A Study on the Simulation of Natural Ventilation Effect for Single-sided Casement Window as Opening Types

케이스먼트 창호 개폐방식에 따른 자연환기 효과에 관한 시뮬레이션 연구

  • Published : 2007.08.31

Abstract

At the moment, the reduction of building energy consumption is a unavoidable task of mankind for conserving global environment. Decreasing overall U-value of building envelope and air infiltration, especially in Korean climate condition with clear four seasons, are the obvious solutions for the objective. Thus low glazing ratio with small window openings are required for heating and cooling load reduction in buildings. Using larger window openings could provide better natural ventilation but it also increases the direct solar radiation penetration into indoor space, heat gain in summer and heat loss in winter. On the other hand, the ventilation rates decreasing problem with smaller window openings could be occurred. As a solution for it, the use of casement window can cause increasing natural ventilation rates by wing wall effect. This paper focuses on deduce the most efficient opening type of casement window in Korean climate. To estimate ventilation performance of each opening types, CFD simulation was used. The best performance of opening type in every wind direction is opening both windows to the center and the most appropriate opening type for Korean climate is also opening both windows to center.

Keywords

References

  1. Givoni B., 1962, Basic study of Ventilation Problems in Housing in Hot Countries, Research Report to the Ford Foundation, Isael: Building Research Station, Israel Institute of Technology
  2. Givoni B., 1962, Ventilation Problems in Hot Contries, Research Report to the Ford Foundation, Israel: Building Research Station, Israel Institute of Technology
  3. P.j. Jones, G.E. Whittle, 1992, Computational Fluid Dynamics for Building Air Flow Prediction-current status and capabilities, Building and Environment, Vol. 27, No. 3, pp. 321-338 https://doi.org/10.1016/0360-1323(92)90033-L
  4. J.L. Nju, J.V.D. Kooi, 1992, Two-dimensional Simulation of the Air Flow and Thermal Comfort in a Room with Open-window and cooling systems, Energy and Building, Vol. 18, No. 1, pp. 65-75 https://doi.org/10.1016/0378-7788(92)90053-J
  5. W.K. Chow, 1996, Application of Computational Fluid Dynamics in Building Services engineering, Building and Environment, Vol. 31, pp. 425-436 https://doi.org/10.1016/0360-1323(96)00012-1
  6. Q. Chen, J. Srebric, 2000, Application of CFD Tools for Indoor and Outdoor Environment Design, International Journal on Architectural Science, Vol. 1, pp. 14-29
  7. G. Gan, S.B. Riffat, 1997, Naturally Ventilated Buildings with Heat Recovery: CFD Simulation of Thermal Environment, Building Services Engineering Research Technology, Vol. 18, No. 2, pp. 67-75 https://doi.org/10.1177/014362449701800201
  8. H.B. Awbi, 1989, Application of Computa- tional Fluid dynamics in room ventilation, Building and Environment, Vol. 24, No. 1, pp. 73-84 https://doi.org/10.1016/0360-1323(89)90018-8
  9. S. Murakami, et al., 1999, CFD Analysis of Wind Climate from Human Scale, Journal of Wind Engineering and Industrial Aero- dynamics, Vol. 81, pp. 57-81 https://doi.org/10.1016/S0167-6105(99)00009-4
  10. C.T. Kiranoudis, et al., 2000, Numerical Si- mulation of Air Flow Field in Single- Sided Ventilated Buildings, Energy and Buildings, Vol. 33, No. 1, pp. 41-48 https://doi.org/10.1016/S0378-7788(00)00063-3
  11. C. Alloca, Q. et al., 2002, Design Analysis of Single-sided Natural Ventilation, Energy and Building, Vol. 1534. pp. 1-11
  12. Kim, T. et al., 2005, Study on Indoor Thermal Environment of Office Space Controlled by Cooling Panel System Using Field Measurement and the Numerical Simulation, Building and Environment, Vol. 40, pp. 301-310 https://doi.org/10.1016/j.buildenv.2004.04.010
  13. Lee, J.H., et al., 2005, A Study on the Air Flow Characteristics in an Apartment Complex and Ventilation Performance of an Individual Unit for Improving IAQ, Korea Institute of Ecological Architecture and Environment, Vol. 5, No. 3, pp. 11-15
  14. Kim, T., 2004, Analysis of Contribution Ratio of Pollutant Sources to Indoor Air Quality, Architectural Institute of Korea, Vol. 20, No. 2, pp. 209-216
  15. SAREK Handbook(Fundamentals), 2004, The Society of Air-Conditioning and Refrigerating Engineers of Korea