DOI QR코드

DOI QR Code

옥상녹화용 방근층 구성재료의 방근성능에 관한 실험적 연구

Resistance to Root Penetration of Root Barrier for Green Roof System

  • 발행 : 2008.12.20

초록

The purpose of this study is to test performances of 14 types of root barrier materials by applying testing plant: and soils suitable for weather and natural features of Korea. For testing Plants, Plioblastus pygmaed Mitford A and Pyracantha angustifolia have been selected. For testing soil, mixture of pearlite and peat moss in 3:1 ratio Testing container has been fabricated with duplicated structure having inner and outer containers. And the outer container has 2 hinges on its side wall to allow opening and closing. Wet rock wool with 50mm in thickness has been inserted between inner and outer containers to allow root to penetrate through root barrier material and continue to grow. We planted 12 Plioblastus pygmaed Mitford A. and 4 Pyracantha angustifolia per one testing container. Three testing samples have been made for 1 type of root barrier material, which become a total 42 specimens. Planted testing samples have been installed within the greenhouse, which will be observed regularly for 2 years from now on. We started test from July 11, 2008 and had performed intermediate observations every month for initial 3 months. From the 3rd intermediate observation on Sept. 18, we confirmed that 6 types of roe barrier materials have penetrated roots. Even though two types of them have been generally used as root barrier materials for roof planting system, all of three testing samples have a lot of penetrated roots. This result proves that it is not reasonable to introduce testing methods of root barrier from Europe. USA or Japan.

키워드

참고문헌

  1. 권시원 외, 옥상녹화시스템의 방수재료 및 공법개발에 관한 필요성 분석, 한국건축시공학회 논문집 4권 1호, pp.111-18, 2004. 3 https://doi.org/10.5345/JKIC.2004.4.1.111
  2. 오상근 외, 옥상 및 인공지반녹화용 방근재의 성능기준 설정을 위한 방근성 시험방법에 관한 연구, 한국건축시공학회 논문집 7권 1호, pp.79-84, 2007. 3 https://doi.org/10.5345/JKIC.2007.7.1.079
  3. 오상근 외, 옥상녹화에 적용되는 방수층의 내근성능평가 연구, 대한건축학회논문집 구조계, 21권 7호, 2005. 7
  4. 橘大 介 他, 屋上緑化防水システムのための耐根性能の評価 (その1 耐根性能評価試験の考え方), 日本建築学会大会学術 梗概集(近畿), pp.801-802, 2005. 9
  5. 栗原由佳 他, 地下茎の押し付け力の測定, 日本建築学会大会 学術梗概集(関東), pp.861-862, 2006. 9
  6. 石原沙織 他, 防水層耐根性評価のための試験方法の検討, 日本建築学会大会学術梗概集(関東), pp.863-864, 2006. 9
  7. 田中享二 他, クマザサとノシバ根系の侵入隙間, 日本建築 学会大会学術梗概集(関東), pp.865-866, 2006. 9
  8. 澤西良三 他, 屋上緑化防水システムのための耐根性能の評価 (その2 耐根性能評価試験方法), 日本建築学会大会学術梗概 集(近畿), pp.803-804, 2005. 9
  9. 表 淳珠 他, 防水層耐根シートの重ね合わせ部の耐根性, 日本 建築学会大会学術梗概集(九州), pp.919-920, 2007. 9
  10. 後藤良昭, 防水及び耐根保護についての技術, 제1회 한일옥상녹화기술 국제세미나 자료집, 2004. 8
  11. 清水市郎 他, 屋上緑化用防水システムの耐根性能評価方法 の検討(その4 耐根性能評価の経過結果), 日本建築学会大会学術梗概集(関東), pp.857-858, 2006. 9
  12. 永妻勝義, シート防水層の耐根性評価試験, 日本建築学会大会学術梗概集(東海), pp.1269-1270, 1994. 9
  13. 田中享二 他, 防水層耐根性評価のための試験方法の検討, 日本建築学会大会学術梗概集(近畿), pp.799-800, 2005. 9
  14. 表 淳珠 他, 根先の防水層浸入力の測定, 日本建築学会大会学術梗概集(近畿), pp.797-798, 2005. 9
  15. 表 淳珠 他, 地下茎伸長の測定, 日本建築学会大会学術梗概集(関東), pp.859-860, 2006. 9
  16. 清水市郎 他, 屋上緑化防水システムのための耐根性能の評 価(その3 耐根性能評価試験結果), 日本建築学会大会学術 梗概集(近畿), pp.805-806, 2005. 9

피인용 문헌

  1. Greenhouse Test Results for Two Years of Sheet shaped Root Barrier Materials Apply to Green Roof System for Sustainable Building Construction vol.11, pp.6, 2011, https://doi.org/10.5345/JKIBC.2011.11.6.634
  2. A Study on the Joint Property by the Surface Treatment Method on the Jointing Method of PET Film using the High Hardness Liquid vol.18, pp.3, 2014, https://doi.org/10.11112/jksmi.2014.18.3.153