초록

The membrane pilot plant has being operated in the Hyeondo pumping station to find the optimal operation technique of Gong-Ju membrane water treatment plant (WTP) which is constructing in $250m^3/d$ scale. The pilot plant was consisted of two trains which can treat $30,000m^3/d$ per train. First train was operated for one year under the condition of flux $1m^3/m^2{\cdot}d$ while the effects of flux variation and addition of powdered activated carbon(PAC) were evaluated in second train. The turbidity of membrane product water of first train which is operated on Flux $1m^3/m^2{\cdot}d$ was always below 0.05 NTU regardless of raw water turbidity. And also, the trance-membrane pressure(TMP) was maintained at $0.3{\sim}0.5kgf/cm^2$ for about 9 months and increased rapidly to $1.8kgf/cm^2$ which is maximum operating TMP. However, TMP was rapidly increased to $1.8kgf/cm^2$ within 2 months as flux was increased from 1 to $2m^3/m^2{\cdot}d$, especially, within 10 days under high turbidity(30~50NTU). This reault means that if Gongju membrane WTP is operated in flux $1m^3/m^2{\cdot}d$, chemical cleaning period can be maintained over 6 months. Only 10% of dissolved organic carbon (DOC) was removed in membrane process while the removal efficiencies of manganese and iron were 60% and 77% respectively. However, because only solid manganese and iron were removed in membrane process, an additional process for treating soluble manganese is required if souble manganese is high in raw water. 70% of 70ng/L 2-MIB which is causing taste & odor was removed in powdered activated carbon (PAC) tank with 50mg/L PAC which is design concentration of Gongju WTP. In addition, TMP was reduced with addition of 50mg/L PAC regardless of flux. Because TMP was not influenced even if 100mg/L PAC was added, the high taste and odor problem can be controled by additional injection of PAC.

키워드

참고문헌

  1. 김충환, 김한승, 김범수, 김형수 공역 (2006) 정수막, 동화기술. pp.78-80. 서울
  2. 김한승, 김충환, 오정익, 정범석 공역(2006), 수도막여과법 입문, pp.15-23. 동화기술
  3. 상하수도협회 (2005) 국내 막기술 발전을 위한 중장기 계획 수립, pp.49-55 상하수도협회
  4. 財團法人 水道技術研究センタ (2005) 環境影響低減化淨 水技術開發硏究 (e-Water)ーヵイドライン集. pp. 17-26, 財團法人 水道技術研究センタ, 東京
  5. Howe, K.J. and Clark, M.M. (2002) Coagulation pretreatment for membrane filtration, AWWARF & AWWA
  6. Kuberkar, V,T. and Davis, R.H. (2000) Modeling of fouling reduction by secondary membranes, J. Membrane Science, 168, pp.243-258 https://doi.org/10.1016/S0376-7388(99)00324-5
  7. Mallevialle J., Odendaal, P.E., and Wiesner, M.R. (1996) Watert treatment membrane process, AWWRF, Lyonnaise des Eaux & Water Reserach Commission of South Africa, McGraw-Hill, New York
  8. Pressdee, J.R., Veerapaneni, S., Shorney-Darby, H.L., Clement, J.A. and Van der Hoek, J.P. (2006) Integrated Membrane Filtration into Water Treatment System, AWWARF, AWWA & IWA, U.S.A
  9. Schafer, A.I., Schwicker, U., Fischer, M.M., Fane, A.G., and Waite, T.D. (2000) Microfiltration of colloids and natural organic mateer, J. Membrane Science, 171, pp. 151-172 https://doi.org/10.1016/S0376-7388(99)00286-0
  10. Schippers, J.C., Kruithof, J.C., and Nederlof, M.M.. (2004) Integrated Membrane System, AWWARF & AWWA, U.S.A