Abstract

In the bi-directional pile load test (BD PLT) for pile load tests of Mega pile foundations, loading capacity standard is not specified exactly. Therefore there are so many confusions in performing the BD PLT and variations up to maximum 2 times in loading capacity are come out. In this study, standards of bi-directional pile load test (BD PLT) were considered. Based on cases of the bi-directional pile load test performed in domestic areas, maximum equivalent test load, test load increasing ratio, loading capacity increasing ratio and sufficiency ratio of design load were analyzed. It could be known that the loading capacity standard of bi-directional pile load test must be defined as 1-directional loading capacity and also must be established as more than 2 times of design load.

대형말뚝기초의 양방향 재하시험에서 재하용량 기준이 정확하게 규정되어 있지 않다. 그래서 양방향말뚝재하시험을 수행함에 있어 많은 혼란이 발생하고 있으며 재하용량에서 최대 2배까지의 차이가 나타나고 있다. 본 연구에서는 양방향 말뚝재하시험 기준들을 고찰하였으며, 국내에서 수행된 양방향 말뚝재하시험 사례들에 기초하여 최대등가시험하중, 재하하중 증가비, 재하용량 증가비 및 설계하중 충족비를 분석하였다. 양방향 말뚝재하시험 기준은 1방향 재하용량으로 정의되어야 하며, 1방향 재하용량은 설계하중의 2배 이상 이어야 한다는 것을 알 수 있었다.

Keywords

References

  1. 대한건축학회(2005) 건축기초구조설계기준.
  2. (사)한국지반공학회(2003) 구조물 기초설계기준 해설, 건설교통부제정.
  3. 한국지반공학회 기초기술위원회 & 국제지반공학회 ATC-18(2007a) 기초의 재하시험 기준 및 해설, 한국지반공학회기초기술위원회 & 국제지반공학회 ATC-18 (2007) 활동사례집 1.
  4. 한국지반공학회 기초기술위원회 & 국제지반공학회 ATC-18(2007b) 일본지반공학회기준 말뚝의 연직재하시험방법 및 해설 - 제1회개정판, 일본지반공학회 편, 한국지반공학회 기초기술위원회 & 국제지반공학회 ATC-18 (2007) 활동사례집 2.
  5. (社)地盤工學會(2002) 抗の沿直裁何試驗方法同解說-第1會改正版.