The primary objective of this research is a study on the pullout bond characteristics of untensioned prestressing strand in concrete. The bond characteristics of untensioned prestressing strand in concrete differs from that of deformed reinforcing bar. In order to use and design untensioned prestressing strand as deformed reinforcing bar, a study for bond characteristics of the untensioned prestressing strand was progressed. Major test variables are embedment length ($10d_b{\sim}60d_b$), concrete cover (45mm, 70mm, 100m) and diameter of strands. (12.7mm : SWPC7, 9.3mm : SWPC7A) As a results, these showed that average bond stress was decreased as a growing the embedment length, and then showed that the bond performance of untensioned prestressing strand was improved if embedment length was above 60$60d_b$.

본 연구는 콘크리트에서 인발실험(pullout test)을 통해서 인장을 가하지 않은 강연선의 부착특성을 파악하기 위한 것이다. 인장을 가하지 않은 강연선의 부착특성은 이형철근이나 인장이 가해진 강연선과는 다르게 나타난다. 본 연구에서 인장을 가하지 않은 강연선을 철근과 같은 용도로 사용하고 설계하기 위해서는 인장을 가하지 않은 강연선의 부착특성에 관한 연구가 필요하다. 본 연구는 묻힘 길이($10d_b{\sim}60d_b$), 콘크리트 피복두께(45mm, 70mm, 100mm), 그리고 강연선의 직경(12.7mm : SWPC7B, 9.3mm : SWPC7A)을 주요변수로 선정하였다. 실험결과, 묻힘길이가 증가함에 따라 상대적으로 평균부착응력은 감소하는 경향을 보여주고 있으며, 묻힘길이가 ($60d_b$) 이상 확보된다면 인장을 가하지 않은 강연선의 부착성능에 기여할 수 있을 거라 판단된다.

Keywords

References

  1. 한국 콘크리트 학회, "콘크리트 구조설계기준", 2002
  2. ACI Committee 318, "Building Code Requirements for Reinforced Concrete (ACI 318-05)," American Concrete Institute, Detroit, 2005
  3. John R. Salmons, Timothy E. McCrate., "Bond Characteristics of Untensioned Prestressing Strand", PCI Journal, Vol.22, No.1, January-February, 1977, pp. 52-65
  4. Panyan., Nipon,J., "Pullout Capacity of Non-Prestressed Bent Strands for Prestressed Concrete Girder", PCI Journal, Vol. 47, No. 4, July-August, 2002, pp. 90-103
  5. Edwards. A. D, Picard, A., "Bonding Properties of 1/2 in. Diameter Strand", ACI Journal, Vol. 69, No. 11, November, 1972, pp. 684-689
  6. Ladson M. Brearley Jr., David W. Johnston., "Pull-out Bond Test of Epoxy-Coated Prestressing Strand", ACI Journal, Vol. 116, No. 8, August, 1990, pp. 2236-2252
  7. Orangun, C. O, Jirsa J. O, Breen, J. E., "A Reevaluation of Test Data on Development Length and Splices", ACI Journal, Proceedings Vol. 74, No. 3, March, 1977, pp. 114-122
  8. Darwin, D., McCabe, S. L., Idun, E. K., and Schoenekase, S. P. "Development Length Criteria : Bars not Confined by Transverse Reinforcement", ACI Structural Journal, Vol. 89, No. 6, Nov-Dec, 1992, pp. 709-720
  9. KS, "Standard specification," Korean Standard Association, Seoul, 2002