The mandibular advancement device(MAD) has been used to help manage snoring and obstructive sleep apnea. The aims of this study were to specify the demographic and clinical characteristics of the patients receiving long-term treatment with MAD and to quantify the compliance with and side effects of the use of the device. Of 103 patients who were treated with MAD for at least one full year after delivery date, 49 were able to be contacted with telephone and complete follow-up questionnaires were obtainable. They were telephoned to determine whether they were still using the device. If not, they were asked when and why they stopped using it. Patients were also asked how much effectiveness of the MAD in decreasing snoring and how much they and their bed-partners were satisfied with the MAD therapy. The initial respiratory disturbance indices and pre-treatment snoring frequency and intensity were obtained from the medical records of initial visit. All the data were compared between users and nonusers. The results were as follows: 1. Of 49 patients 25 are still using the device, but 24 stopped using it. Among nonusers nobody stopped wearing the device within first 1 month, but 37.5% of nonusers stopped wearing it in the following 6 months, and another 4.2% before the end of the first year. 2. The one-year compliance of the MAD therapy was 79.59%. 3. There were no significant differences in mean age, mean body mass index, and gender distribution between users group and nonusers group. 4. There was no significant difference in mean respiratory disturbance index at initial visit between users group and nonusers group. 5. There was no significant difference in pre-treatment snoring frequency and intensity between users group and nonusers group. 6. The degree of decrease in snoring with use of MAD was significantly higher in the users when compared to nonusers. 7. Patient's overall satisfaction with treatment outcome was significantly higher in the users when compared to nonusers. 8. Bed partner's satisfaction with treatment outcome tended to be higher in the users when compared to nonusers. 9. The most frequent reasons why patients discontinued wearing the MAD were: jaw pain(25%), dental pain(20.83%), broken appliance(20.83%), hassle using(16.67%), lost weight(8.3%), dental work(8.3%), no or little effect(4.17%), sleep disturbance(4.27).

본 연구의 목적은 하악전방이동장치요법으로 코골이와 수면무호흡증에 대한 치료를 시작한 후 1년이 경과한 한국인 환자들을 대상으로 하악전방이동장치의 지속적 사용 여부, 사용 빈도, 사용 중단 시까지의 사용 기간, 부작용 발생 여부, 그리고 장치사용의 중단 원인 등을 조사하여 하악전방이동장치의 장기적 사용에 영향을 주는 요인을 분석하는 것이다. 경북대학교병원 구강내과에서 코골이와 수면무호흡증을 주소로 내원한 환자들 중에 수면다원검사를 받고 하악전방이동장치요법을 시술받은 후 1년 이상 경과한 환자 103명 중에 전화를 통한 설문조사가 가능했던 49명의 환자를 대상으로 의무기록 조사 및 설문조사를 실하였다. 이들 중 현재까지 장치를 사용하고 있는 환자는 25명이었으며 사용을 중단한 환자는 24명이었다. 이들을 각각 계속사용군과 사용중단군으로 분류하여 두 군 사이에 초진 시의 연령, 성별분포, 체질량지수, 호흡장애지수, 구강장치요법을 시행하기 전의 코골이 빈도와 강도, 구강장치요법 시행 후의 코골이 감소 정도, 본인과 동침자의 구강장치요법에 대한 만족정도 등을 비교하였으며, 사용중단군에 대해서는 중단 사유를 물어봄으로서 다음과 같은 결론을 얻었다. 1. 계속사용군과 사용중단군 사이에 치료 시작 시점의 연령, 성별분포, 체질량지수, 호흡장애지수의 유의한 차이는 없었다. 2. 계속사용군과 사용중단군 사이에 치료 시작 전 코골이 빈도와 강도에서 유의한 차이가 없었다. 3. 계속사용군이 사용중단군에 비해 코골이의 개선정도가 높았다. 4. 계속사용군이 사용중단군에 비해 구강장치요법에 대한 만족도가 높았다. 5. 계속사용군이 사용중단군에 비해 동침자의 구강장치요법에 대한 만족도가 높은 경향을 보였다. 6. 구강장치 사용을 중단하게 된 사유 중에는 턱의 통증(25%), 치아 통증(20%), 장치 파손(20%) 등이 많았으나, 효과가 없어서 사용을 중단한 경우는 4.2%에 불과하였다. 7. 전체 조사대상자의 1년 사용자비율(1년 순응도)은 79.59%로 나타났다.

