Enzyme-Conjugated CdSe/ZnS Quantum Dot Biosensors for Glucose Detection

  • Kim, Gang-Il (Department of Materials Science and Engineering, Korea University) ;
  • Sung, Yun-Mo (Department of Materials Science and Engineering, Korea University)
  • Published : 2009.01.31

Abstract

Conjugated nanocrystals using CdSe/ZnS core/shell nanocrystal quantum dots modified by organic linkers and glucose oxidase (GOx) were prepared for use as biosensors. The trioctylphophine oxide (TOPO)-capped QDs were first modified to give them water-solubility by terminal carboxyl groups that were bonded to the amino groups of GOx through an EDC/NHS coupling reaction. As the glucose concentration increased, the photoluminescence intensity was enhanced linearly due to the electron transfer during the enzymatic reaction. The UV-visible spectra of the as-prepared QDs are identical to that of QDs-MAA. This shows that these QDs do not become agglomerated during ligand exchanges. A photoluminescence (PL) spectroscopic study showed that the PL intensity of the QDs-GOx bioconjugates was increased in the presence of glucose. These glucose sensors showed linearity up to approximately 15 mM and became gradually saturated above 15 mM because the excess glucose did not affect the enzymatic oxidation reaction past that amount. These biosensors show highly sensitive variation in terms of their photoluminescence depending on the glucose concentration.

Keywords

References

  1. M. G. Bawendi, M. L. Steigerwald and L. E. Brus, Annu. Rev. Phys. Chem., 41, 477 (1990) https://doi.org/10.1146/annurev.pc.41.100190.002401
  2. A. P. Alivisatos, Science, 271, 933 (1996) https://doi.org/10.1126/science.271.5251.933
  3. C. B. Murray, D. J. Norris and M. G. Bawendi, J. Am. Chem. Soc., 115, 8706 (1993) https://doi.org/10.1021/ja00072a025
  4. Y.-M. Sung, Y.-J Lee and K.-S.Park, J. Am. Chem. Soc., 128, 9002 (2006) https://doi.org/10.1021/ja061858c
  5. B. O. Dabbousi, J. Rodriquez-Viejo, F. V. Mikulec, J. R. Heine, H. Mattoussi, R. Ober, K. F. Jensen and M. G. Bawendi, J. Phys. Chem. B., 101, 9463 (1997) https://doi.org/10.1021/jp971091y
  6. M. Bruchez Jr., M. Moronne, P. Gin, S.Weiss and A. P. Alivisatos, Science, 281, 2013 (1998) https://doi.org/10.1126/science.281.5385.2013
  7. A. P. Alivisatos, Nature Biotechnol., 22, 47 (2004) https://doi.org/10.1038/nbt927
  8. X. Michalet, F. F. Pinaud, L. A. Bentolila, J. M. Tsay, S. Doose, J. J. Li, G. Sundaresan, A. M.Wu, S. S. Gambhir and S.Weiss, Science, 307, 538 (2005) https://doi.org/10.1126/science.1104274
  9. H. Liu and N. Hu, Electroanal., 19, 884 (2007) https://doi.org/10.1002/elan.200603792
  10. C.-P. Huang, Y.-K. Ki and T.-M. Chen, Biosens. Bioelectron., 22, 1835 (2007) https://doi.org/10.1016/j.bios.2006.09.003
  11. S. Zhang, N. Wang, H. Yu, Y. Niu and C. Sun, Bioelectrochem., 67, 15 (2005) https://doi.org/10.1016/j.bioelechem.2004.12.002
  12. Y.-M. Sung, K.-S. Park, Y.-J. Lee, W.-S. Chae and Y.-W. Song, Electrochem. Solid-State Lett., 8, H24 (2005) https://doi.org/10.1149/1.1850398
  13. H. F. Arata, P. Low, K. Ishizuka, C. Bergaud, B. Kima, H. Noji and H.Fujita, Sens. Actuator B-Chem., 117, 339 (2006) https://doi.org/10.1016/j.snb.2005.11.017
  14. K. E. Sapsford, T. Pons, I. L. Medintz and H. Mattoussi, Sensors, 6, 925 (2006) https://doi.org/10.3390/s6080925
  15. D. B. Cordes, S. Gamsey, B. Singaram, Angew. Chem. Int. Ed., 45, 3829 (2006) https://doi.org/10.1002/anie.200504390
  16. I. Yildiz, M. Tomasulo and F. M. Raymo, Proc. Natl. Acad. Sci. USA, 103, 11457 (2006) https://doi.org/10.1073/pnas.0602384103
  17. W. C. W. Chan and S. Nie, Science, 281, 2016 (1998) https://doi.org/10.1126/science.281.5385.2016
  18. Z. A. Peng and X.Peng, J. Am. Chem. Soc., 123, 183 (2001) https://doi.org/10.1021/ja003633m
  19. Y.-J. Lee, T. G. Kim and Y.-M. Sung, Nanotechnol., 17, 3539 (2006) https://doi.org/10.1088/0957-4484/17/14/030
  20. N. Patel, M. C. Davies, M. Harshorne, R. Heaton, C. J. Roberts, S. J. B. Tendler and P. M. Williams, Langmuir, 13, 6485 (1997) https://doi.org/10.1021/la970933h
  21. J. C. Pickup, F. Hussain, N. D. Evans, O. J. Rolinski and D. J. S.Birch, Biosens. Bioelectron., 20, 2555 (2005) https://doi.org/10.1016/j.bios.2004.10.002
  22. H.Xie, X. L. Tan and Z. Gao, Front. Biosci., 10, 1797 (2005) https://doi.org/10.2741/1662

Cited by

  1. Glucose Sensing by Fluorescent Nanomaterials pp.1547-6510, 2019, https://doi.org/10.1080/10408347.2019.1565984