Abstract
The aim of this study was to analyze the aerodynamic properties of the composite cable-stayed bridge by conducting three-dimensional wind tunnel tests. Focusing on the improved section of the bridge in the two-dimensional wind tunnel tests, the bridge's aerodynamic stability was estimated based on the angles of attack and the wind angles. The aerodynamic properties of vertical galloping, torsion galloping,and torsion flutter were also estimated based on the design wind velocity, and because much of the cable-stayed bridge was constructed using FCM, it was not sufficiently stiff during the bridge's construction. Therefore,the experience progressed by stages: from the full stage to the tow stage, and until the bridge became a single tower. Since the original plane was designed to be a steel box girder, the aerodynamic properties of the steel-box-type and composite-type girder could be compared. The results of this study can be utilized as basic data regarding the aerodynamic properties of medium-length and short composite cable-stayed bridges.
본 연구의 목적은 3차원 풍동실험을 이용하여 합성형 사장교의 공기역학적 특성을 분석하는데 있다. 2차원 풍동실험에서 선정된 내풍개선 단면을 가지고 영각, 풍각에 대하여 3차원 모형의 내풍안정성을 평가한다. 설계풍속에서 수직, 비틀림 와류진동, 비틀림 플로터 등의 공기 역학적 특성을 규명하였다. 또한 사장교는 FCM으로 대부분 가설하므로 가설단계에서 강성이 부족하다. 따라서 실험은 완성계, 2개의 가설단계, 독립주탑의 단계별로 나누어 진행되었다. 원설계가 강상형교로 설계되었기 때문에 강상형교와 합성형교의 내풍특성을 비교하였다. 이 논문은 중소형 합성형 사장교의 내풍특성의 기초 자료로 활용될 수 있을 것이다