Keywords

References

  1. Koskenvuo M, Partinen M, Sarna S et al. Snoring as a risk factor for hypertension and angina pectoris. Lancet 1985;20:893-895
  2. Nieto FJ, Young TB, Lind BK et al. Association of sleep-disordered breathing, sleep apnea, and hypertension in a large community-based study. JAMA 2000;283:1829-1836 https://doi.org/10.1001/jama.283.14.1829
  3. Mohsenin V. Sleep-related breathing disorders and risk of stroke. Stroke 2001;32:1271-1278 https://doi.org/10.1161/01.STR.32.6.1271
  4. Martin JM, Carrizo SJ, Vicente E, Agusti AG. Long-term cardiovascular outcomes in men with obstructive sleep apnoea-hypopnoea with or without treatment with continuous positive airway pressure: an observational study. Lancet 2005;365(9464):1046-1053 https://doi.org/10.1016/S0140-6736(05)74229-X
  5. Naegele B, Pepin JL, Levy P, Bonnet C, Pellat J, Feuerstein C. Cognitive executive dysfunction in patients with obstructive sleep apnea syndrome (OSAS) after CPAP treatment. Sleep 1998;21:392-397 https://doi.org/10.1093/sleep/21.4.392
  6. Young T, Blustein J, Finn L, Palta M. Sleepdisordered breathing and motor vehicle accidents in a population-based sample of employed adults. Sleep 1997;20:608-613 https://doi.org/10.1093/sleep/20.8.608
  7. Lugaresi E, Cirignotta F, Montagna P et al. Snoring: pathophysiology and clinical consequences. Semin Respir Med 1988;9:577-585
  8. Suratt PM, Dee P, Atkinson RL, Armstrong P, Wilhol SC. Fluoroscopic and computerized tomographic features of the pharyngeal airway in obstructive sleep apnea. Am Rev Respir Dis 1983;127:487-492 https://doi.org/10.1164/arrd.1983.127.4.487
  9. Haponik EF, Smith PL, Bohlman ME, Allen RP, Goldman SM, Bleeker ER. Computerized tomography in obstructive sleep apnea - correlation of airway size during sleep and wakefulness. Am Rev Respir Dis 1983;127:221-226
  10. Bradley TD, Brown IG, Grossman RF et al. Pharyngeal size in snorers, nonsnorers, and patients with obstructive sleep apnea. N Engl J Med 1986;315:1327-1331 https://doi.org/10.1056/NEJM198611203152105
  11. Brown IB, McClean PA, Boucher R, Zamel N, Hoffstein V. Changes in pharyngeal cross-sectional area with posture and application of continuous positive airway pressure in patients with obstructive sleep apnea. Am Rev Respir Dis 1987; 136:628-632 https://doi.org/10.1164/ajrccm/136.3.628
  12. 최재갑, 정태훈. 하악의 위치 변화가 기도저항에 미치는 영향. 대한구강내과학회지 1998:23;65-73
  13. Ryan CF, Love LL, Fleetham JA, Lowe AA. Mandibular advancement oral appliance therapy for obstructive sleep apnea: effect on awake calibre of the velopharynx. Thorax 1999;54:972-977 https://doi.org/10.1136/thx.54.11.972
  14. Kato J, Isono S, Tanaka A et al. Dose-dependent effects of mandibular advancement on pharyngeal mechanics and nocturnal oxygenation in patients with sleep-disordered breathing. Chest 2000;117:1065-1072 https://doi.org/10.1378/chest.117.4.1065
  15. Ng AT, Gotsopoulos H, Qian J, Cistulli PA. Effects of oral appliance therapy on upper airway collapsibility in obstructive sleep apnea. Am J Respir Crit Care Med 2003;168:238-241 https://doi.org/10.1164/rccm.200211-1275OC
  16. Ng AT, Qian J, Cistulli PA. Oropharyngeal collapse predicts treatment response with oral appliance therapy in obstructive sleep apnea. Sleep 2006;29:666-671
  17. Marklund M, Franklin KA, Sahlin C, Lundgren R. The effect of a mandibular advancement device on apneas and sleep in patients with obstructive sleep apnea. Chest 1998;113:707-713 https://doi.org/10.1378/chest.113.3.707
  18. Lowe AA, Sjoholm TT, Ryan CF, Fleetham JA, Ferguson KA, Remmers JE. Treatment, airway and compliance effects of a titratable oral appliance. Sleep 2000;23:S172-178
