In this research, to establish the emission for the people who are clearing out, through the numerical analysis using the CFD model, the dangerousness has been investigated in the various emission conditions in a station platform. As a result of research, it is found out that the temperature variation falls between 65.37% and 74.97% to compare without installation of platform screen doors. In the addition, with the supply mode or push-pull mode, the warm current is generated in the platform so the temperature and the layer of smoke are stirred up and felled off. It will make the dangerousness when the people escape. Therefore, when the capacity of emission and the space of platform is set up, the design regards the properties of the fire emission.

본 연구에서는 대피자의 최적 배연조건 확립을 위하여 CFD모델을 이용한 수치해석을 통해 지하철 승강장 내에서의 화재 시 다양한 배연조건에서의 화재 위험성을 검토하였다. 결과로 스크린도어를 설치한 경우가 설치하지 않은 경우보다 온도의 상승폭이 최대 $65.37%{\sim}74.97%$ 낮게 나타났다. 또한 급기나 압인배기시 승강장에 난류가 발생함에 따라 온도 및 연기층이 교란되어 하락됨에 따라 탈출시 위험을 유발할 수 있는 것으로 판단되었다. 따라서 배연용량 및 승강장 공간 설정시 배연조건에 따른 화재 특성을 고려한 설계가 필요하다.

Keywords

References

  1. 인천광역시 도시철도건설본부, "인천도시철도 1호선 송도 연장건설사업 기본설계보고서(토목/궤도)"(2004.8)
  2. Kevin McGrattan and Glenn Forney, "Fire Dynamics Simulator(Version 4) User's Guide", NIST(2005. 2)
  3. T.G. Ma and J.G. Quintiere, "Numerical Simulation of Axi-symmetric Fire Plumes: Accuracy and Limitations", Fire Safety Journal, Vol.38, pp.467-492(2003) https://doi.org/10.1016/S0379-7112(02)00082-6
  4. H.R. Baum and B.J. MaCaffery, "Fire Insuced Flow Field-Theory and Experiment", Fire Safety Science Proceedings of the Second International Symposium, pp.129-148(1989)
  5. James A. Milke, "NFPA 92B, Guide For Smoke Management Systems in Malls, Atria, and Large Areas, 2000 Edition", NFPA, pp.47-48(2000)
  6. W.K. Chow, W.Y. Hung, Y. Gao, G. Zou and H. Dong, "Experimental Stusy on Smoke Movement Leading to Glass Damages in Double-skinned Facade", Construction and Building Materials, (2005)
  7. William D. Kennedy, "NFPA 130, Standard for Fixed Guideway Transit and Passenger Rail Systems, 2003 Edition", NFPA(2003)
  8. G.W. Mulholland, "The SFPE Handbook of Fire Protection Engineering, Chapter Smoke Production and Properties", Third Edition, National Fire Protection Association, pp.2-265-266(2002)
  9. John H. Klote and James A. Milke, "Principles of Smoke Managemen", ASHRAE, SFPE(2002)
  10. David A. Purser, "The SFPE Handbook of Fire Protection Engineering, Chapter Toxicity Assessment of Combustion Products", Third Edition, National Fire Protection Association, pp.2-83-171(2002)
  11. D.-H. Rie, M.-W. Hwang, S.-J. Kim, S.-W. Yoon, J.-W. Ko, and H.-Y. Kim, "A Sudy of Optimal Vent Mode for the Smoke Conrtrol of Subway Station Fire", Tunnelling and Underground Space Technology, Vol.21/3-4, pp.302-303(2006) https://doi.org/10.1016/j.tust.2005.12.158
  12. 이동호, 유지오, "지하철 화재시 본선터널 환기시스템에 따른 열 및 연기배출 특성", 한국소방학회논문지, Vol.17, No.2, pp.62-69(2003)