Changes of Lens Morphology and TBUT by Dehydration of Soft Contact Lens

소프트콘택트렌즈 건조로 인한 렌즈 형태 및 TBUT의 변화

  • Park, Mijung (Department of Visual Optics, Seoul National University of Technology) ;
  • Lee, Yu-Na (Department of Visual Optics, Seoul National University of Technology) ;
  • Kang, Kyu Eun (Department of Visual Optics, Seoul National University of Technology) ;
  • Lee, Min Ha (Department of Visual Optics, Seoul National University of Technology)
  • 박미정 (서울산업대학교 안경광학과) ;
  • 이유나 (서울산업대학교 안경광학과) ;
  • 강규은 (서울산업대학교 안경광학과) ;
  • 이민하 (서울산업대학교 안경광학과)
  • Received : 2008.05.02
  • Accepted : 2008.06.10
  • Published : 2008.06.30

Abstract

Purpose: This study was performed to evaluate the changes of lens morphology and tear stability during wearing soft contact lenses (SCLs) which were kept in drying condition like dry eye or became to be dried due to heedless care. Method: SCLs having different water content, thickness or material were rehydrated after being dehydrated artificially 2 or 4 times, and estimated their diameter and radius. Furthermore, the changes of tear film break-up time (TBUT) during SCL wearing were also measured. Result: Due to the dryness, the diameter of both 70% water content SCL and 59% water content SCL decreased, but the decrement was larger in 59% water content SCL. The more 59% water content SCL was dehydrated, the more its radius changed. However, the radius of 70% water content SCL did not change by 2 times dehydration and increased greatly by 4 times dehydration. The reduction of diameter of -1.00 D SCL was greater than that of -9.00 D SCL. Moreover, the radius of -1.00 D SCL increased depending on the frequency of dehydration but that of -9.00 D SCL did not changed. The diameter and radius changes of lotrafilcon B, silicone hydrogel lens, were less than those of hilafilcon B, copolymer of HEMA and N-vinyl pyrrolidone. TBUT during wearing SCLs decreased by wearing dehydrated SCLs. Conclusion: The diameter and radius of dehydrated SCLs as well as TBUT during wearing them were changed in spite of rehydration, which would be the important cause of uncomfortable feeling when people wore dehydrated SCL. The changes of SCL morphology and TBUT differed according to the water content, lens thickness and material.

목적: 본 연구에서는 건안에 착용되어 지속적으로 건조한 상태에 노출되거나 관리 부주의로 건조한 상태가 되었던 소프트콘택트렌즈(soft contact lens, SCL)에 발생되는 렌즈의 형태 및 렌즈 착용시의 누액 안정성에 나타나는 변 화를 알아보고자 하였다. 방법: 함수율과 두께, 재질이 상이한 소프트콘택트렌즈들을 각각 인위적으로 2회 또는 4회 건조시키고 다시 수화시킨 후 렌즈 전체직경 및 곡률반경을 측정하였다. 또한, 소프트콘택트렌즈 착용시의 눈물파 괴시간(tear film break-up time, TBUT)의 변화를 측정하였다. 결과: 건조과정에 의하여 함수율 70% 소프트콘택트 렌즈와 59% 소프트콘택트렌즈 모두에서 전체직경의 감소가 나타났으며, 함수율 59% 소프트콘택트렌즈의 전체직경의 변화 정도가 더 컸다. 함수율 59%의 소프트콘택트렌즈는 건조횟수가 증가함에 따라 곡률반경이 증가하였다. 그러나, 함수율 70%의 소프트콘택트렌즈는 2회 건조시에는 곡률반경에 변화가 없었으며, 4회 건조시에는 곡률반경이 크게 증가하였다. -1.00 D 소프트콘택트렌즈는 -9.00 D 소프트콘택트렌즈 보다 직경의 감소 정도가 더 컸다. 또한, -1.00 D 소프트콘택트렌즈는 건조횟수가 증가하면 곡률반경의 증가정도가 커지는 반면, -9.00 D 소프트콘택트렌즈는 2회 건조시나 4회 건조시에 곡률반경의 차이가 없었다. 실리콘 하이드로겔 렌즈 재질인 lotrafilcon B의 직경 및 곡률반경 변화는 HEMA와 N-vinyl pyrrolidone의 공중합체인 hilafilcon B보다 더 적었다. 렌즈를 착용하였을 때의 TBUT는 건조되었던 소프트콘택트렌즈를 착용시 감소하였다. 결론: 소프트콘택트렌즈가 건조되었을 때 수화 과정을 거치더라도 렌즈의 전체직경 및 곡률반경이 변하였으며, 렌즈 착용시의 TBUT가 감소하였으며, 이러한 변화는 건조 되었던 소프트콘택트렌즈를 착용하였을 때의 착용감 저하의 주요 원인으로 작용할 것이다. 건조로 인한 소프트콘택 트렌즈의 형태 변화 및 TBUT 변화는 함수율, 두께, 재질에 따라 상이하였다.

Keywords