  19. Marklund M, Sahlin C, Stenlund H, Persson M, Franklin KA. Mandibular advancement device in patients with obstructive sleep apnea. Chest 2001;120:162-169 https://doi.org/10.1378/chest.120.1.162
  20. Mehta A, Qian J, Petocz P, Darendeliler MA, Cistulli PA. A randomized, controlled study of a mandibular advancement splint for obstructive sleep apnea. Am J Respir Crit Care Med 2001;163:1457-1461 https://doi.org/10.1164/ajrccm.163.6.2004213
  21. Sam K, Lam B, OoiCG, Cooke M, Ip MS. Effect of a non-adjustable oral appliance on upper airway morphology in obstructive sleep apnoea. Respir Med 2006;100:897-902 https://doi.org/10.1016/j.rmed.2005.08.019
  22. Hoffstein V. Review of oral appliances for treatment of sleep-disordered breathing. Sleep Breath 2007;11:1-22 https://doi.org/10.1007/s11325-006-0084-8
  23. Kushida CA, Morgenthaler TI, Littner MR et al. Practice parameters for the treatment of snoring and obstructive sleep apnea with oral appliances: An update for 2005. Sleep 2006;29(2):240-243 https://doi.org/10.1093/sleep/29.2.240
  24. Nakazawa Y, Sakamoto T, Yasutake R et al. Treatment of sleep apnea with prosthetic mandibular advancement. Sleep 1992;15:499-504 https://doi.org/10.1093/sleep/15.6.499
  25. Marklund M, Stenlund H, Franklin KA. Mandibular advancement devices in 630 men and women with obstructive sleep apnea and snoring: tolerability and predictors of treatment success. Chest 2004;125:1270-1278 https://doi.org/10.1378/chest.125.4.1270
  26. McGown AD, Makker HK, Battagel JM, L'Estrange PR, Grant HR, Spiro SG. Long-term use of mandibular advancement splints for snoring and obstructive sleep apnoea: a questionnaire survey. Eur Respir J 2001;17:462-466 https://doi.org/10.1183/09031936.01.17304620
  27. Faber CE, Grymer L, Hjorth T. Anterior mandibular positioning device for treatment of snoring and obstructive sleep apnoea. Rhinology 2003;41:175-181
  28. Dort LC, Hussein J. Snoring and obstructive sleep apnea: compliance with oral appliance therapy. J Otolaryngol 2004;33:172-176 https://doi.org/10.2310/7070.2004.03016
  29. de Almeida FR, Lowe AA, Tsuiki S et al. Long-term compliance and side effects of oral appliances used for the treatment of snoring and obstructive sleep apnea syndrome. J Clin Sleep Med 2005;1:143-152
  30. Pantin CC, Hillman DR, Tennant M. Dental side effects of an oral device to treat snoring and obstructive sleep apnea. Sleep 1999;22:237-240 https://doi.org/10.1093/sleep/22.2.237
  31. Clark GT, Sohn JW, Hong CN. Treating obstructive sleep apnea and snoring: assessment of an anterior mandibular positioning device. J Am Dent Assoc 2000;131:765-771 https://doi.org/10.14219/jada.archive.2000.0275
  32. Walker-Engstrom ML, Wilhelmsson B, Tegelberg A, Dimenas E, Ringqvist I. Quality of life assessment of treatment with dental appliance or UPPP in patients with mild to moderate obstructive sleep apnoea. A prospective randomized 1-year follow-up study. J Sleep Res 2000;9:303-308 https://doi.org/10.1046/j.1365-2869.2000.00210.x
  33. Clark GT, Blumenfeld I, Yoffe N, Peled E, Lavie P. A crossover study comparing the efficacy of continuous positive airway pressure with anterior mandibular positioning devices on patients with obstructive sleep apnea. Chest 1996;109:1477-1483
  34. Ferguson KA, Ono T, Lowe AA, al-Majed S, Love LL, Fleetham JA. A short-term controlled trial of an adjustable oral appliance for the treatment of mild to moderate obstructive sleep apnoea. Thorax 1997;52(4):362-368 https://doi.org/10.1136/thx.52.4.362