A Study on Power Factor Control of Inverter-based DG System with Considering the Capacity of an Active Harmonic Filter and an Inverter

고조파 필터 및 인버터의 용량을 고려한 분산전원 시스템의 역률 제어에 관한 연구

  • 김영진 (서울대 공대 전기.컴퓨터공학부) ;
  • 황평익 (서울대 공대 전기.컴퓨터공학부) ;
  • 문승일 (서울대 공대 전기.컴퓨터공학부)
  • Published : 2009.11.01

Abstract

Electric power quality in power transmission/distribution systems has considerably been deteriorated with the increase in the capacity of distributed generators (DGs). It is because inverters, connecting DGs to conventional power grids, tend to generate harmonic current and voltage. For harmonic mitigation, a large amount of research has been done on passive and active filters, which have been operating successfully in many countries. This paper, therefore, presents how to adopt the filters to an inverter-based DG, with considering a system consisting of both inverter-based DG and harmonic filters. In particular, this paper describes the simulation results using the PSCAD/EMTDC: firstly, the relationship between total harmonic distortion(THD) of current and output power of DG: secondly, the harmonic mitigation ability of passive and active filters. The system, furthermore, is obliged to satisfy the regulations made by Korean Electric Power Corporation(KEPCO). In the regulations, power factor should be maintained between 0.9 and 1 in a grid-connected mode. Thus, this paper suggests two methods for the system to control its power factor. First, the inverter of DG should control power factor rather than an active filter because it brings dramatic decrease in the capacity of the active filter. Second, DG should absorb reactive power only in the range of low output power in order to prevent useless capacity increase of the inverter. This method is expected to result in the variable power factor of the system according to its output power.

Keywords

References

  1. Joel Makower, Ron Pernick, 'Clean Energy Trends 2008', Clean Edge, 2008
  2. J. Thongpron, et al., 'Study of a PV - Grid Connected System on its Output Harmonics and Voltage Variation', Asian J. Energy Environ., Vol. 5, pp. 59-73, 2004
  3. M. Sidrach-de-Cardona, J. Carretero, 'Analysis of the current total harmonic distortion for different single-phase inverters for grid-connected pv-systems', Solar Energy Materials & Solar Cells, Vol. 87, pp. 529-540, May 2005 https://doi.org/10.1016/j.solmat.2004.08.016
  4. Alex Domijan, Jr., E. Embriz-Santander, 'Harmonic Mitigation Techniques for The Improvement of Power Quality of Adjustable Speed Drives(ASDs)', Applied Power Electronics Conference and Exposition, 1990. APEC '90, Conference Proceedings 1990., Fifth Annual, pp. 96-105, March 1990
  5. Bhim Sing h, G. Bhuvaneswari, Vipin Grag, 'Harmonic Mitigation Using 12-Pulse AC-DC Converter in Vector-Controlled Induction Motor Drives', IEEE Transactions on power delivery, Vol. 21, pp. 1483-1492, July 2006 https://doi.org/10.1109/TPWRD.2005.860265
  6. 이동원, 여상민, 김철환, '배전 계통에서 단상 컨버터에 의한 고조파 영향 분석 및 저감 대책에 관한 연구', 2009 대한전기학회 전력기술부문회 전력계통연구회 춘계학술대회 논문집, pp. 76-78, 2009
  7. 한국전력공사 배전처 '분산형 전원 배전계통 연계 기술기준', 2005
  8. C. Schauder, H. Mehta, 'Vector analysis and control of advanced static VAR compensators', IEE PROCEEDINGS-C, Vol. 140, pp. 299-306, July 1993
  9. Z. Lubosny, Wind Turbine Operation in Electric Power Systems: Advanced Modeling, Springer, Jan. 2003
  10. Jos Arrillaga, Neville R. Watson, Power System Harmonics, Wiley, Dec. 2003
  11. 김영진, 황평익, 문승일, '능동 필터와 수동 필터를 이용한 태양광발전의 고조파 저감 기법의 비교', 2009 대한전기학회 전력기술부문회 전력계통연구회 춘계학술대회 논문집, pp. 64-66, 2009
  12. Jayanti Navilgone Ganesh, 'Unified power quality conditioner for grid integration of wind generators', Ph. D. thesis, School of Electrical Engineering Systems, Dublin Institute of Technology, 2008