족저 접촉면의 경도가 경추와 요추의 가동범위에 미치는 영향

The Effect of Cervical & Lumbar Range of Motion According to Plantar Surface Compliance

  • 투고 : 2006.10.22
  • 심사 : 2007.01.20
  • 발행 : 2007.02.01

초록

Purposes : The purpose of this study was to measurement the change of cervical and lumbar range of motion according to plantar surface compliance in standing status. Method : The thirty normal adult(15men and 15women) aged between 20 and 35 were assigned to 3 group: first, in bottom piece shoe plantar form not changed the control group, the fore foot which was hard and the rear foot was soft the FHRS Group, the fore foot which was soft and the rear foot was hard the FSRH Group. The cervical and lumbar Range of motion was examined before and after adaptation with corresponding form types Results : This study investigated the change which appears when it will be soft and hard to be. As a result, FHRS group the cervical extension and lumbar flexion increased and the cervical flexion and lumbar extension decreased(p<0.05). In opposition, the FSRH group the cervical flexion and lumbar extension increased and the cervical extension and lumbar flexion decreased(p<0.05).

키워드