DOI QR코드

DOI QR Code

Delamination Detection at a Bolt Hole Using a Built-in Piezoelectric Active Sensor Array

배열 압전 능동 센서를 이용한 볼트 구멍의 층간분리 탐지

  • 박찬익 (국방과학연구소 제7기술연구본부 2부) ;
  • 김민성 (국방과학연구소 제7기술연구본부 2부)
  • Published : 2008.06.01

Abstract

Delamination damage at a bolt hole in a composite stiffened panel was detected using a built-in piezoelectric active sensor array. Various signal processing techniques were used to detect an invisible small scale delamination around a fastener hole due to localized transverse loading. A built-in piezoelectric sensor array was used to generate diagnostic signals and to measure response signals. Then, the response signals were processed to extract damage-sensitive features. Damage indexes were calculated to estimate the severity and location of the damage from the features.

영구히 장착된 배열 압전 능동 센서를 사용하여 복합재 보강판의 볼트 구멍에 있는 층간분리 손상을 탐지하였다. 다양한 신호처리 기법을 사용하여 국부적인 수직하중에 의하여 발생한 볼트 구멍 주위의 눈에 보이지 않는 작은 층간분리를 탐지하였다. 배열 압전 센서를 사용하여 진단신호를 생성하였으며, 응답신호를 측정하였다. 응답신호를 신호 처리하여 손상에 민감한 특성들을 추출하였다. 이 특성들을 사용하여 손상 지수를 계산하였고, 손상 지수를 사용하여 손상의 유무와 위치를 추정하였다.

Keywords

References

  1. Lichtenwalner, P.E., White, E.V., and Baumann, E.W., "Industrial and Commercial Applications of Smart Structures Technology", Proceedings of 1998 SPIE Conference on Smart Structures and Materials, Vol 3326, 1998, pp. 406-417
  2. Waters, Jr. W.A. and William, J.G., "Failure Mechanism of Laminates Transversely Loaded by Bolt Push-Through", NASA Technical Memorandum 87603, 1985
  3. Banbury, A. and Kelly, D.W., "A Study of Fastener Pull-Through Failure of Composite Laminates. Part 1: Experimental", Composite Structures, Vol. 45, 1999, pp. 241-254 https://doi.org/10.1016/S0263-8223(99)00009-4
  4. Banbury, A., Kelly, D.W., and Jain, L.K. "A Study of Fastener Pull-Through Failure of Composite Laminates. Part 2: Failure Prediction", Composite Structures, Vol. 45, 1999, pp. 255-270 https://doi.org/10.1016/S0263-8223(99)00010-0
  5. Kelly, G. and Hallstrom, S., "Strength and Failure Mechanism of Composite Laminates Subjected to Localised Transverse Loading", Composite Structures, Vol 69, 2005, pp. 301-314 https://doi.org/10.1016/j.compstruct.2004.07.008
  6. http://www.hi-shear.com/standards/hlt310.pdf
  7. Park, C.Y. and Cho, C.-M., "Impact Damage Detection in a Composite Stiffened Panel Using Built-in Piezoelectric Active Sensor Arrays", Journal of Korean Society for Composite Materials, Vol. 20, No. 6, 2007, pp. 21-27
  8. Cao, J.J. and Bell, A.J., "General Solutions for a Circular Flat Plate with a Central Hole Loaded by Transverse Force or Bending Moment uniformly Distributed Along a Circumference", International Journal of Pressure Vessel & Piping, Vol 51, 1992, pp. 155-173 https://doi.org/10.1016/0308-0161(92)90078-T
  9. Robert, M. Jones "Mechanics of Composite Materials", Mcgrow Hill, 1975, pp. 76-80
  10. Ihn, I.-B. and Chang, F.-K., "Detection and Monitoring of Hidden Fatigue Crack Growth Using a Built-in Piezoelectric Sensor/Actuator Network: I. Diagnostics", Smart Materials and Structures, Vol 13, 2004, pp. 609-620 https://doi.org/10.1088/0964-1726/13/3/020