DOI QR코드

DOI QR Code

ANALYSIS OF PRESTRESSED CONCRETE CONTAINMENT VESSEL (PCCV) UNDER SEVERE ACCIDENT LOADING

  • Published : 2008.02.29

Abstract

This paper describes the nonlinear analyses of a 1:4 scale model of a prestressed concrete containment vessel (PCCV) using an axisymmetric model and a three-dimensional model. These two models are refined by comparison of the analysis results and with testing results. This paper is especially focused on the analysis of behavior under pressure and the temperature effects revealed using an axisymmetric model. The temperature-dependent degradation properties of concrete and steel are considered. Both geometric and material nonlinearities, including thermal effects, are also addressed in the analyses. The Menetrey and Willam (1995) concrete constitutive model with non-associated flow potential is adopted for this study. This study includes the results of the predicted thermal and mechanical behaviors of the PCCV subject to high temperature loading and internal pressure at the same time. To find the effect of high temperature accident conditions on the ultimate capacity of the liner plate, reinforcement, prestressing tendon and concrete, two kinds of analyses are performed: one for pressure only and the other for pressure with temperature. The results from the test on pressurization, analysis for pressure only, and analyses considering pressure with temperatures are compared with one another. The analysis results show that the temperature directly affects the behavior of the liner plate, but has little impact on the ultimate pressure capacity of the PCCV.

Keywords

References

  1. Hessheimer, M.F., Klamerus, E.W., Lambert, L.D. and Rightley, G.S., Overpressurization Test of a 1:4-Scale Prestressed Concrete Containment Vessel Model, NUREG/ CR-6810, SAND2003-0840P, Sandia National Laboratories, Albuquerque, March 2003
  2. Smith, S., 'On Fundamental Aspects of Concrete Behavior', MSc Thesis, University of Colorado, 1987
  3. Ph Menetrey and K. J. Willam, 'Triaxial Failure Criter-ion for Concrete and Its Generation', ACI Structural journal, Vol. 92, No. 3, 1995, p.311-318
  4. Wai-Fah Chen, 'Constitutive Equations for Engineering Materials', (Elsevier, 1994)
  5. Hajime Okamura and Kohichi Maekawa, 'Nonlinear Analysis and Constitutive Models of Reinforced Concrete', (Kibodang, 1990)
  6. Hsu, T.T.C., Unified Theory of Reinforced Concrete, CRC Press 1993, 205-218 pp
  7. Khoury, G.A., 'Compressive Strength of Concrete at High Temperatures: a Reassessment,' Magazine of Concrete Research, 44, No. 161, Dec., pp. 291-309, 1992 https://doi.org/10.1680/macr.1992.44.161.291
  8. Abrams, M. S., 'Compressive Strength of Concrete at Temperatures to $1600 ^{\circ}F$,' Temperature and Concrete, ACISP-25, American Concrete Institute, pp. 33-58, 1971
  9. EC2, 'Eurocode 2: Design of Concrete Struc-tures. ENV 1992-1-2: General Rules-Structural Fire Design', European Committee for Standardisation, 1993
  10. Klinski, M., 'Degradation and Plastic Deformation of Concrete', IFTR Report 38, PhD thesis, Polish Academy of Science, 1985
  11. Holmes, M., Anchor, R.D., Cook, M.D. and Crook, R.N., "The Effects of Elevated Temperatures on the Strength Properties of Reinforcing and Prestressing Steels', The Structural Engineer, Vol. 60B, No. 1, March 1982
  12. EC3, 'Eurocode 3: Design of Steel Structures. ENV 1993- 1-2: General Rules-Structural Fire Design', European Committee for Standardisation, 1995
  13. MELCOR Computer Code Manuals, NUREG/CR-6119, SAND2000-2417, Sandia National Laboratories, Albuquerque, NM, December, 2000

Cited by

  1. Mechanical analysis for prestressed concrete containment vessels under loss of coolant accident vol.14, pp.2, 2014, https://doi.org/10.12989/cac.2014.14.2.127
  2. Thermal-pressure loading effect on containment structure vol.50, pp.5, 2014, https://doi.org/10.12989/sem.2014.50.5.617
  3. Ultimate internal pressure of Prestressed Concrete Containment Vessel analyzed by an integral constitutive model vol.21, pp.6, 2017, https://doi.org/10.1007/s12205-016-1027-y
  4. Nuclear Power Plant Prestressed Concrete Containment Vessel Structure Monitoring during Integrated Leakage Rate Testing Using Fiber Bragg Grating Sensors vol.7, pp.4, 2017, https://doi.org/10.3390/app7040419
  5. Mechanical Properties of Prestressed Concrete Members with Inclined Tendon Configuration Subjected to Uniaxial and Biaxial Loading pp.2191-4281, 2018, https://doi.org/10.1007/s13369-018-3318-8