Design and Implementation of a Digital Control Unit for an Oxygenaire Servo Baby Incubator

  • Published : 2008.04.30

Abstract

This paper introduces a design and implementation of a digital control unit for an Oxygenaire Servo Baby Incubator. The control unit is designed and implemented according to international standards. The control unit is based on an AVR Atmel microcontroller unit. It is built for monitoring and control and displays the three main temperature values: set point temperature, baby skin temperature and air temperature. User friendly software is implemented. The implemented control unit was tested in the laboratory as well as in the field. The control unit is sensitive to change of $0.1^{\circ}C$. At startup, based on a unique control strategy, the incubator reaches its steady state in about 14 minutes. The system schematic diagrams are shown in the paper. Also, programs flow charts are presented. The control unit was designed and implemented based on a contract between the Electronics Research Institute (ERI) and ENGIMED Company. The authors would like to thank ERI and ENGIMED for introducing all required finance and shoring to complete this work.

Keywords

References

  1. N. Rutter, M.D., M.R.C.P., "A Guide to Incubator Care of Infants", Vickers Medical Ltd (1995)
  2. M.H. Rashid, "Power Electronics Handbook", Academic Press, San Diego, California, 2001
  3. Douglas V. Hall "Microprocessors and Interfacing programming and hardware", McGraw-hill Inc., 1992
  4. D4 Surgicals (INDIA) PVT. LTM., "Infant Incubator", http://www.d4 medical-surgicalequipments.com /medical-surgical-equipments.html# infant-incubator
  5. COBAMS SRL, "Neonatal incubators", Via Cicogna 20, San Lazzaro Di Savena, Bologna Italy, Italy, http://www.alibaba.com/company/10681037.html#companyprofile
  6. Sandra Lee Smith, "Heart Period Variability of Intubated Very-Low-Birth-Weight Infants during Incubator Care and Material Holding", AMERICAN JOURNAL OF CRITICAL CARE, Vol. 12, No.1, Jan. 2003
  7. Michael P. Meyer, Matthew J. Payton, Andrew Salmon, Chris Hutchinson and Alan de Klerk, "A Clinical Comparison of Radiant Warmer and Incubator Care for Preterm Infants From Birth to 1800 Grams", http://www.pediatrics.org/cgi/content/full/108/2/395
  8. SAUDI Standard Organization, "Medical Electrical Equipment Part 2: Particular Requirements for Safety of Baby Incubators"
  9. D. A. Ducker and N. Marshall, " Humidification without risk of infection in the Dräger Incubator 8000", http://www.draeger.com/MT/internet/pdf/CareAreas/PerinatalCare/pc_incu 8000_humidity_book_en.pdf
  10. Hannah Lieberman, "Incubator Baby Shows: A Medical and Social Frontier", http://www.historycooperative.org/journals / ht/35.1/lieberman.html, Vol. 35, Issue 1, June 2006
  11. Maciej K. Ginalski, Andrzej J. Nowak, Luiz C. Wrobel, "A combined study of heat and mass transfer in an infant incubator with an overhead screen", http://bura.brunel.ac.uk/bitstream/2438/1701/1/Medical Enginering &Physics.pdf