A Voltage Control Technique of Line-Interactive DVR Using 7-Level H-Bridge Inverter

7-레벨 H-Bridge 인버터를 이용한 Line-Interactive DVR의 전압제어

  • Published : 2007.04.01

Abstract

Recently, the interest on power quality has been hot issue because the equipments cause voltage disturbance and have become more sensitive to the voltage disturbance. Additionally, the reseach on power electronic equipments applying to the high power has been increased. This paper deals with Line-Interactive Dynamic Voltage Restorer(LIDVR) system using 7-Level H-Bridge inverter, which is one of the solutions to compensate the voltage disturbance and to increase the power of equipments. The LIDVR has the following advantages comparing to the DVR with the series injection transformer. It has the power factor near to unity under the condition of normal source voltage, can compensate the harmonic current of the load and the instant interruption, and has the fast response. First, the construction, the operation mode and algebraic modeling of LIDVR are reviewed. And then the voltage control algorithm is proposed to get the sinusoidal load voltage with constant amplitude. Finally, simulation and experiment results verify the proposed LIDVR system.

Keywords

References

  1. N,G. Hingorani, 'Introducing custom power,' IEEE spectrum , vol.32, pp. 41- 48, June 1995
  2. Hingorani N.G., 'Flexible AC Transmission System', IEEE Spectrum, pp.40-45, Apr. 1993
  3. 박종근, 한병문, 문승일, '송전용 FACTS 기기 개발 동향 UPFC의 개념과 송전계통 적용 현황,' 대한전기학회지, 제 47권 , 3호, pp.25-31, 1998
  4. 노대석, 김응상, 김재언, '배전계통기술의 신조류,' 대한전기학회지, 제49권, 4호, pp.31-39, 2000
  5. Math H. J. Bollen, Understanding Power Quality Problems, IEEE Press, 2000
  6. Arindam Ghosh and Gerard Ledwich, Power Quality Enhancement Using Custom Power Devices, Kluwer Academic Publishers, 2002
  7. F. Z. Peng, J. W. McKeever and D. J. Adams, 'A Power Line Conditioner Using Cascade Multilevel Inverters for Distribution Systems,' IEEE Trans. on Industry Applications, vol. 34, no. 6, pp. 1293-1298, Nov./Dec. 1998 https://doi.org/10.1109/28.739012
  8. F. Z. Peng, 'Application Issues of Active Power Filters,' IEEE Industry Application Magazine, pp.21-30, Sept./Oct. 1998
  9. J.G. Nielsen, F. Blaabjerg, 'Comparison of system Topologies for dynamic voltage restorers,' IEEE Industrial Application Society Annual Meeting, 2397-2403, 2001
  10. S Karve, 'Three of a Kind,' IEE Review, vol. 46, pp.27-31, March 2000
  11. Soren Rathmann, Henry A. Warner, 'New generation ups technology, The delta conversion principle,' IEEE IAS Conf. Rec., vol. 4, pp.2389-2395, 1996
  12. Weissbach et al, 'A combined uninterruptible power supply and dynamic voltage compensator using a flywheel energy storage system,' IEEE Trans. on Power Delivery, vol.16, pp.265-270, April 2001 https://doi.org/10.1109/61.915493
  13. N.H. Woodley, L. Morgan, A. Sundaram, 'Experience with an inverter-based dynamic voltage restorer,' IEEE Trans. on Power Delivery, vol.14, no.3pp.1181-1186, July 1999 https://doi.org/10.1109/61.772390
  14. S.S. Choi, B.H. Li, D.M. Vilathgamuwa, 'Dynamic voltage restoration with minimum energy injection,' IEEE Trans. on Power Systems, vol.15, no.1, pp.51-57, Feb. 2000 https://doi.org/10.1109/59.852100
  15. Y. Qin and S. Du, 'A DSP Based Active Power Filter for Line Interactive UPS,' IEEE IECON Conf. Rec., pp.884-888, 1995
  16. Sergio augusto Oliveira da Silva et al., 'A Comparative Analysis of Control Algorithms for Three Phase Line Interactive UPS Systems with Series Parallel Active Power Line Conditioning Using SRF Method,' IEEE PESC Conf. Rec., vol.2, pp.1023-1028, 2000
  17. A. Nabae I, Takahashi, H. Akagi, 'A New Neutral-Point-Clamped PWM Inverters,' IEEE Trans. on Industry Applications, vol. IA -17, no. 5, pp. 518-523, 1981 https://doi.org/10.1109/TIA.1981.4503992
  18. H. Foch et al., 'Multi-level Conversion; High Voltage Choppers and Voltage-Source Inverters,' IEEE-PESC Conf. Rec., pp. 397-403, 1992
  19. M. Marchesoni, 'High Performance Current Control Techniques for Applications to Multilevel High Power Voltage Source Inverters,' IEEE - PESC Conf. Rec., pp. 672-683, 1989