An Experimental Study for the Effect of Ventilation Velocity on Performance of a High Pressure Water Mist Fire Suppression System

객차내 환기속도가 고압 미세물분무 화재제어 시스템 성능에 미치는 영향에 대한 실험적 연구

  • Kim, Dong-Woon (Department of Mechanical Engineering, Chung-Ang University) ;
  • Bae, Seung-Yong (Department of Mechanical Engineering, Chung-Ang University) ;
  • Ryou, Hong-Sun (Department of Mechanical Engineering, Chung-Ang University)
  • Published : 2008.08.31

Abstract

This experiments are perfol1ned to investigate the effect of ventilation velocity on a high pressure water mist tire suppression in train. The experiment is conducted in half scale modeled train of a steel-welled enclosure (5.0m${\times}$2.4m${\times}$2.2m). The ventilation velocity is controlled by the ventilation duct through an inverter in the range of 0 to 3m/s. The coverage-radius and an injection angle of an high pressure water mist system are measured. The mist nozzle with 5-injection holes is operated with pressure 60bar. The heptane pool fires are used. The fire extinguishment times and the temperature are measured for the ventilation velocities. In conclusion, because the momentum of injected water mist is more dominant than that of ventilation air, the characteristics of water mist, the fire extinguishment times and the temperature are affected very little by ventilation velocity.

Keywords

References

  1. B. Yao, W. Fan and G. Liao, "Interaction of Water Mists with a Diffusion Flame in a Confined Space", Fire Safety Journal, Vol. 33, pp. 129-139, 1999 https://doi.org/10.1016/S0379-7112(99)00020-X
  2. M. Morita, T. Minami, A. Kikkawa, A. Kubota, H. Megumi and H. Suzuki, "Suppression Mechanism of Water Mist for Pool Fire", 15th Meeting of the UJNR Panel on Fire Research and Safety, Vol. 1, pp. 273- 279, 2000
  3. H. Barrow and C.W. Pope, "Droplet Evaporation with Reference to the Effectiveness of Water Mist Cooling", Applied Energy, Vol. 84, pp. 404-412, 2007 https://doi.org/10.1016/j.apenergy.2006.09.007
  4. J. Liu, J. Qin, X. Huang and G. Liao, "Experimental Study on Suppressing PVC Fire with Water Mist in a Confined Space", Polymer Degradation and Stability, Vol. 92, pp. 747-751, 2007 https://doi.org/10.1016/j.polymdegradstab.2007.02.010
  5. K.C. Adiga, R. F. H. Jr, R. S. Sheinson, F. W. Williams and S. Ayers, "A Computational and Experimental Study of Ultra Fine Water Mist as a Total Flooding Agent", Fire Safety Journal, Vol. 42, pp. 150-160, 2007 https://doi.org/10.1016/j.firesaf.2006.08.010
  6. 김성찬, 박현태, 유홍선, "물분무를 이용한 화재 제어에 관한 실험적 연구", 대한기계학회 논문집 B권, 제27권, 제3호, pp. 367-373, 2003
  7. 노재성, 양승신, 유홍선, 김동현, 정우성, 장용준, "중저압 물분무를 이용한 객차내 화재 진압에 관한 실험 및 수치해석적 연구", 한국철도학회지, 제9권, 제3호, pp. 291-297, 2006
  8. 고승우, 노경철, 유홍선, "지하철 객차내 공조시스템이 미세물분무 시스템에 미치는 영향에 대한 수치해석", 한국안전학회 추계학술발표회 논문집, pp. 24-28, 2006
  9. J. G. Quintiere, "Principles of Fire Behavior", Book, pp. 109-111, 1998
  10. 고승우, 고권현, 유홍선, "액적분열을 고려한 미세물분무 화재제어에 대한 수치해석", 한국철도학회논문집, 제9권, 제3호, pp. 291-297, 2006
  11. 철도화재 조기탐지/자동소화 장치개발 연구보고서, R&D/03-안전22, pp. 345-364, 2007