사상체질 진단법의 민감도와 특이도에 관한 연구

The Study on Sensitivity and Specificity of Sasang Constitution Diagnosis Methods

  • 발행 : 2007.12.30

초록

Objectives: We intended to know sensitivity, specificity and relation of diagnosis methods of Sasang Constitution. Methods: We compared QSCC II, PSSC, Body measurement dignosis results with gold standard ones which were diagnosed by Sasang Constitution specialist, and analyzed by crosstables to get the sensitivity and specificity of those. Results and conclusions 1. Sensitivity and specificity of one diagnosis method were low, so call, in QSCC II, Taeumin is 49% in sensitivity, 97% in specificity, Soeumin is 67%, 69%, Soyangin is 59%, 75%, in Body measurement, Taeumin is 66%, 89%, Soeumin is 70%, 82%, Soyangin is 49%, 78%. in PSSC, Taeumin is 57%, 90%, Soeumin is 88%, 62%, Soyangin is 18%, 88%. 2. When two diagnosis methods are consistent each other, sensitivity and specificity are more higher than one diagnosis method. 3. When three diagnosis methods are all consistent, sensitivity and specificity are most highest, but in Soyangin, those are decreased comparing with the case of consistency between QSCC II and Body measurement.

키워드