A Study of Accuracy and Usability for Acupuncture Points Locating Devices

경혈정위 보조도구의 정확성 및 편의성 평가 연구

  • Chae, Youn-Byoung (Acupuncture and Meridian Science Research Center, Kyunghee University, BK21 Oriental Medical Science Center, Kyunghee University) ;
  • Kang, O-Seok (Acupuncture and Meridian Science Research Center, Kyunghee University) ;
  • Hahm, Dae-Hyun (Acupuncture and Meridian Science Research Center, Kyunghee University) ;
  • Lee, Seung-Ho (Acupuncture and Meridian Science Research Center, Kyunghee University) ;
  • Kim, Jai-Soon (School of Physics and Astronomy, Seoul National University) ;
  • Kim, Kwan-Hyung (School of Physics and Astronomy, Seoul National University) ;
  • Kim, Hee-Young (Dept. of Neuroscience and Cell Biology, University of Texas Medical Branch) ;
  • Lee, Hye-Jung (Acupuncture and Meridian Science Research Center, Kyunghee University, BK21 Oriental Medical Science Center, Kyunghee University) ;
  • Park, Hi-Joon (Acupuncture and Meridian Science Research Center, Kyunghee University, BK21 Oriental Medical Science Center, Kyunghee University)
  • 채윤병 (경희대학교 침구경락과학연구센터, 경희대학교 BK21 한의과학사업단) ;
  • 강오석 (경희대학교 침구경락과학연구센터) ;
  • 함대현 (경희대학교 침구경락과학연구센터) ;
  • 이승호 (경희대학교 침구경락과학연구센터) ;
  • 김재순 (서울대학교 물리천문학부) ;
  • 김관형 (서울대학교 물리천문학부) ;
  • 김희영 (미국 텍사스의과대학 신경과학 세포생물학 연구실) ;
  • 이혜정 (경희대학교 침구경락과학연구센터, 경희대학교 BK21 한의과학사업단) ;
  • 박히준 (경희대학교 침구경락과학연구센터, 경희대학교 BK21 한의과학사업단)
  • Published : 2007.06.30

Abstract

Objectives : Accurate and reproducible location of an acupuncture point (AP) have been considered an essential component of meaningful acupuncture research as well as clinical practice. Several kinds of devices have been developed and widely used for the convenience of locating APs. However, the accuracy and convenience of these devices have not been systematically evaluated. The present study was performed to find out the most suitable tools for the location accuracy and location easiness of APs among the devices respectively. Methods : Twenty subjects attempted to locate APs, including PC5 and SP6 in the arm and leg, using four different AP positioning methods: one Conventional Ruler method and three alternative methods including Cunometer, Transparent AP meter, and Elastic Ruler method. The position marked on each AP was plotted onto a thin, flexible, and transparent plastic film, and the dispersion rate of the positions was determined and recorded. The elapsed time for locating each AP was measured. After that each subject was answered to a short questionnaire regarding the degree of convenience and confidence of use of each method for AP location. Results : All of three alternative methods took less time than Conventional Ruler method did. Among these alternative methods, the accuracy of Elastic Ruler method was markedly higher than others. The degree of convenience of the Cunometer and the confidence of Elastic Ruler method were the highest among these alternative methods. Conclusions : The present study indicates that the Elastic Ruler method was the most compatible for the conventional Ruler methods. However, there are many factors need to be reconsidered. Improved devices for locating AP are imperatively needed for clinical practice.