DOI QR코드

DOI QR Code

Advanced Flow Visualization Techniques for Diagnosing Microscale Biofluid Flows

미세 생체유동 해석을 위한 첨단 유동가시화기법

  • 이상준 (포항공과대학교 기계공학과)
  • Published : 2009.01.01

Abstract

Recently microscale biofluid flows have been receiving large attention in various research areas. However, most conventional imaging techniques are unsatisfactory due to difficulties encountered in the visualization of microscale biological flows. Recent advances in optics and digital image processing techniques have made it possible to develop several advanced micro-PIV/PTV techniques. They can be used to get quantitative velocity field information of various biofluid flows from visualized images of tracer particles. In this paper, as new advanced micro-PIV techniques suitable for biofluid flow analysis, the basic principle and typical applications of the time-resolved micro-PIV and X-ray micro-PIV methods are explained. As a 3D velocity field measurement technique for measuring microscale flows, holographic micro-PTV method is introduced. These advanced PIV/PTV techniques can be used to reveal the basic physics of various microscale biological flows and will play an important role in visualizing veiled biofluid flow phenomena, for which conventional methods have many difficulties to analyze.

Keywords

References

  1. Gravesen, P., Branebjerg, J. and Jensen, O. S., 1993, “Microfluidics-a Review,” Journal of Micromechanics and Microengineering, Vol. 3, pp. 168-182 https://doi.org/10.1088/0960-1317/3/4/002
  2. Stone, H. A., Stroock, A. D. and Ajdari, A., 2004, “Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip,” Annual Review of Fluid Mechanics, Vol. 36, pp. 381-411 https://doi.org/10.1146/annurev.fluid.36.050802.122124
  3. Adrian, R.J., 1991, “Particle Imaging Techniques for Experimental Fluid Mechanics,” Annual Review of Fluid Mechanics, Vol. 23, pp. 261-304 https://doi.org/10.1146/annurev.fl.23.010191.001401
  4. Kim, H. B. and Yu, C. H., 2008, “Stereoscopic Micro-PTV Measurement of Micro Impinging Jet Flow,” 13th International Symposium on Flow Visualization, Proc 386., Nice, France
  5. Meng, H. and Hussain, F., 1995, “In-Line Recording and Off-Axis Viewing Technique for Holographic Particle Velocimetry,” Applied Optics, Vol. 34, pp. 1827-1840 https://doi.org/10.1364/AO.34.001827
  6. Sheng, J., Malkiel, E. and Katz, J., 2003, “Single Beam Two-Views Holographic Particle Image Velocimetry,” Applied Optics, Vol. 42, pp. 235-250 https://doi.org/10.1364/AO.42.000235
  7. Santiago, J. G., Wereley, S. T., Meinhart, C. D., Beebe, D. J. and Adrian, R. J., 1998, “A Particle Image Velocimetry System for Microfluidics,” Experiments in Fluids, Vol. 25, pp. 316-319 https://doi.org/10.1007/s003480050235
  8. Meinhart, C. D., Wereley, S. T. and Santiago, J. G., 1999, “PIV Measurements of a Microchannel Flow,” Experiments in Fluids, Vol. 27, pp. 414-419 https://doi.org/10.1007/s003480050366
  9. Meinhart, C. D., Wereley, S. T. and Gray, M. H. B., 2000, “Volume Illumination for Two-Dimensional Particle Image Velocimetry,” Measurement Science and Technology, Vol. 11, pp. 809-814 https://doi.org/10.1088/0957-0233/11/6/326
  10. Meinhart, C. D. and Zhang, H., 2000, “The Flow Structure Inside a Microfabricated Inkjet Printhead,” Journal of Microelectromechanical Systems, Vol. 9, pp. 67-75 https://doi.org/10.1109/84.825779
  11. Olsen, M. G. and Adrian, R. J., 2000, “Out-of-Focus Effects on Particle Image Visibility and Correlation in Microscopic Particle Image Velocimetry,” Experiments in Fluids, Vol. 7, pp. S166-S174 https://doi.org/10.1007/s003480070018
  12. Olsen, M. G. and Adrian, R. J., 2000, “Brownian Motion and Correlation in Particle Image Velocimetry,” Optics Laser Technology, Vol. 32, pp. 621-627 https://doi.org/10.1016/S0030-3992(00)00119-5
  13. Wereley, S. T., Gui, L. and Meinhart, C. D., 2002, “Advanced Algorithms for Microscale Particle Image Velocimetry,” AIAA J., Vol. 40, pp. 1047-1055 https://doi.org/10.2514/2.1786
  14. Olsen, M. G. and Bourdon, C. J., 2003, “Out-of-Plane Motion Effects in Microscopic Particle Image Velocimetry,” Journal of Fluids Engineering, Vol. 125, pp. 895-901 https://doi.org/10.1115/1.1598989
  15. Meinhart, C. D. and Wereley, S. T., 2003, “The Theory of Diffraction-Limited Resolution in Microparticle Image Velocimetry,” Measurement Science and Technology, Vol. 14, pp. 1047-1053 https://doi.org/10.1088/0957-0233/14/7/320
