참고문헌
- Bae SM, Park HS, Kyung HM, Sung JH. Micro-implant anchorage for treatment of skeletal Class I bialveolar protrusion. J Clin Orthod 2001;35;417-22
- Park HS. Clinical study on success rate of microscrew implants for orthodontic anchorage. Korean J Orthod 2003;33: 151-6
- Motoyoshi M, Hirabayashi M, Uemura M, Shimizu N. Recommended placement torque when tightening an orthodontic mini-implant. Clin Oral Implants Res 2006;17: 109-14 https://doi.org/10.1111/j.1600-0501.2005.01211.x
- Quirynen M, Naert I, van Steenberghe D, Nys L. A study of 589 consecutive implants supporting complete fixed prostheses. Part I: periodontal aspects. J Prosthet Dent 1992;68:655-63 https://doi.org/10.1016/0022-3913(92)90383-L
- Degidi M, Piattelli A, Gehrke P, Carinci F. Clinical outcome of 802 immediately loaded 2-stage submerged implants with a new grit-blasted and acid-etched surface: 12-month follow-up. Int J Oral Maxillofac Implants 2006;21:763-8
- Bae SM, Park HS, Kyung HM, Sung JH. Ultimate anchorage control. Tex Dent J 2002;119:580-91
- Bae SM, Kyung HM. Clinical application of micro-implant anchorage (MIA) in orthodontics - anatomic consideration and surgical procedures. The Korean Journal of Clinical Orthodontics 2002;1: 16-29
- Wilmes B, Rademacher C, Olthoff G, Drescher D. Parameters Affecting Primary Stability of Orthodontic Mini-implants. J Orofac Orthop 2006;67:162-74 https://doi.org/10.1007/s00056-006-0611-z
- Akca K, Chang TL, Tekdemir I, Fanuscu MI. Biomechanical aspects of initial intraosseous stability and implant design: a quantitative micro-morphometric analysis. Clin Oral Implants Res 2006;17:465- 72 https://doi.org/10.1111/j.1600-0501.2006.01265.x
- Maniatopoulos C, Pilliar RM, Smith DC. Threaded versus poroussurfaced designs for implant stabilization in bone-endodontic implant model. J Biomed Mater Res 1986;20:1309-33 https://doi.org/10.1002/jbm.820200907
- Szmukler-Moncler S, Salama H, Reingewirtz Y, Dubruille JH. Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature. J Biomed Mater Res 1998;43: 192-203 https://doi.org/10.1002/(SICI)1097-4636(199822)43:2<192::AID-JBM14>3.0.CO;2-K
- Pilliar RM, Lee JM, Maniatopoulos C. Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop Relat Res 1986;208: 108-13
- Soballe K, Hansen ES, B-Rasmussen H, Jorgensen PH, Bunger C. Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. J Orthop Res 1992; 10:285-99 https://doi.org/10.1002/jor.1100100216
- Nkenke E, Hahn M, Weinzierl K, Radespiel-Troger M, Neukam FW, Engelke K. Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants. Clin Oral Implants Res 2003;14:601-9 https://doi.org/10.1034/j.1600-0501.2003.00937.x
- Turkyilmaz I. A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Branemark system implants. J Oral Rehabil 2006;33:754-9 https://doi.org/10.1111/j.1365-2842.2006.01631.x
- Frost HM. Wolffs Law and bone's structural adaptations to mechanical usage: an overview for clinicians. Angle Orthod 1994;64:175-88
- Sugiura T, Horiuchi K, Sugimura M, Tsutsumi S. Evaluation of threshold stress for bone resorption around screws based on in vivo strain measurement of miniplate. J Musculoskel Neuronal Interact 2000;1: 165-70
- Kang ST, Kwon OW, Sung JH, Kyung HM, Park HS. Comparison of histologic observation and insertional and removal torque values between titanium grade 2 and 4 microimplants. Korean J Orthod 2006;36:171-7
- Kim JW, Cho IS, Lee SJ, Kim TW, Chang YI. Effect of dual pitch mini-implant design and diameter of an orthodontic mini-implant on the insertion and removal torque. Korean J Orthod 2006;36:275-83
- Sung JH, Kyung HM, Bae SM, Park HS, Kwon OW, McNamara JA. Microimplants in orthodontics. Dentos, Daegu, Korea. Chap.3:34-6
- Materials Properties Handbook: Titanium Alloys, R. Boyer, G. Welsch, and E. W. Callings, eds. ASM International, Materials Park, OH, USA. 1994
- Kato N, Koshino T, Saito T, Takeuchi R. Estimation of Young's modulus in swine cortical bone using quantitative computed tomography. Bull Hosp Jt Dis 1998;57:183-6
- Tricio J, van Steenberghe D, Rosenberg D, Duchateau L. Implant stability related to insertion torque force and bone density: An in vitro study. J Prosthet Dent 1995;74:608-12 https://doi.org/10.1016/S0022-3913(05)80313-0
- Calandriello R, Tomatis M, Rangert B. Immediate functional loading of Branemark System implants with enhanced initial stability: a prospective 1- to 2-year clinical and radiographic study. Clin Implant Dent Relat Res 2003;5 Suppl 1:10-20 https://doi.org/10.1111/j.1708-8208.2003.tb00011.x
- Lee JH, Chang BS, Lee CK. Evaluation of osseointegration in titanium alloy cortical screws with the passage of time. Journal of the Korean Society Fractures 2004; 17:401-7 https://doi.org/10.12671/jkfs.2004.17.4.401