Evaluation of Automatic Image Segmentation for 3D Volume Measurement of Liver and Spleen Based on 3D Region-growing Algorithm using Animal Phantom

간과 비장의 체적을 구하기 위한 3차원 영역 확장 기반 자동 영상 분할 알고리즘의 동물팬텀을 이용한 성능검증

  • Kim, Jin-Sung (Proton Therapy Center, National Cancer Center) ;
  • Cho, June-Sik (Department of Radiology, Chungnam University College of Medicine) ;
  • Shin, Kyung-Sook (Department of Radiology, Chungnam University College of Medicine) ;
  • Kim, Jin-Hwan (Department of Radiology, Chungnam University College of Medicine) ;
  • Jeon, Ho-Sang (Nuclear & Quantum Engineering, KAIST) ;
  • Cho, Gyu-Seong (Nuclear & Quantum Engineering, KAIST)
  • 김진성 (국립암센터 양성자치료센터) ;
  • 조준식 (충남대학교 의과대학 영상의학교실) ;
  • 신경숙 (충남대학교 의과대학 영상의학교실) ;
  • 김진환 (충남대학교 의과대학 영상의학교실) ;
  • 전호상 (한국과학기술원 원자력 및 양자공학과) ;
  • 조규성 (한국과학기술원 원자력 및 양자공학과)
  • Published : 2008.09.30

Abstract

Living donor liver transplantation is increasingly performed as an alternative to cadaveric transplantation. Preoperative screening of the donor candidates is very important. The quality, size, and vascular and biliary anatomy of the liver are best assessed with magnetic resonance (MR) imaging or computed tomography (CT). In particular, the volume of the potential graft must be measured to ensure sufficient liver function after surgery. Preoperative liver segmentation has proved useful for measuring the graft volume before living donor liver transplantations in previous studies. In these studies, the liver segments were manually delineated on each image section. The delineated areas were multiplied by the section thickness to obtain volumes and summed to obtain the total volume of the liver segments. This process is tedious and time consuming. To compensate for this problem, automatic segmentation techniques have been proposed with multiplanar CT images. These methods involve the use of sequences of thresholding, morphologic operations (ie, mathematic operations, such as image dilation, erosion, opening, and closing, that are based on shape), and 3D region growing methods. These techniques are complex but require a few computation times. We made a phantom for volume measurement with pig and evaluated actual volume of spleen and liver of phantom. The results represent that our semiautomatic volume measurement algorithm shows a good accuracy and repeatability with actual volume of phantom and possibility for clinical use to assist physician as a measuring tool.

간경변 및간암 환자의 증가로 간이식술의 필요성이 점점 증가되고 있고, 특히 공여자의 생체 간이식은 간이식술의 주된 분야를 차지하고 있으며 간이식 수술 전 공여자에서 간체적의 정확한 측정은 수술 후 공여자와 수여자의 간기능을 예측하는데 있어 중요한 자료가 되며, 성공적인 수술과 환자의 예후에 밀접한 영향을 미친다. 그러나 현재 환자의 간체적을 구하는 과정은 환자의 모든 CT 영상위의 간을 수작업을 통해 영상분할한 후에 3차원 간체적을 구하고 있으며 많은 시간과 노력이 필요한 작업이다. 이러한 문제를 해결하기 위해서 본 논문에서는 자동으로 간과 비장을 문턱값처리, 형태학적 영상처리, 3차원 영역확장법등의 기법을 이용하여 분할하는 알고리즘을 개발하여 체적을 구하는 시간을 단축하였다. 이러한 알고리즘의 정확성을 평가하기 위해서 동물의 실제 간과 비장을 팬텀으로 제작하여 실제 측정한 체적과 알고리즘으로 분할된 영상의 결과를 비교 평가하였다. 문턱치값의 설정에 따라 다른 결과를 보이는 특성이 있지만 자동으로 문턱치를 결정했을 때 비장과 간의 체적측정 오차는 9.27%, -4.52%이었으며, 수동으로 문턱치를 결정했을 때 최소 오차가 각각 0.2%, 0.17%의 결과를 보였다. 이러한 팬텀 연구를 통해 자동 분할 알고리즘으로 얻은 체적의 결과가 정확성과 재현성을 보여주어 추후 간체적을 구하는 보조수단으로 활용될 수 있을 것이라 예상된다.

Keywords