Analysis of Series Arc-Fault Signals Using Wavelet Transform

웨이블렛 변환을 이용한 직렬 아크고장 신호 분석

  • Published : 2008.03.01

Abstract

This paper presents the analyzed result of the series arc fault current by using the discrete wavelet transform. The series arcing is caused by a loose connection in series with the load circuit. The series arc current is limited to a moderate value by the resistance of the device connected to the circuit, such as an appliance or a lighting system. The amount of energy in the sparks from the series arcing is less than in the case of parallel arcing but only a few amps are enough to be a fire hazard. Therefore, it is hard to detect the distinctive difference between a normal current and a intermittent arc current. This paper, presents the variation of the ratio of peak values and RMS values of the series arc fault current, and proposes the novel series arc fault detecting method by using the discrete wavelet transform. Loads such as a CFL lamp, a vacuum cleaner, a personal computer, and a television, which has the very similar normal current with the arc current, were selected to confirm the novel method.

Keywords

References

  1. George D. Gregory, Kon Wong, Robert Dvorak, "More about Arc-Fault Circuit Interrupter", IEEE Transactions on Industry Applications, Vol. 40, No. 4, pp. 1006-1011, July/Aug., 2004. https://doi.org/10.1109/TIA.2004.831287
  2. George D. Gregory, Gary W. Scott, "The Arc-Fault Circuit Interrupter, An Emerging Product", Power Systems Technical Conference IEEE, pp. 48-55, May, 1998.
  3. A.F. Sultan, G.W. Swift, D.J. Fedirchuk, "Detecting Arcing Downed-Wires Using Fault Current Flicker And Half-Cycle Asymmetry", IEEE Trans. on Power Delivery, Vol. 9, No. 1, pp. 461-470, Jan. 1994. https://doi.org/10.1109/61.277718
  4. C. Benner, P. Carswell, B.D. Russell, "Improved Algorithm For Detecting Arcing Faults Using Random Faults Behavior", Electric Power System Research, Vol. 17, pp. 49-56, 1989. https://doi.org/10.1016/0378-7796(89)90059-X
  5. S.J. Balser, K.A. Clements, D.J. Lawrence, "A Microprocessor-Based Technique For Detection of High Impedance Faults", IEEE Trans. on Power Delivery , Vol. PWRD-1, No. 3, Jul. 1986.
  6. Power Technologies Inc., "Detection of High Impedance Faults", EPRI Report EL-2413, Jun. 1982.
  7. D.I. Jeerings, J.R. Linders, "Unique Aspects of Distribution System Harmonics Due to High Impedance Ground Faults", IEEE Trans. on Power Delivery, Vol. 5, No. 2, Apr. 1990.
  8. B.D. Russell, R.P. Chinchali, C.J. Kim, "Behavior of Low Frequency Spectra During Arcing Fault And Switching Events", IEEE Trans. on Power Delivery, Vol. 3, No. 4, Oct. 1988.
  9. B.D. Russell, R.P. Chinchali, "A Digital Signal Processing Algorithm For Detecting Arcing Faults on Power Distribution Feeders", IEEE Trans. on Power Delivery, Vol. 4, No. 1, Jan. 1989.
  10. B.M. Aucoin, B.D. Russell, "Distribution High Impedance Fault Detection Utilizing High Frequency Current Components", IEEE Trans. on Power Apparatus and System, Vol. PAS-101, No. 6, Jun. 1982.
  11. K.Y. Lien, S.L. Chen, C.J. Liao, T.Y. Guo, T.M. Lin, and J.S. Shen, "Energy Variance Criterion and Threshold Tuning Scheme For High Impedance Fault Detection", IEEE Trans. on Power Delivery, Vol. 14, No. 3, Jul. 1999.
  12. W.H. Kwon, G.W. Lee, Y.M. Park, M.C. Yoon and M.H. Yoo, "High Impedance Fault Detection Utilizing Incremental Variance of Normalized Even Order Harmonic Power", IEEE Trans. on Power Delivery, Vol. 6, No. 2, Jul. 1991. https://doi.org/10.1109/61.85839
  13. Wen-Jun Li, Yuan-Chun Li, "Arc Fault Detection based on Wavelet Packet", Proceedings of FICML, pp. 18-21, Aug., 2005.
  14. W. Charytoniuk, W. J. Lee, M. S. Chen, J. Cultrera, T. Maffetone, "Arcing Fault Detection in Underground Distribution Networks Feasibility Study", Industry Applications, IEEE Transaction, Vol. 36, No. 6, pp. 1756-1761, Nov., 2000.
  15. A. Lazkano, J. Ruiz, E. Aramendi, L. A. Leturiondo, "Evaluation of A New proposal for Arcing Fault Detection Method Based on Wavelet Packet Analysis", Power Engineering Society Meeting, Vol. 3, pp. 1328-1333, July, 2001.