을 이용한 근관 형성 후 근관의 조직형태학적 변화에 대한 연구. 대한치과보존학회지 2002;27:612-621
  10. Thompson SA, Dummer PMH. Shaping ability of ProFile .04 taper series 29 rotary nickel-titanium instruments in simulated canals. Part 1. International Endodontic Journal 1997;30:1-7 https://doi.org/10.1111/j.1365-2591.1997.tb01093.x
  11. Schafer E. Shaping ability of Hero 642 rotaty nickel titanium instruments and stainless steel hand K-Flexofiles in simulated cureved root canals. Oral Surg Oral med Oral Pahtol Oral Radial Endod 2001;92:215-220 https://doi.org/10.1067/moe.2001.114622
  12. Schafer E, Lohmann D. Efficiency of rotary nickeltitanium FlexMaster instruemts compared with stainless steel hand K - Flexofile. Part 1. Shaping ability in simulated curved canals. International Endodontic Journal 2002;35:505-513 https://doi.org/10.1046/j.1365-2591.2002.00513.x
  13. Peter OA. Current challenges and conceptsin the preparation of root canal systems: a review. J Endod 2004;30:559-571 https://doi.org/10.1097/01.DON.0000129039.59003.9D
  14. Schafer E, Florek H. Efficiency of rotary nickeltitanium K3 instruments compared with stainless steel hand K - Flexofile. Part 1. Shaping ability in simulated curved canals. International Endodontic Journal 2003;36:199-207 https://doi.org/10.1046/j.1365-2591.2003.00643.x
  15. Schafer E, Vlassis M. Comparative investigation of two rotary nickel-titanium instruments: ProTaper versus RaCe. Part 1. Shaping ability in simulated curved canals. International Endodontic Journal 2004;37:229-238 https://doi.org/10.1111/j.0143-2885.2004.00786.x
  16. Ayar LR, Love RM. Shaping ability of ProFile and K3 rotary Ni-Ti instruments when used in variable tip sequence in simulated curved root canals. International Endodontic Journal 2004;37:593-601 https://doi.org/10.1111/j.1365-2591.2004.00851.x
  17. Paque F, Musch U, Hulsmann M. Comparison of root canal preparation using RaCe and ProTaper rotary Ni-Ti instruments. International Endodontic Journal 2005;38:8-16 https://doi.org/10.1111/j.1365-2591.2004.00889.x
  18. Rangel S, Cremonese R, Bryant S, Dummer P. Shaping ability of RaCe rotary nickel-titanium instruments in simulated root canal. Journal of Endodontics 2005;31:460-463 https://doi.org/10.1097/01.don.0000148144.79173.aa
  19. Yoshimine Y, Ono M, Akamine A. The shaping effects of three nickel-titanium rotary instruments in simulated S-shaped canals. Journal of Endodontics 2005;31:373-375 https://doi.org/10.1097/01.don.0000140568.40462.43
  20. Calberson FL, Deroose CAJ, Hommez GM, Raes H, Demoor RJ. Shaping ability of $GT^{TM}$ Rotary Files in simulated resin root canals. International Endodontic Joumal 2002;35:607-614 https://doi.org/10.1046/j.1365-2591.2002.00540.x
  21. Eldeeb ME, Boraas JC. The effect of different files on the preparation shape of severely curved canals. International Endodontic Journal 1985;18:1-7 https://doi.org/10.1111/j.1365-2591.1985.tb00414.x
  22. Lim KC, Webber J. The validity of simulated root canals for the investigation of the prepared root canal shape. International Endodontic Journal 1985;18: 240-246 https://doi.org/10.1111/j.1365-2591.1985.tb00450.x
  23. Bonetti FI, Miranda ER, de Toledo LR, del Rio CE. Microscopic evaluation of three endodontic files pre and postinstumentation. Journal of Endodontics 1998;24:461-464 https://doi.org/10.1016/S0099-2399(98)80046-0
  24. Thompson SA, Dummer PM. Shaping ability of Quantec Series 2000 rotary nickel-titanium instruments in simulated root canals. Part 1. International Endodontic Journal 1998;31:259-267 https://doi.org/10.1046/j.1365-2591.1998.00151.x
  25. Bryant ST, Dummer PM, Pitoni C, Bourba M, Moghal S. Shaping ability of . 04 and .06 taper ProFile rotary nickel-titanium instruments in simulated root canal. International Endodontic Journal 1999;32;155-164 https://doi.org/10.1046/j.1365-2591.1999.00256.x
  26. Griffiths IT, Bryant ST, Dummer PM. Canal shapes produced sequentially during instrumentation with Quantec LX rotary nickel-titanium instruments: a study in simulated canals. International Endodontic Journal 2000;33:346-354 https://doi.org/10.1046/j.1365-2591.2000.00311.x
  27. Hyung-hwa Yun, Sung Kyo Kim. A Comparison of the shaping abilities of 4 nickel-titanium rotary instruments in simulated root canals. Oral Surg Oral med Oral Pahtol Oral Radial Endod 2003;95:228-233 https://doi.org/10.1067/moe.2003.92
  28. Jeong-Im Jo, Myoung-Uk Jin, Yong Kyoung Kim, Sung Kyo Kim. Change of Working length in curved canals by various instrumentation techniques. 대한치과보존학회지 2006;31(1):31-35 https://doi.org/10.5395/JKACD.2006.31.1.030
  29. Martin B, Zelada G, Varela P et al. Factors influencing the fracture of nickel titanium rotary instruments. International Endodontic Journal 2003; 36:262-266 https://doi.org/10.1046/j.1365-2591.2003.00630.x
  30. Sattapan B, Nervo G, Palamara J, Messer H. Defect in nickel titanium endodontic rotary files after clinical usage. Journal of Endodontics 2000;26: 161-165 https://doi.org/10.1097/00004770-200003000-00008
  31. Pruett JP, Clement DJ, Carnes DL. Cyclic fatigue testing of nickel-titanium endodontic instruments. Journal of Endodontics 1997;23:77-85 https://doi.org/10.1016/S0099-2399(97)80250-6
  32. Haikel Y, Serfaty R, Bateman G, Senger B, Allemann C. Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments. Journal of Endodontics 1999;25:434-440 https://doi.org/10.1016/S0099-2399(99)80274-X
  33. Gambarini G. Cyclic fatigue of ProFile rotary instruments after prolonged clinical use. International Endodontic Journal 2001;34:386-389 https://doi.org/10.1046/j.1365-2591.2001.00259.x
  34. G. Plotino, N. M. Grande, E. Sorici, V. A. Malagnino, F. Somma. A comparison of cyclic fatigue between used and new Mtwo Ni-Ti instruments. International Endodontic Journal 2006;39:716-723 https://doi.org/10.1111/j.1365-2591.2006.01142.x