  16. Manjunatha, M. and Singh, M., 2002, “Digital Blood Flow Analysis from Microscopic Images of Mesenteric Microvessel with Multiple Branching,” Clinical Hemorheology and Microcirculation, Vol. 27, pp. 91-106
  17. Nakano, A., Minamiyama, M., Sugii, Y. and Nishio, S., 2001, “Measurement of Red Blood Cell Velocity Profile in Microvessels Using Particle Image Velocimetry Combined with High-Speed Digital Camera,” Microcirculation Annuals, Vol. 17, pp. 159-160 https://doi.org/10.1159/000179224
  18. Nakano, A., Sugii, Y., Minamiyama, M. and Niimi, H., 2003, “Measurement of Red Cell Velocity in Microvessels Using Particle Image Velocimetry (PIV),” Clinical Hemorheology and Microcirculation, Vol. 29, pp. 445-455
  19. Sugii, Y., Nishio, S. and Okamoto, K., 2002, “In vivo PIV Measurements of Red Blood Cell Velocity Field in Microvessels Considering Mesentery Motion,” Physiological Measurement, Vol. 23, pp. 403-416 https://doi.org/10.1088/0967-3334/23/2/315
  20. Lee, S.J., 2003, “Micro-PIV Technique for Analyzing Flow Inside a Microchannel,” KSME Journal, Vol. 43(2), pp.32-37
  21. Lee, S.J. and Kim, G. B., 2003, “Analysis of Flow Resistance Inside Microchannels with Different Inlet Configuration Using Micro-PIV System,” 1st International Conference on Microchannels and Minichannels, pp. 823-828, Rochester, USA
  22. Sugii, Y., Nishio, S., Okuno, T. and Okamoto, K., 2000, “A Highly Accurate Iterative PIV Technique Using a Gradient Method,” Measurement Science and Technology, Vol. 11, pp. 1666-1673 https://doi.org/10.1088/0957-0233/11/12/303
  23. Lee, J. Y., Ji, H. S. and Lee, S. J., 2007, “Micro-PIV Measurements of Blood Flow in Extraembryonic Blood Vessels of Chicken Embryos,” Physiological Measurement, Vol. 28, pp. 1149-1162 https://doi.org/10.1088/0967-3334/28/10/002
  24. Kim, B.H., Lee, J.Y. and Lee, S.J., 2008, "Experimental Research on Blood Sucking Phenomena of a Female Mosquito," 7th JSME-KSME Thermal & Fluids Engineering Conference, paper J141, Sapporo, Japan
  25. Lee, S. J. and Kim, G. B., 2003, “X-Ray Particle Image Velocimetry for Measuring Quantitative Flow Information Inside Opaque Objects,” Journal of Applied Physics, Vol. 94, pp. 3620-3623 https://doi.org/10.1063/1.1599981
  26. Lee, S. J. and Kim, G. B., 2005, “Synchrotron Micro-Imaging Technique for Measuring the Velocity Field of Real Blood Flows,” Journal of Applied Physics, Vol. 97, pp. 064701 https://doi.org/10.1063/1.1851596
  27. Lee, S.J. and Kim, S., 2005, “Simultaneous Measurement of Size and Velocity of Microbubbles Moving in an Opaque Tube Using an x-Ray Particle Tracing Velocimetry Technique,” Experiments in Fluids, Vol. 39, pp.492-497 https://doi.org/10.1007/s00348-005-0956-x
  28. Lee, S.J. and Kim, Y.M., 2008, “In vivo Visualization of the Water Refilling Process in Xylem Vessels Using x-ray Micro-Imaging,” Annals of Botany, Vol. 101(4), pp.595-602 https://doi.org/10.1093/aob/mcm312
  29. Yoon, S. Y. and Kim, K. C., 2006, “3D particle position and 3D velocity field measurement in a microvolume via the defocusing concept,” Measurement Science and Technology, Vol. 17, pp. 2897-2905 https://doi.org/10.1088/0957-0233/17/11/006
  30. Meng, H., Pan, G., Pu, Y. and Woodward, S. H., 2004, “Holographic Particle Image Velocimetry: from Film to Digital Recording,” Measurement Science and Technology, Vol. 15, pp. 673-685 https://doi.org/10.1088/0957-0233/15/4/009
  31. Pan, G. and Meng, H., 2003, “Digital Holography of Particle Fields: Reconstruction by Use of Complex Amplitude,” Applied Optics, Vol. 42, pp. 827-833 https://doi.org/10.1364/AO.42.000827
  32. Sheng, J., Malkiel, E. and Katz, J., 2006, “Digital Holographic Microscope for Measuring Three-Dimensional Particle Distributions and Motions,” Applied Optics, Vol. 45, pp. 3893-3901 https://doi.org/10.1364/AO.45.003893
  33. Kim, S. and Lee, S. J., 2007, “Measurement of 3D Laminar Flow Inside a Micro-Tube Using Micro Digital Holographic Particle Tracking Velocimetry,” Journal of Micromechanics and Microengineering, Vol. 17, pp. 2157-2162 https://doi.org/10.1088/0960-1317/17/10/030
  34. Kim, S.J. and Lee, S.J., 2008, “Effect of Particle Number Density in in-Line Digital Holographic Particle Velocimetry,” Experiments in Fluids, Vol. 44, pp.623-631 https://doi.org/10.1007/s00348-007-0422-z
  35. Schnars, U. and Juptner, W., Digital Holography, Springer, 2005